Christian Jörg Rustenbach

Dr. Christian Jörg Rustenbach

University Hospital Tuebingen, Tübingen, Baden-Württemberg, Germany
+1
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2018 in Heart
Verified
Journal Article
Closed access
PDF file
SBSabine Bleiziffer
Sabine Bleiziffer
MEMagdalena Erlebach
Magdalena Erlebach
MSMatheus Simonato
Matheus Simonato
PPPhilippe Pibarot
Philippe Pibarot
JWJohn Webb
John Webb
DDDanny Dvir
Danny Dvir
Objective We aimed to analyse the incidence of prosthesis–patient mismatch (PPM) and elevated gradients after aortic valve in valve (ViV), and to evaluate predictors and associations with clinical outcomes of this adverse event. Methods A total of 910 aortic ViV patients were investigated. Elevated residual gradients were defined as ≥20 mm Hg. PPM was identified based on the indexed effective orifice area (EOA), measured by echocardiography, and patient body mass index (BMI). Moderate and severe PPM (cases) were defined by European Association of Cardiovascular Imaging (EACVI) criteria and compared with patients without PPM (controls). Results Moderate or greater PPM was found in 61% of the patients, and severe in 24.6%. Elevated residual gradients were found in 27.9%. Independent risk factors for the occurrence of lower indexed EOA and therefore severe PPM were higher gradients of the failed bioprosthesis at baseline (unstandardised beta −0.023; 95% CI −0.032 to –0.014; P<0.001), a stented (vs a stentless) surgical bioprosthesis (unstandardised beta −0.11; 95% CI −0.161 to –0.071; P<0.001), higher BMI (unstandardised beta −0.01; 95% CI −0.013 to –0.007; P<0.001) and implantation of a SAPIEN/SAPIEN XT/SAPIEN 3 transcatheter device (unstandardised beta −0.064; 95% CI −0.095 to –0.032; P<0.001). Neither severe PPM nor elevated gradients had an association with VARC II-defined outcomes or 1-year survival (90.9% severe vs 91.5% moderate vs 89.3% none, P=0.44). Conclusions Severe PPM and elevated gradients after aortic ViV are very common but were not associated with short-term survival and clinical outcomes. The long-term effect of poor post-ViV haemodynamics on clinical outcomes requires further evaluation.

1 July 2016 in The Annals of Thoracic Surgery
Verified
Journal Article
Closed access
HBHardy Baumbach
Hardy Baumbach
Christian Jörg RustenbachChristian Jörg Rustenbach
Christian Jörg Rustenbach
SASamir Ahad
Samir Ahad
RNRagi Nagib
Ragi Nagib
MAMarc Albert
Marc Albert
UFUlrich F.W. Franke
Ulrich F.W. Franke

29 March 2020 in Journal of Cardiac Surgery
Verified
Journal Article
Open access
PDF file
Ilija DjordjevicIlija Djordjevic
Ilija Djordjevic
KEKaveh Eghbalzadeh
Kaveh Eghbalzadeh
ASAnton Sabashnikov
Anton Sabashnikov
ADAntje‐Christin Deppe
Antje‐Christin Deppe
EKElmar Kuhn
Elmar Kuhn
TWThorsten Wahlers
Thorsten Wahlers
Objectives Central or peripheral venoarterial extracorporeal membrane oxygenation (va ECMO) is widely used in postcardiotomy cardiogenic shock (PCS). Available data suggest controversial results for both types. Our aim was to investigate PCS patients treated with either peripheral (pECMO) or central ECMO (cECMO) concerning their outcome. Methods Between April 2006 and October 2016, 156 consecutive patients with va ECMO therapy due to PCS were identified and included in this retrospective analysis. Patients were divided into cECMO and pECMO groups. Statistical analysis of risk factors concerning 30‐day mortality of the mentioned patient cohort was performed using IBM SPSS Statistics. Results Fifty‐six patients received cECMO and 100 patients were treated with pECMO due to PCS. In the group of cECMO peripheral vascular disease was significantly more present (cECMO 19 [34%] vs pECMO 14 [14%]; P < .01). On‐site ECMO complications occurred significantly more frequent in patients treated with cECMO (cECMO 44 [79%] vs pECMO 54 [54%] g/dL; P < 0.01). More often cECMO patients required a second look operation due to mediastinal bleeding (cECMO 52 [93%] vs pECMO 61 [61%] g/dL; P < .01). Thirty‐day mortality was comparable with nearly 70% in both cohorts (cECMO 39 [70%] vs pECMO 69 [69%]; P = .93). Conclusion Patients supported by cECMO or pECMO due to refractory PCS did not show significant differences in 30‐day mortality, despite a lower incidence of on‐site ECMO complications and re‐exploration in pECMO patients. PCS itself is associated with high mortality and peripheral cannulation might help to save resources compared with central cannulation.

25 July 2018 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
MKMarkus Kofler
Markus Kofler
SRSebastian J Reinstadler
Sebastian J Reinstadler
AMAgnes Mayr
Agnes Mayr
LSLukas Stastny
Lukas Stastny
MRMartin Reindl
Martin Reindl
Nikolaos BonarosNikolaos Bonaros
Nikolaos Bonaros
This study sought to assess the incremental prognostic value of the psoas muscle area in patients scheduled for transcatheter aortic valve implantation (TAVI). A total of 1076 consecutive patients undergoing TAVI at 2 centres between 2010 and 2017 were prospectively included in this study. Computed tomography-derived cross-sectional area of the psoas muscle was measured at the superior border of the third (L3) and fourth (L4) lumbar vertebra and indexed to body surface area (PMAi) as well as stratified into tertiles. Multivariable logistic regression and Cox regression analyses were performed to investigate the value of PMAi as a predictor of 30-day and cumulative mortality. The incremental prognostic value of PMAi over the Society of Thoracic Surgeons (STS) score was assessed using a net reclassification analysis. The rate of 30-day mortality was 5.8% (n = 62). PMAi at the level of L3 [odds ratio 0.082, 95% confidence interval (CI) 0.011-0.589; P = 0.013] and L4 (odds ratio 0.049, 95% CI 0.005-0.536; P = 0.013) was independently associated with 30-day mortality. During a median follow-up of 435 days (interquartile range 139-904), 292 patients (27.1%) died. PMAi of L3 (hazard ratio 0.200, 95% CI 0.083-0.482; P < 0.001) and L4 (hazard ratio 0.083, 95% CI 0.029-0.235; P < 0.001) was independently associated with mortality during follow-up. The addition of PMAi to the STS score led to a net reclassification improvement for 30-day and cumulative mortality. PMAi emerged as a valuable outcome predictor in patients undergoing TAVI. The addition of PMAi to the established STS score led to an increase in its prognostic ability.

1 October 2021 in Heart, Lung and Circulation
Verified
Journal Article
Closed access
Ilija DjordjevicIlija Djordjevic
Ilija Djordjevic
ADAntje-Christin Deppe
Antje-Christin Deppe
ASAnton Sabashnikov
Anton Sabashnikov
EKElmar Kuhn
Elmar Kuhn
Kaveh EghbalzadehKaveh Eghbalzadeh
Kaveh Eghbalzadeh
TWThorsten Wahlers
Thorsten Wahlers

28 February 2018 in The Thoracic and Cardiovascular Surgeon
Verified
Journal Article
Closed access
PDF file
KWKristina Wachter
Kristina Wachter
UFUlrich F.W. Franke
Ulrich F.W. Franke
Christian Jörg RustenbachChristian Jörg Rustenbach
Christian Jörg Rustenbach
HBHardy Baumbach
Hardy Baumbach
This review aims to provide an overview on recent data to evaluate minimally invasive (MVAD) and conventional (CVAD) left ventricular assist device (LVAD) implantation. A comprehensive literature search of PubMed, Cochrane Library, and ClinicalTrials.gov was conducted up to April 2017. A total of 183 studies were identified; 13 studies met inclusion criteria. The review revealed a trend toward a lower rate of transfusion, and shorter time for cardiopulmonary bypass, as well as a lower 30-day mortality rate for MVAD. This review indicates that there are possible benefits of minimally invasive LVAD implantation, even though the state of literature is poor.