Olaf Wilke

Dr. Olaf Wilke

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2004 in Indoor Air
Verified
Journal Article
Closed access
PDF file
OWOlaf Wilke
Olaf Wilke
OJOliver Jann
Oliver Jann
DBDoris Brodner
Doris Brodner
Emissions of volatile organic compounds (VOC) and semivolatile organic compounds (SVOC) from materials for flooring installation (primer, screed, adhesive, floor covering) were measured by means of emission test chambers and cells over a time period of at least 28 days at 23 degrees C, 50% relative humidity and an area specific air flow rate of q = 1.25 m(3)/m(2) h. Single components were tested in comparison to three complete structures (same concrete, primer, screed, adhesive) with different types of floor covering (PVC, carpet, linoleum). Sorption into concrete/screed and different permeability of flooring materials affected the emissions from the complete structures. The complete structures with linoleum and PVC showed the same types of emission and emission rates as the individual floor coverings themselves. Emissions from the carpet-covered structure resulted also from the lower layers. In all cases emissions from the complete structures were lower than the sum of emissions from the single components. For two adhesives the formation of secondary emissions (aldehydes and organic acids) was observed starting after the standard testing time of 28 days. This paper gives a survey of possible emissions of VOCs and SVOCs from flooring materials and adhesives. On the example of these materials it is shown that the determination of SVOC-emissions from materials is important because after a few weeks the emission rates for SVOCs might be higher than for VOCs. In the real indoor environment SVOCs will be probably adsorbed to dust but by means of emission test chambers or cells the determination of emission rates from materials is possible. With the knowledge of this "emission potential" it is possible to estimate also the release of SVOCs into the (indoor) environment.

25 January 2017 in Environments
Verified
Journal Article
Open access
PDF file
BMBirte Mull
Birte Mull
LMLennart Möhlmann
Lennart Möhlmann
OWOlaf Wilke
Olaf Wilke
Photocatalysis is a promising technique to reduce volatile organic compounds indoors. Titanium dioxide (TiO2) is a frequently-used UV active photocatalyst. Because of the lack of UV light indoors, TiO2 has to be modified to get its working range shifted into the visible light spectrum. In this study, the photocatalytic degradation of toluene, butyl acetate and limonene was investigated under UV LED light and blue LED light in emission test chambers with catalysts either made of pure TiO2 or TiO2 modified with graphene oxide (GO). TiO2 coated with different GO amounts (0.75%–14%) were investigated to find an optimum ratio for the photocatalytic degradation of VOC in real indoor air concentrations. Most experiments were performed at a relative humidity of 0% in 20 L emission test chambers. Experiments at 40% relative humidity were done in a 1 m³ emission test chamber to determine potential byproducts. Degradation under UV LED light could be achieved for all three compounds with almost all tested catalyst samples up to more than 95%. Limonene had the highest degradation of the three selected volatile organic compounds under blue LED light with all investigated catalyst samples.

7 January 2021 in Materials
Verified
Journal Article
Open access
PDF file
MEMorgane Even
Morgane Even
OWOlaf Wilke
Olaf Wilke
SKSabine Kalus
Sabine Kalus
PSPetra Schultes
Petra Schultes
CHChristoph Hutzler
Christoph Hutzler
ALAndreas Luch
Andreas Luch
Formaldehyde is considered as carcinogenic and is emitted from particleboards and plywood used in toy manufacturing. Currently, the flask method is frequently used in Europe for market surveillance purposes to assess formaldehyde release from toys, but its concordance to levels measured in emission test chambers is poor. Surveillance laboratories are unable to afford laborious and expensive emission chamber testing to comply with a new amendment of the European Toy Directive; they need an alternative method that can provide reliable results. Therefore, the application of miniaturised emission test chambers was tested. Comparisons between a 1 m3 emission test chamber and 44 mL microchambers with two particleboards over 28 days and between a 24 L desiccator chamber and the microchambers with three puzzle samples over 10 days resulted in a correlation coefficient r2 of 0.834 for formaldehyde at steady state. The correlation between the results obtained in microchambers vs. flask showed a high variability over 10 samples (r2: 0.145), thereby demonstrating the error-proneness of the flask method in comparison to methods carried out under ambient parameters. An exposure assessment was also performed for three toy puzzles: indoor formaldehyde concentrations caused by puzzles were not negligible (up to 8 µg/m3), especially when more conservative exposure scenarios were considered.

3 May 2021 in Indoor Air
Verified
Journal Article
Open access
PDF file
OWOlaf Wilke
Olaf Wilke
WHWolfgang Horn
Wolfgang Horn
MRMatthias Richter
Matthias Richter
OJOliver Jann
Oliver Jann
Emission testing of volatile organic compounds (VOC) from materials and products is commonly based on emission test chamber measurements. To ensure the comparability of results from different testing laboratories, their measurement performance must be verified. For this purpose, Bundesanstalt für Materialforschung und ‐prüfung (BAM) organizes an international proficiency test (round robin test, RRT) every two years using well‐characterized test materials (one sealant, one furniture board, and four times a lacquer) with defined VOC emissions. The materials fulfilled the requirements of homogeneity, reproducibility, and stability. Altogether, 36 VOCs were included of which 33 gave test chamber air concentrations between 13 and 83 µg/m3. This is the typical concentration range to be expected and to be quantified when performing chamber tests. Three compounds had higher concentrations between 326 and 1105 µg/m3. In this paper, the relative standard deviations (RSD) of BAM round robin tests since 2008 are compared and the improvement of the comparability of the emission chamber testing is shown by the decrease of the mean RSD down to 28% in 2018. In contrast, the first large European interlaboratory comparison in 1999 showed a mean RSD of 51%.

20 September 2013 in Indoor and Built Environment
Verified
Journal Article
Closed access
OWOlaf Wilke
Olaf Wilke
KWKatharina Wiegner
Katharina Wiegner
HSHarald Scheffer
Harald Scheffer
DBDoris Brödner
Doris Brödner
SKSabine Kalus
Sabine Kalus
There has been an increasing use of oriented strand boards (OSBs) for the construction of floors, ceilings and walls of buildings. In Germany and other European countries, OSBs are mainly produced from pine wood (Pinus sylvestris). In response to complaints about the odour and irritation of mucous membranes in connection with the use of OSBs, samples of OSBs were bought from do-it-yourself stores to test their volatile organic compound (VOC) emissions by using emission test chambers. The boards emitted predominantly monoterpenes, aldehydes, acids and acetone. Aldehydes are generated during the production process by the oxidation of unsaturated fatty acids such as linoleic acid. Pine wood, compared with other wood species, contains more unsaturated fatty acids. Of the six acquired OSBs, four boards from three manufacturers would not meet the requirements of the German AgBB (Ausschuss zur gesundheitlichen Bewertung von Bauprodukten, Committee for Health Evaluation of Building Products), mainly because of the emissions of unsaturated aldehydes. These compounds have low LCI values (lowest concentration of interest) and are therefore problematic substances based on a health-related evaluation of building products according to the AgBB scheme.

19 December 2022 in Measurement Science and Technology
Verified
Journal Article
Open access
PDF file
IKIris de Krom
Iris de Krom
DHDita Heikens
Dita Heikens
WHWolfgang Horn
Wolfgang Horn
OWOlaf Wilke
Olaf Wilke
MRMatthias Richter
Matthias Richter
ABAnnarita Baldan
Annarita Baldan
EN 16516 sets specifications for the determination of emissions into indoor air from construction products. Reliable, accurate and International System of Unit (SI)-traceable measurement results of the emissions are the key to consumer protection. Such measurement results can be obtained by using metrologically traceable reference materials. Gas-phase standards of volatile organic compounds (VOCs) in air can be prepared by a variety of dynamic methods according to the ISO 6145 series. However, these methods are not always applicable for semi-VOCs (SVOCs) due to their high boiling point and low vapour pressure. Therefore, a novel dynamic gas mixture generation system has been developed. With this system gas-phase standards with trace level VOCs and SVOCs in air can be prepared between 10 nmol mol−1 and 1000 nmol mol−1. The VOCs and SVOCs in this study have normal boiling points ranging from 146 °C to 343 °C. Metrologically traceable reference materials of the gas-phase standard were obtained by sampling of the VOC gas-phase standard into Tenax TA® sorbent material in SilcoNert® coated stainless steel tubes. Accurately known masses between 10 ng and 1000 ng per VOC were sampled. These reference materials were used to validate the dynamic system. Furthermore, the storage and stability periods of the VOCs in the reference materials were determined as these are crucial characteristics to obtain accurate and SI-traceable reference materials. In a round robin test (RRT), the reference materials were used with the aim of demonstrating the feasibility of providing SI-traceable standard reference values for SVOCs for interlaboratory comparison purposes. Based on the results from the validation, the storage and stability studies and the RRT, gas-phase standards and reference materials of VOCs and SVOCs with relative expanded uncertainties between 5% and 12% (k = 2) have been developed. These reference standards can be used as calibrants, reference materials or quality control materials for the analysis of VOC emissions.