Oleksandr Zabolotnyi

Dr. Oleksandr Zabolotnyi

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

7 July 2022 in Computation
Verified
Journal Article
Open access
PDF file
OZOleksandr Zabolotnyi
Oleksandr Zabolotnyi
VZVitalii Zabolotnyi
Vitalii Zabolotnyi
NKNikolay Koshevoy
Nikolay Koshevoy
The water content in fuel–water emulsions can vary from 10% to 30%, and is under control during the process of emulsification. The main task of this study was to obtain near-linear static function for a water-cut meter with capacitive sensors, and to provide it with effective type-uncertainty compensation during the process of water–fuel emulsion moisture control. To fulfill the capacitive measurements, two capacitive sensors in the measuring channel and two capacitive sensors in the reference channel were used. The method of least squares and general linear regression instruments were used to obtain robust and near-linear transfer function of the capacitive water-cut meter. The prototype product of the water-cut meter was developed with the purpose of fulfilling multiple moisture measurements and checking the workability of the new transfer function. Values of moisture content for the new transfer function and the closest analog were compared with the help of dispersion analysis. The new transfer function provided minimal dispersions of repeatability and adequacy, and minimal F-test values, proving its better capability for type-uncertainty compensation and better adequacy for the nominal linear transfer function of the water-cut meter.

1 January 2018 in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
Verified
Journal Article
Closed access
OZOleksandr Zabolotnyi
Oleksandr Zabolotnyi
VZV.A. Zabolotnyi
V.A. Zabolotnyi
KOKoshevoi
Koshevoi
Conditionality examination of the new testing algorithms for coal-water slurries moisture measurement



16 April 2019 in Radio Electronics, Computer Science, Control
Verified
Journal Article
Open access
PDF file
OZOleksandr Zabolotnyi
Oleksandr Zabolotnyi
Contest. Variable chemical composition of the materials under research is a reason for so-called “type uncertainty” appearance, because the result of moisture measurement strongly depends from initial dielectric permittivity (type) of a material, and dielectric permittivity can be significantly different not only for different materials, but for different varieties of the same material. Development of new and modification of existing moisture measurement methods and development of new instrumental and secondary transducers is a problem of current importance for increasing the accuracy of moisture measurement. Objective. The purpose of this work is reduction the error of moisture measurement for bulk and liquid materials by new methods and means of moisture measurement development. Methods. A new method of moisture measurement had been developed with two additive, two multiplicative and two complementary testing influences on the sample under research. It foresees getting seven readings of a capacitance that should be plugged into the formula of a testing algorithm to get the moisture value. The method allowed to reduce material’s type influence on the result of moisture measurement and to increase accuracy of measurements. To make a new method of moisture measurement proximate, special instrument transducer had been developed. It allows simulation of additive testing influences on the material by using flat conductive plates of a certain thickness, introduced directly into a space between the electrodes. Results. The main purpose of experiments was to prove the capability of the new method of moisture measurement to work with experimental values of capacitances. New instrument and secondary transducers had been developed for that purposes. Obtained results helped to see that new testing algorithm has good conditionality when working with real values of capacitances with natural random variation. Conclusions. As a result we could see that maximal absolute error does not overcome 1.3 % of moisture content. It shows that substitution the direct adding of water with metallic plates does not decrease conditionality of calculated moisture value results, obtained using the new method of moisture measurement.