Purpose: The blood-brain barrier (BBB) limits the efficacy of drug therapies for glioblastoma (GBM). Pre-clinical data indicate that low-intensity pulsed ultrasound (LIPU) can transiently disrupt the BBB and increase intracerebral drug concentrations. Experimental Design: A first-in-man, single-arm, single-center trial (NCT02253212) was initiated to investigate the transient disruption of the BBB in patients with recurrent glioblastoma (rGBM). Patients were implanted with a 1 MHz, 11.5-mm diameter cranial ultrasound device (SonoCloud-1, CarThera, Paris, France). The device was activated monthly to transiently disrupt the BBB before intravenous (IV) carboplatin chemotherapy. Results: Between 2014 and 2016, 21 patients were registered for the study and implanted with the SonoCloud-1; 19 patients received at least one sonication. In 65 US sessions, BBB disruption was visible on T1w MRI for 52 sonications. Treatment-related adverse events observed were transient and manageable: a transient edema at H1 and at D15. No carboplatin-related neurotoxicity was observed. Patients with no or poor BBB disruption (n=8) visible on MRI had a median progression-free survival (PFS) of 2.73 months, and a median overall survival (OS) of 8.64 months. Patients with clear BBB disruption (n=11) had a median PFS of 4.11 months, and a median OS of 12.94 months. Conclusions:SonoCloud-1 treatments were well tolerated and may increase the effectiveness of systemic drug therapies, such as carboplatin, in the brain without inducing neurotoxicity.
1 October 2005 in Ultrasound in Medicine & Biology
OBJECTIVE: The main limitation to the efficacy of chemotherapy for brain tumors is the restricted access to the brain because of the limited permeability of the blood-brain barrier (BBB). Previous animal studies have shown that the application of pulsed ultrasound (US), in combination with the intravenous injection of microbubbles, can temporarily disrupt the BBB to deliver drugs that normally cannot reach brain tissue. Although many previous studies have been performed with external focused US transducers, the device described in the current work emits US energy using an unfocused transducer implanted in the skull thickness. This method avoids distortion of the US energy by the skull bone and allows for simple, repetitive, and broad disruption of the BBB without the need for MRI monitoring. The purpose of the present study was to determine if the BBB can be safely and repeatedly disrupted using such an implantable unfocused US device in a primate model. METHODS: An 11.5-mm-diameter, 1-MHz, planar US device was implanted via a bur hole into the skull of 3 primates (2 Papio anubis [olive] baboons and 1 Macaca fascicularis [macaque]) for 4 months. Pulsed US sonications were applied together with the simultaneous intravenous injection of sulfur hexafluoride microbubbles (SonoVue) every 2 weeks to temporarily disrupt the BBB. In each primate, a total of 7 sonications were performed with a 23.2-msec burst length (25,000 cycles) and a 1-Hz pulse repetition frequency at acoustic pressure levels of 0.6–0.8 MPa. Potential toxicity induced by repeated BBB opening was analyzed using MRI, PET, electroencephalography (EEG), somatosensory evoked potential (SSEP) monitoring, behavioral scales, and histopathological analysis. RESULTS: The T1-weighted contrast-enhanced MR images acquired after each sonication exhibited a zone of hypersignal underneath the transducer that persisted for more than 4 hours, indicating a broad region of BBB opening in the acoustic field of the implant. Positron emission tomography images with fluorine-18–labeled fluorodeoxyglucose (FDG) did not indicate any changes in the cerebral metabolism of glucose. Neither epileptic signs nor pathological central nerve conduction was observed on EEG and SSEP recordings, respectively. Behavior in all animals remained normal. Histological analysis showed no hemorrhagic processes, no petechia, and extravasation of only a few erythrocytes. CONCLUSIONS: The studies performed confirm that an implantable, 1-MHz US device can be used to repeatedly open the BBB broadly in a large-animal model without inducing any acute, subacute, or chronic lesions.
1 November 2011 in Investigative Ophthalmology & Visual Science
Purpose.: To evaluate the relative safety and potential efficacy of high-intensity focused ultrasound cyclocoagulation by a miniaturized annular device containing six piezoceramic transducers in patients with refractory glaucoma. Methods.: This was a three-center prospective interventional pilot study. Twelve eyes of 12 patients with refractory glaucoma were insonified using a ring-shaped probe containing six miniaturized high-frequency transducers operating at 21 MHz. Ultrasound biomicroscopy (UBM) and a complete ophthalmic examination were performed before the procedure and at 1 day, 1 week, 1 month, and 3 months after the procedure. Additional visits were performed 6 and 12 months after the procedure. Results.: Intraocular pressure was significantly reduced (P < 0.01) from a mean preoperative value of 37.9 ± 10.7 mm Hg to a mean postoperative value of 27.3 ± 12.4, 25.2 ± 11.3, 25.2 ± 7.7, 24.8 ± 9.8, and 26.3 ± 5.1 mm Hg at 1 day, 1 week, 1 month, 3 months, and 6 months, respectively, and to a mean value of 24.7 ± 8.5 at the last follow-up visit. No major intraoperative or postoperative complications occurred. Minor postoperative corneal complications developed in four patients with previous corneal abnormalities: superficial punctate keratitis (n = 3) and central superficial corneal ulceration (n = 1). UBM showed cystic involution of the ciliary body in 9 of the 12 eyes and a suprachoroidal fluid space in 8 of the 12 eyes. Conclusions.: Ultrasonic circular cyclocoagulation using high-intensity focused ultrasound delivered by a circular miniaturized device containing six piezoceramic transducers seems to be an effective and well-tolerated method to reduce intraocular pressure in patients with refractory glaucoma.
1 February 2005 in Ultrasound in Medicine & Biology