Background: To develop and validate a deep learning-based approach to the fully-automated analysis of macaque corneal sub-basal nerves using in vivo confocal microscopy (IVCM). Methods: IVCM was used to collect 108 images from 35 macaques. 58 of the images from 22 macaques were used to evaluate different deep convolutional neural network (CNN) architectures for the automatic analysis of sub-basal nerves relative to manual tracings. The remaining images were used to independently assess correlations and inter-observer performance relative to three readers. Results: Correlation scores using the coefficient of determination between readers and the best CNN averaged 0.80. For inter-observer comparison, inter-correlation coefficients (ICCs) between the three expert readers and the automated approach were 0.75, 0.85 and 0.92. The ICC between all four observers was 0.84, the same as the average between the CNN and individual readers. Conclusions: Deep learning-based segmentation of sub-basal nerves in IVCM images shows high to very high correlation to manual segmentations in macaque data and is indistinguishable across readers. As quantitative measurements of corneal sub-basal nerves are important biomarkers for disease screening and management, the reported work offers utility to a variety of research and clinical studies using IVCM.
Purpose: To evaluate the predictive ability of a deep learning-based algorithm to determine long-term best-corrected distance visual acuity (BCVA) outcomes in neovascular age-related macular degeneration (nARMD) patients using baseline swept-source optical coherence tomography (SS-OCT) and OCT-angiography (OCT-A) data. Methods: In this phase IV, retrospective, proof of concept, single center study, SS-OCT data from 17 previously treated nARMD eyes was used to assess retinal layer thicknesses, as well as quantify intraretinal fluid (IRF), subretinal fluid (SRF), and serous pigment epithelium detachments (PEDs) using a novel deep learning-based, macular fluid segmentation algorithm. Baseline OCT and OCT-A morphological features and fluid measurements were correlated using the Pearson correlation coefficient (PCC) to changes in BCVA from baseline to week 52. Results: Total retinal fluid (IRF, SRF and PED) volume at baseline had the strongest correlation to improvement in BCVA at month 12 (PCC = 0.652, p = 0.005). Fluid was subsequently sub-categorized into IRF, SRF and PED, with PED volume having the next highest correlation (PCC = 0.648, p = 0.005) to BCVA improvement. Average total retinal thickness in isolation demonstrated poor correlation (PCC = 0.334, p = 0.189). When two features, mean choroidal neovascular membranes (CNVM) size and total fluid volume, were combined and correlated with visual outcomes, the highest correlation increased to PCC = 0.695 (p = 0.002). Conclusions: In isolation, total fluid volume most closely correlates with change in BCVA values between baseline and week 52. In combination with complimentary information from OCT-A, an improvement in the linear correlation score was observed. Average total retinal thickness provided a lower correlation, and thus provides a lower predictive outcome than alternative metrics assessed. Clinically, a machine-learning approach to analyzing fluid metrics in combination with lesion size may provide an advantage in personalizing therapy and predicting BCVA outcomes at week 52.
An objective method of early identification of people at risk of chemotherapy-induced peripheral neuropathy is needed to minimize long-term toxicity and maximize dose intensity. The aims of the study were to observe corneal nerve microstructure and corneal sensitivity changes and peripheral neuropathy in patients receiving oxaliplatin, and to determine its association with corneal parameters at different stages of treatment and assess utility as non-invasive markers to detect and monitor peripheral neuropathy. Twenty-three patients scheduled to receive oxaliplatin chemotherapy with intravenous 5-FU for gastro-intestinal cancer were recruited and followed up with for 12 months. Ocular examinations including corneal and retinal evaluations, alongside peripheral neuropathy assessment, were performed. The corneal nerve density did not show significant change after chemotherapy when measured with a widely used semi-automated program or an automated analysis technique. Macula and optic nerve function did not change during or after oxaliplatin chemotherapy. However, the corneal nerve density modestly correlated with clinical peripheral neuropathy after 20 weeks of chemotherapy (r = 0.61, p = 0.01) when peripheral neuropathy is typical most profound, and corneal nerve sensitivity correlated with neuropathy at 12 (r = 0.55, p = 0.01) and 20 weeks (r = 0.64, p = 0.006). In conclusion, corneal changes detected on confocal microscopy show moderate association with peripheral neuropathy, indicating their potential to identify the development of oxaliplatin-induced peripheral neuropathy. However, further studies are required to confirm these findings.
31 August 2024 in American Journal of Ophthalmology
PURPOSE: This study aims to quantify the volume of intraretinal fluid (IRF), subretinal fluid (SRF), and sub- retinal pigment epithelium (sub-RPE) fluid in treatment- na & iuml;ve Type 3 macular neovascularization (MNV) eyes with age-related macular degeneration (AMD) and to investigate the correlation of these fluid volumes with visual acuity (VA) outcomes at baseline and following antivascular endothelial growth factor (VEGF) treatment. DESIGN: Retrospective, clinical cohort study. METHODS: In this study, we analyzed patients diagnosed with exudative AMD and treatment-na & iuml;ve Type 3 MNV undergoing a loading dose of anti-VEGF therapy. Using a validated deep-learning segmentation strategy, we processed optical coherence tomography (OCT) B-scans to segment and quantify IRF (i.e., both in the inner and outer retina), SRF, and sub-RPE fluid volumes at baseline. The study correlated baseline fluid volumes with baseline and short-term VA outcomes postloading dose of anti-VEGF injections. RESULTS: Forty-six eyes from 46 patients were included in this study. Visual acuity was 0.51 +/- 0.30 LogMAR at baseline and 0.33 +/- 0.20 LogMAR after the loading dose of anti-VEGF ( P = .001). Visual acuity at the follow-up visit was 0.40 +/- 0.17 LogMAR in patients with no complete resolution of retinal fluid and 0.31 +/- 0.20 LogMAR in eyes without retinal fluid after treatment ( P = .225). In the multivariable analysis, the IRF volume in the inner retina ( P = .032) and the distance of the MNV from the fovea ( P = .037) were predictors of visual acuity at baseline. The baseline IRF volume in the inner retina also predicted the visual acuity at follow-up ( P = .023). CONCLUSION: The present study highlights the fluid volume in the inner retina as a crucial predictor of shortterm visual outcomes in Type 3 MNV, underscoring the detrimental effect of IRF on neuroretinal structures. (Am J Ophthalmol 2025;269: 181-188. (c) 2024 Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.)
Purpose: To evaluate a prototype home optical coherence tomography device and automated analysis software for detection and quantification of retinal fluid relative to manual human grading in a cohort of patients with neovascular age-related macular degeneration. Methods: Patients undergoing anti-vascular endothelial growth factor therapy were enrolled in this prospective observational study. In 136 optical coherence tomography scans from 70 patients using the prototype home optical coherence tomography device, fluid segmentation was performed using automated analysis software and compared with manual gradings across all retinal fluid types using receiver-operating characteristic curves. The Dice similarity coefficient was used to assess the accuracy of segmentations, and correlation of fluid areas quantified end point agreement. Results: Fluid detection per B-scan had area under the receiver-operating characteristic curves of 0.95, 0.97, and 0.98 for intraretinal fluid, subretinal fluid, and subretinal pigment epithelium fluid, respectively. On a per volume basis, the values for intraretinal fluid, subretinal fluid, and subretinal pigment epithelium fluid were 0.997, 0.998, and 0.998, respectively. The average Dice similarity coefficient values across all B-scans were 0.64, 0.73, and 0.74, and the coefficients of determination were 0.81, 0.93, and 0.97 for intraretinal fluid, subretinal fluid, and subretinal pigment epithelium fluid, respectively. Conclusion: Home optical coherence tomography device images assessed using the automated analysis software showed excellent agreement to manual human grading.
Purpose: To evaluate the performance of a deep learning-based, fully automated, multi-class, macular fluid segmentation algorithm relative to expert annotations in a heterogeneous population of confirmed wet age-related macular degeneration (wAMD) subjects. Methods: Twenty-two swept-source optical coherence tomography (SS-OCT) volumes of the macula from 22 from different individuals with wAMD were manually annotated by two expert graders. These results were compared using cross-validation (CV) to automated segmentations using a deep learning-based algorithm encoding spatial information about retinal tissue as an additional input to the network. The algorithm detects and delineates fluid regions in the OCT data, differentiating between intra- and sub-retinal fluid (IRF, SRF), as well as fluid resulting from in serous pigment epithelial detachments (PED). Standard metrics for fluid detection and quantification were used to evaluate performance. Results: The per slice receiver operating characteristic (ROC) area under the curves (AUCs) for each of these fluid types were 0.90, 0.94 and 0.94 for IRF, SRF and PED, respectively. Per volume results were 0.94 and 0.88 for IRF and PED (SRF being present in all cases). The correlation of fluid volume between the expert graders and the algorithm were 0.99 for IRF, 0.99 for SRF and 0.82 for PED. Conclusions: Automated, deep learning-based segmentation is able to accurately detect and quantify different macular fluid types in SS-OCT data on par with expert graders.