Australian bat lyssavirus (ABLV) is closely related to the classical rabies virus and has been associated with three human fatalities and two equine fatalities in Australia. ABLV infection in humans causes encephalomyelitis, resulting in fatal disease, but has no effective therapy. The virus is maintained in enzootic circulation within fruit bats (Pteropid spp.) and at least one insectivorous bat variety (Saccolaimus flaviventris). Most frequently, laboratory testing is conducted on pteropodid bat brains, either following a potential human exposure through bites, scratches and other direct contacts with bats, or as opportunistic assessment of sick or dead bats. The level of medical intervention and post-exposure prophylaxis is largely determined on laboratory testing for antigen/virus as the demonstrable infection status of the in-contact bat. This study evaluates the comparative diagnostic performance of a lateral flow test, Anigen Rabies Ag detection rapid test (RDT), in pteropodid variant of ABLV-infected bat brain tissues. The RDT demonstrated 100% agreement with the reference standard fluorescent antibody test on 43 clinical samples suggesting a potential application in rapid diagnosis of pteropodid variant of ABLV infection. A weighted Kappa value of 0.95 confirmed a high level of agreement between both tests.
Obtaining statistically sound numbers of sera from Hendra virus (HeV)-infected horses is problematic because affected individuals usually die or are euthanized before developing a serum antibody response. As a consequence, test validation becomes a challenge. Our approach is an extension of OIE principles for provisional recognition and included 7 validation panels tested across multiple laboratories that provided estimates for test performance characteristics. At a 0.4 S/P cutoff, 16 of 19 sera from HeV-infected horses gave positive results in the HeV soluble G, indirect ELISA (HeVsG iELISA; DSe 84.2% [95% CI: 60.4–96.6%]); 463 of 477 non-infected horse sera tested negative (DSp 97.1% [95% CI: 95.1–98.4%]). The HeVsG iELISA eliminated almost all false-positive results from the previously used HeV iELISA, with marginally decreased relative sensitivity. Assay robustness was evaluated in inter-laboratory and proficiency testing panels. The HeVsG iELISA is considered to be fit for purpose for serosurveillance and international movement of horses when virus neutralization is used for follow-up testing of positive or inconclusive serum samples.
Since the identification of Hendra virus (HeV) infections in horses in Australia in 1994, more than 80 outbreaks in horses have been reported, and four out of seven spillover infections in humans had a fatal outcome. With the availability of a subunit vaccine based on the HeV-Glycoprotein (HeV-G), there is a need to serologically Differentiate the Infected from the Vaccinated Animals (DIVA). We developed an indirect ELISA using HeV-G expressed in Leishmania tarentolae and HeV-Nucleoprotein (HeV-N) expressed in recombinant baculovirus-infected insect cells as antigens. During evaluation, we tested panels of sera from naïve, vaccinated and infected horses that either originated from a Hendra-virus free region, or had been pre-tested in validated diagnostic tests. Our data confirm the reliability of this approach, as HeV-N-specific antibodies were only detected in sera from infected horses, while HeV-G-specific antibodies were detected in infected and vaccinated horses with a high level of specificity and sensitivity. Given the excellent correlation of data obtained for German and Australian HeV-negative horses, we assume that this test can be applied for the testing of horse serum samples from a variety of geographical regions.
Hendra virus (HeV) is a bat-borne zoonotic agent which can cause a severe and highly fatal disease and can be transferred from animals to humans. It has caused over 100 deaths in horses since it was discovered in 1994. Four out of seven infected humans have died. Since the release of the HeV vaccine (Equivac® HeV Hendra Virus Vaccine for Horses, Zoetis Australia Pty Ltd., Rhodes, NSW 2138) in Australia, there has been an urgent requirement for a serological test for differentiating infected from vaccinated animals (DIVA). All first-line diagnostic serological assays at the Australian Centre for Disease Preparedness (ACDP) incorporate recombinant HeV soluble G glycoprotein (sG) as the antigen, which is also the only immunogen present in the Equivac® HeV vaccine. Problems therefore arose in that antibody testing results were unable to distinguish between prior vaccination or infection with HeV. This study describes the development of a HeV DIVA ELISA strategy using recombinant sG and HeV nucleoprotein (N), paired with specific monoclonal antibodies in a competition ELISA format. The validation of this assay strategy was performed using a positive cohort of 19 serum samples representing post-infection sera, a negative cohort of 1138 serum samples representing horse sera collected pre-vaccine release and a vaccination cohort of 502 serum samples from horses previously vaccinated with Equivac® HeV vaccine. For the sG glycoprotein, the diagnostic sensitivity (DSe) was 100.0% (95% CI: 99.3–100.0%) and diagnostic specificity (DSp) 99.91% (95% CI: 99.5–100.0%), using a percentage inhibition cut-off value of >36, whereas for the N protein, DSe was 100.0% (95% CI: 82.4–100.0%) and DSp 100.0% (95% CI: 99.7–100.0%), using a percentage inhibition cut-off value of >49. Taken together, these results demonstrate that the HeV DIVA ELISA strategy developed here is now an essential and critical component of the testing algorithm for HeV serology testing in Australia.