Anju Toor

Dr. Anju Toor


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2018 in ACS Nano
Verified
Journal Article
Closed access
ATAnju Toor
Anju Toor
SLSean Lamb
Sean Lamb
BHBrett A. Helms
Brett A. Helms
TRThomas Paul Russell
Thomas Paul Russell


28 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
CBCarol Baumbauer
Carol Baumbauer
PGPayton J. Goodrich
Payton J. Goodrich
MPMargaret E. Payne
Margaret E. Payne
TATyler Anthony
Tyler Anthony
CBClaire Beckstoffer
Claire Beckstoffer
AAAna Claudia Arias
Ana Claudia Arias
Plant-available nitrogen, often in the form of nitrate, is an essential nutrient for plant growth. However, excessive nitrate in the environment and watershed has harmful impacts on natural ecosystems and consequently human health. A distributed network of nitrate sensors could help to quantify and monitor nitrogen in agriculture and the environment. Here, we have developed fully printed potentiometric nitrate sensors and characterized their sensitivity and selectivity to nitrate. Each sensor comprises an ion-selective electrode and a reference electrode that are functionalized with polymeric membranes. The sensitivity of the printed ion-selective electrodes was characterized by measuring their potential with respect to a commercial silver/silver chloride reference electrode in varying concentrations of nitrate solutions. The sensitivity of the printed reference electrodes to nitrate was minimized with a membrane containing polyvinyl butyral (PVB), sodium chloride, and sodium nitrate. Selectivity studies with sulphate, chloride, phosphate, nitrite, ammonium, calcium, potassium, and magnesium showed that high concentrations of calcium can influence sensor behavior. The printed ion-selective and reference electrodes were combined to form a fully printed sensor with sensitivity of −48.0 ± 3.3 mV/dec between 0.62 and 6200 ppm nitrate in solution and −47 ± 4.1 mV/dec in peat soil.

10 February 2017 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
ATAnju Toor
Anju Toor
Hongyun SoHongyun So
Hongyun So
APAlbert P. Pisano
Albert P. Pisano

1 October 2020 in APL Materials
Verified
Journal Article
Open access
PDF file
AZAlla M. Zamarayeva
Alla M. Zamarayeva
NYNatasha A. D. Yamamoto
Natasha A. D. Yamamoto
ATAnju Toor
Anju Toor
MPMargaret E. Payne
Margaret E. Payne
CWCaleb Woods
Caleb Woods
AAAna Claudia Arias
Ana Claudia Arias
We describe the optimization of a flexible printed electrochemical sensing platform to monitor sodium ion (Na+), ammonium ion (NH4+), and lactate in human sweat. We used previously reported material systems and adapted them to scalable fabrication techniques. In the case of potentiometric Na+ and NH4+ sensors, ion-selective electrodes (ISEs) required minimum optimization beyond previously reported protocols, while a reference electrode had to be modified in order to achieve a stable response. We incorporated a carbon nanotube (CNT) layer between the membrane and the silver/silver chloride (Ag/AgCl) layer to act as a surface for adsorption and retention of Cl−. The resulting reference electrode showed minimal potential variation up to 0.08 mV in the solutions with Cl concentration varying from 0.1 mM to 100 mM. Increasing the ionophore content in the NH4+ ISE sensing membrane eliminated an offset in the potential readout, while incorporating CNTs into the sensing membranes had a marginal effect on the sensitivity of both Na+ and NH4+ sensors. Na+ and NH4+ sensors showed a stable near-Nernstian response with sensitivities of 60.0 ± 4.0 mV and 56.2 ± 2.3 mV, respectively, long-term stability for at least 60 min of continuous operation, and selectivity to Na+ and NH4+. For the lactate sensor, we compared the performance of the tetrathiafulvalene mediated lactate oxidase based working electrode with and without diffusion-limiting polyvinyl chloride membrane. The working electrodes with and without the membrane showed sensitivities of 3.28 ± 8 A/mM and 0.43 ± 0.11 μA/mM with a linear range up to 20 mM and 30 mM lactate, respectively.

19 September 2019 in Langmuir
Verified
Journal Article
Closed access
ATAnju Toor
Anju Toor
JFJoe Forth
Joe Forth
SASimone Bochner de Araujo
Simone Bochner de Araujo
MMMaria Consiglia Merola
Maria Consiglia Merola
YJYufeng Jiang
Yufeng Jiang
TRThomas Paul Russell
Thomas Paul Russell