Ewan Mark Brownlee

Mr. Ewan Mark Brownlee

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2022 in Children
Verified
Journal Article
Open access
PDF file
EBEwan Mark Brownlee
Ewan Mark Brownlee
DSDr Mark Slack - Chief Medical Officer, CMR Surgical
Dr Mark Slack - Chief Medical Officer, CMR Surgical
The uptake of robot-assisted surgery has continuously grown since its advent in the 1990s. While robot-assisted surgery is well-established in adult surgery, the rate of uptake in paediatric surgical centres has been slower. The advantages of a robot-assisted system, such as improved visibility, dexterity, and ergonomics, could make it a superior choice over the traditional laparoscopic approach. However, its implementation in the paediatric surgery arena has been limited primarily due to the unavailability of appropriately sized instruments as per paediatric body habitus, therefore, requiring more technologically advanced systems. The Versius surgical robotic system is a new modular platform that offers several benefits such as articulated instruments which pass through conventional 5 mm ports, compact arms for easier manoeuvrability and patient access, the ability to mimic conventional port placements, and adaptive machine learning concepts. Prior to its introduction to paediatric surgery, it needs to go through a careful pre-clinical and clinical research program.

3 May 2023 in Children
Verified
Journal Article
Open access
PDF file
Thomas Franz KrebsThomas Franz Krebs
Thomas Franz Krebs
TKTimo Kayser
Timo Kayser
ULUlf Lorenzen
Ulf Lorenzen
MGMatthias Grünewald
Matthias Grünewald
MKMarit Kayser
Marit Kayser
Robert BergholzRobert Bergholz
Robert Bergholz
Background: We were able to demonstrate the feasibility of a new robotic system (Versius, CMR Surgical, Cambridge, UK) for procedures in small inanimate cavities. The aim of this consecutive study was to test the Versius® system for its feasibility, performance, and safety of robotic abdominal and thoracic surgery in piglets simulating infants with a body weight lower than 10 kg. Methods: A total of 24 procedures (from explorative laparoscopy to thoracoscopic esophageal repair) were performed in 4 piglets with a mean age of 12 days and a mean body weight of 6.4 (7–7.5) kg. Additional urological procedures were performed after euthanasia of the piglet. The Versius® robotic system was used with 5 mm wristed instruments and a 10 mm 3D 0° or 30° camera. The setup consisted of the master console and three to four separate arms. The performance of the procedure, the size, position, and the distance between the ports, the external and internal collisions, and complications of the procedures were recorded and analyzed. Results: We were able to perform all surgical procedures as planned. We encountered neither surgical nor robot-associated complications in the live model. Whereas all abdominal procedures could be performed successfully under general anesthesia, one piglet was euthanized early before the thoracic interventions, likely due to pulmonary inflammatory response. Technical limitations were based on the size of the camera (10 mm) being too large and the minimal insertion depth of the instruments for calibration of the fulcrum point. Conclusions: Robotic surgery on newborns and infants appears technically feasible with the Versius® system. Software adjustments for fulcrum point calibration need to be implemented by the manufacturer as a result of our study. To further evaluate the Versius® system, prospective trials are needed, comparing it to open and laparoscopic surgery as well as to other robotic systems.

1 April 2022 in Journal of Pediatric Urology
Verified
Journal Article
Closed access
SWSimon Wong
Simon Wong
GVGanesh Vigneswaran
Ganesh Vigneswaran
DMDrew Maclean
Drew Maclean
TBTimothy Bryant
Timothy Bryant
NHNigel Hacking
Nigel Hacking
SMSachin Modi
Sachin Modi

1 January 2009 in Medical Equipment Insights
Verified
Journal Article
Open access
EMEuan R. MacDonald
Euan R. MacDonald
EBEwan Mark Brownlee
Ewan Mark Brownlee
IAIrfan Ahmed
Irfan Ahmed
Single port transumbilical laparoscopic surgery (LESS, SILS, ENOTES) is a technique which has recently emerged with a view to improving the cosmesis following minimal access surgery, aiming to achieve ‘scarless’ surgery. This rapidly progressing technique is facilitated by developments in port and instrument technology, allowing surgeons to perform a wider range of surgical procedures with increasing ease. This paper aims to summarise the equipment available at present for single port surgery.

10 August 2026 in Journal of Pediatric Surgery
Verified
Journal Article
Open access
MFMatthew Formstone
Matthew Formstone
GBGeorge Bethell
George Bethell
SMSengamalai Manoharan
Sengamalai Manoharan
SGStephen Griffin
Stephen Griffin
EBEwan Mark Brownlee
Ewan Mark Brownlee
RCRosie Cresner
Rosie Cresner
Multiple endoscopic treatments for vesicoureteral junction obstruction (VUJO) in children with primary obstructive megaureter (POM) have been described, but their relative effectiveness remains unclear. This systematic review aimed to evaluate the efficacy, safety, and reported outcomes of these techniques. A systematic review of MEDLINE via PubMed, Embase, and the Cochrane Library was performed in accordance with PRISMA guidelines (PROSPERO: CRD42024536020). Studies reporting outcomes of endoscopic treatment of VUJO in children were included. The primary outcome was treatment success according to each study's prespecified definition. Procedural success was analyzed separately as a secondary technical feasibility outcome. Risk of bias was assessed using ROBINS-I. Random-effects meta-analysis of proportions was performed where outcome definitions were comparable. Twenty-seven studies, including 789 children and 816 renal units, were included. Seven endoscopic strategies were identified. Reported treatment success ranged from 26% to 100%, with nine different definitions identified. Post-operative ureteric reimplantation was most frequent after stenting alone (53.7%), compared with 2.1%-20% across distal ureter-modifying techniques. Balloon dilatation with stenting was the most frequently reported technique (16 studies). Meta-analysis showed definition-specific pooled treatment success ranging from 0.84 to 0.95 for balloon dilatation with stenting and from 0.91 to 1.00 for VUJ incision with stenting, with low statistical heterogeneity in each analysis. Reported complications were mainly stent-related. Certain endoscopic techniques appear effective in selected children with POM. However, substantial heterogeneity in outcome definitions, study design, subgroup reporting, and follow-up limits direct comparison between techniques. Development of a core outcome set would improve future comparative research.

15 October 2026 in Journal of Pediatric Urology
Verified
Journal Article
Closed access
PGPatrick Green
Patrick Green
DKDavid Keene
David Keene
TCTamas Cserni
Tamas Cserni
AGAnju Goyal
Anju Goyal
PMPankaj Mishra
Pankaj Mishra
EBEwan Mark Brownlee
Ewan Mark Brownlee