Increased shear stress conferred upon the circulation by continuous-flow pumps is associated with hemocompatibility-related adverse events, principally bleeding within the gastrointestinal system, and linked to the degradation of high-molecular-weight multimers (HMWMs) of von Willebrand factor (vWF). We evaluated the structure and functional characteristics of vWF HMWMs in patients with the fully magnetically levitated centrifugal-flow HeartMate 3 (HM3) and the continuous axial-flow HeartMate II (HMII) pump. Findings were correlated with bleeding events. In a prospective, multicenter, comparative cohort study, 60 patients from the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 Continued Access Protocol (NCT02892955) with an HM3 pump were compared with 30 randomly selected HMII patients from the PREVENtion of HeartMate II Pump Thrombosis study (NCT02158403) biobank. The primary end point was the difference in the normalized vWF HMWM ratio (ratio of the HMWMs to the intermediate- and low-molecular-weight multimers, normalized to pooled plasma from healthy volunteers) between the HM3 and the HMII pump at 90 days after implantation. Assay tests for vWF activity, vWF antigen, vWF activity to antigen ratio, coagulation factor VIII activity, and ADAMTS13 activity were measured by using standard protocols. Differences in these markers were compared in the context of clinical characteristics and correlated with adjudicated bleeding events within the HM3 group. Of 51 and 29 evaluable patients in the HM3 and HMII arms, respectively, those implanted with the HM3 pump exhibited greater preservation of the vWF HMWM ratio than those with the HMII pump at 90 days after implantation (54.1% vs 42.4%, p < 0.0001). Laboratory values for all vWF assays (antigen, activity, and coagulation factor VIII activity) remained within the normal functional range with no significant differences observed between the pumps at 90 days after implantation. At baseline, there was a decrease in the structural integrity of vWF HMWMs that correlated with increasing heart failure severity as measured by the Interagency Registry for Mechanically Assisted Circulatory Support profile. Multivariable modeling identified the HM3 pump as the only independent variable that determined post-implantation preservation of the structural integrity of vWF HMWMs. This prospective, multicenter comparative analysis study demonstrates that the fully magnetically levitated centrifugal-flow HM3 left ventricular assist device is associated with greater preservation of the structure of vWF HMWMs than the HMII mechanical bearing axial-flow pump.
1 October 2011 in Journal of Thrombosis and Haemostasis
Platelet transmission electron microscopy (PTEM) is considered the gold standard test for assessing distinct ultrastructural abnormalities in inherited platelet disorders (IPDs). Nevertheless, PTEM remains mainly a research tool due to the lack of standardized procedures, a validated dense granule (DG) count reference range, and standardized image interpretation criteria. The aim of this study was to standardize and validate PTEM as a clinical laboratory test. Based on previously established methods, we optimized and standardized preanalytical, analytical, and postanalytical procedures for both whole mount (WM) and thin section (TS) PTEM. Mean number of DG/platelet (plt), percentage of plts without DG, platelet count (PC), mean platelet volume (MPV), immature platelet fraction (IPF), and plt light transmission aggregometry analyses were measured on blood samples from 113 healthy donors. Quantile regression was used to estimate the reference range for DG/plt, and linear regression was used to assess the association of DG/plt with other plt measurements. All PTEM procedures were standardized using commercially available materials and reagents. DG interpretation criteria were established based on previous publications and expert consensus, and resulted in improved operator agreement. Mean DG/plt was stable for 2 days after blood sample collection. The median within patient coefficient of variation for mean DG/plt was 22.2%; the mean DG/plt reference range (mid-95th %) was 1.2–4.0. Mean DG/plt was associated with IPF (p = .01, R2 = 0.06) but not age, sex, PC, MPV, or plt maximum aggregation or primary slope of aggregation (p > .17, R2 < 0.02). Baseline ultrastructural features were established for TS-PTEM. PTEM was validated using samples from patients with previously established diagnoses of IPDs. Standardization and validation of PTEM procedures and interpretation, and establishment of the normal mean DG/plt reference range and PTEM baseline ultrastructural features, will facilitate implementation of PTEM as a valid clinical laboratory test for evaluating ultrastructural abnormalities in IPDs.
Objectives: VEXAS syndrome is an adult-onset autoinflammatory disease caused by a somatic pathogenic mutation in the UBA1 (ubiquitin-like modifier activating enzyme 1) gene. Patients present with rheumatologic manifestations and cytopenias and may have an increased predisposition to myelodysplastic syndrome (MDS) and plasma cell neoplasms. Prior studies have reported on the peripheral blood and bone marrow findings in patients with VEXAS syndrome. Due to the protean clinical presentation and lack of specificity of morphologic features (eg, vacuoles in early erythroid and granulocytic precursors), an optimal screening methodology to identify these patients in a timely fashion is desirable. Methods: To further evaluate and describe the salient diagnostic morphologic features in VEXAS syndrome, we carried out a comprehensive study of the largest single-institution cohort to date. Diagnostic and follow-up bone marrow biopsy specimens from 52 male patients with molecularly identified VEXAS syndrome underwent central review. Results: Cytopenias were common in all cases, primarily macrocytic anemia, monocytopenia, and thrombocytopenia. Bone marrow aspirate and biopsy were often hypercellular, with an increased myeloid/erythroid ratio, granulocytic hyperplasia with left shift, erythroid left shift, and megakaryocyte hyperplasia, which exhibited a range of striking morphologic findings. Distinctly vacuolated myeloid and erythroid precursors were seen in more than 95% of cases. Conclusions: Our data reveal potential novel diagnostic features, such as a high incidence of monocytopenia and distinct patterns of atypical megakaryopoiesis, that appear different from dysmegakaryopoiesis typically associated with MDS. In our experience, those findings are suggestive of VEXAS, in the appropriate clinical context.