Abdullah Najib

Dr. Abdullah Najib


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FAFAHAD ALMEHMADI
FAHAD ALMEHMADI
ANAbdullah Najib
Abdullah Najib
EAEmad Ali
Emad Ali
HAHany Al-Ansary
Hany Al-Ansary
Jamel OrfiJamel Orfi
Jamel Orfi
Cogeneration of energy and clean water by incorporating direct contact membrane desalination (DCMD) and photovoltaic hybrid thermal system (PVT) into a residential building is a promising technology for addressing water and energy shortage in distant places. In this study, a microgrid integration between PVT, DCMD, and a residential building is proposed, with an end goal to meet partial electric load in the building and provide a clean water supply. A mathematical model was developed and validated to assess the system’s performance. Artificial Neural Network (ANN) and optimization techniques have been used. The performance of the proposed system was studied under the meteorological conditions of Riyadh, Saudi Arabia, and under several design and operation parameters. The optimal performance of the system is found as functions of the inlet brackish water temperature to the PVT, capital and installation cost, and the desired water productivity. Results reveal that the specific cost of water (SCW) is 23.6 $/m3 achieved with a renewable energy penetration of 25%, depending on the cost of PVT and electricity price. Thus, the proposed system meets 25% of the electric demand for the residential building, while the rest is imported from the grid. In addition, the proposed system reduced the annual greenhouse gas emission by 4300 kg for a single building. This study will contribute to a better understanding of incorporating innovative clean energy and water systems such as PVT and DCMD into a residential house.

27 May 2021 in Water
Verified
Journal Article
Open access
PDF file
ANAbdullah Najib
Abdullah Najib
Jamel OrfiJamel Orfi
Jamel Orfi
HAHany Al-Ansary
Hany Al-Ansary
EAEmad Ali
Emad Ali
A comprehensive study was conducted to elucidate the effect of operating conditions on the performance of a multi-effect vacuum membrane distillation pilot plant. A theoretical assessment of the energy and exergy efficiency of the process was achieved using a mathematical model based on heat and mass transfer, which was calibrated using experimental data obtained from the pilot plant. The pilot plant was a solar vacuum multi-effect membrane distillation (V-MEMD) module comprising five stages. It was found that a maximal permeate mass flux of 17.2 kg/m2·h, a recovery ratio of 47.6%, and a performance ratio of 5.38% may be achieved. The resulting gain output ratio (GOR) under these conditions was 5.05, which is comparable to previously reported values. Furthermore, the present work systematically evaluated not only the specific thermal energy consumption (STEC), but also the specific electrical energy consumption (SEEC), which has been generally neglected in previous studies. We show that STEC and SEEC may reach 166 kWh/m3 and 4.5 kWh/m3, respectively. We also observed that increasing the feed flow rate has a positive impact on the process performance, particularly when the feed temperature is higher than 65 °C. Under ideal operational conditions, the exergetic efficiency reached 21.1%, and the maximum fraction of exergy destruction was localized in the condenser compartment. Variation of the inlet hot and cold temperatures at a constant differential showed an interesting and variable impact on the performance indicators of the V-MEMD unit. The difference with the lowest inlet temperatures exhibited the most negative impact on the system performance.

13 February 2024 in Membranes
Verified
Journal Article
Open access
PDF file
ANAbdullah Najib
Abdullah Najib
TMTurki Mana
Turki Mana
EAEmad Ali
Emad Ali
HAHany Al-Ansary
Hany Al-Ansary
FAFAHAD ALMEHMADI
FAHAD ALMEHMADI
MAMansour Alhoshan
Mansour Alhoshan
This paper addresses a retrofitting vacuum membrane distillation (VMD) setup to reduce the accumulated pressure inside the permeated side. This modification is necessary to extend the operation of the VMD to extreme operation conditions of higher hot water temperatures. This modification, denoted as a hybrid configuration, proposes the injection of a cold water stream into the VMD cell without mixing it with the permeate. Energy and exergy efficiency analyses were performed to assess the effectiveness of the hybrid configuration. The performance of the modified system indicated an improvement in terms of permeate flux (J), the gain output ratio (GOR), and the utilitarian exergetic efficiency (ηex,u), which reach up to two and three times that of the base configuration of the VMD system. However, the exergetic efficiency (ηex) of the hybrid system showed marginal improvement compared to the base case over the tested range of hot water temperatures. This is because the enhanced vapor production is penalized by excess energy consumption. Moreover, the highest exergy destruction percentages occurred in the operational components (e.g., heater and chillers) which fall in the range of 19.0–68.9%. The exergy destruction percentage in the original components (e.g., the VMD cell and condenser) did not exceed 8.3%. Furthermore, this study indicated that the hybrid configuration requires additional tuning and optimization to perform efficiently over wide operating conditions.


21 June 2021 in Journal of Thermal Science and Engineering Applications
Verified
Journal Article
Closed access
PDF file
ANAbdullah Najib
Abdullah Najib
Jamel OrfiJamel Orfi
Jamel Orfi
HAHany Al-Ansary
Hany Al-Ansary
EAEmad Ali
Emad Ali
This study aims to develop a dimensionless model of the vacuum multi-effect membrane distillation (V-MEMD) system through which a preliminary prediction of the most critical performance indicators can be attained. The Buckingham Π theorem was utilized to define dimensionless parameters that enable the predicted relationships associated with independent input parameters to describe the essential performance indicators of the V-MEMD system. The obtained simplified model reduces the design parameters from ten to two effective dimensionless parameters to realize the realistic and actual behavior of the designated system. The self-sustained model can be used as a short-cut tool for design and performance analysis to avoid time-consuming experimentations and complicated theoretical models. The compatibility of the generated model is assessed by matching the expected response of the output dimensionless parameters of recovery ratio (Π6) and gain output ratio (GOR, Π12) to variations in the pressure ratio and cooling process. The model is validated with other works, and discrepancies are found to be within ±8% and ±0.8 for the recovery ratio and GOR, respectively. Furthermore, the specific thermal energy consumption (STEC) is correlated to the GOR assuming constant vaporization enthalpy and density of the distillate water. The correlation can predict STEC within 5% accuracy over various operating conditions for the supplied hot water.

30 April 2022 in Membranes
Verified
Journal Article
Open access
PDF file
ANAbdullah Najib
Abdullah Najib
HAHany Al-Ansary
Hany Al-Ansary
Jamel OrfiJamel Orfi
Jamel Orfi
EAEmad Ali
Emad Ali
FAFAHAD ALMEHMADI
FAHAD ALMEHMADI
This work addresses retrofitting the infrastructure of multiple-effect vacuum membrane distillation (V-MEMD) units by using cross-flow configuration (CFC). In this configuration, the feed water is evenly divided and distributed over the effects. In this case, the feed water stream for each effect is kept at a high temperature and low flow rate. This will lead to an increase in the vapor pressure gradient across the hydrophobic membrane and can also maintain the thermal energy of the stream inside the individual effect. It is found that CFC improves internal and global performance indicators of productivity, energy, and exergy. A mathematical model was used to investigate the performance of such a modification as compared to the forward-flow configuration (FFC). The cross-flow configuration led to a clear improvement in the internal performance indicators of the V-MEMD unit, where specifically the mass flux, recovery ratio, gain output ratio, and heat recovery factor were increased by 2 to 3 folds. Moreover, all the global performance indicators were also enhanced by almost 2 folds, except for the performance indicators related to the heat pump, which is used to cool the cold water during the operation of the V-MEMD unit. For the heat pump system, the specific electrical energy consumption, SEEC, and the exergy destruction percentage, Ψdes, under the best-operating conditions, were inferior when the feed water flow was less than 159 L/h. This can be attributed to the fact that the heat rejected from the heat pump system is not fully harnessed.