Reinhard Veltrup

Reinhard Veltrup


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2023 in Journal of Speech, Language, and Hearing Research
Verified
Journal Article
Closed access
RVReinhard Veltrup
Reinhard Veltrup
SKStefan Kniesburges
Stefan Kniesburges
MSMarion Semmler
Marion Semmler
Objective: An experiment with controllable boundaries was designed to assess the influence of the recording angle and distance on two-dimensional (2D) imaging in laryngoscopy and resulting 2D parameter calculation derived from the glottal area waveform (GAW). Method: Two high-speed camera setups were used to synchronously record an oscillating synthetic vocal fold (VF) model, simulating a high-speed videoendoscopy. One camera recorded at variable lateral recording angles and a reference camera in superior perspective. This was performed at different physiological recording distances and for two oscillation modes (with/without contacting VFs). The GAW was derived from the segmented glottis, and two parameters each for the categories of symmetry, periodicity, and closure were calculated, as well as two derivative measures. The percentage difference between the variable and reference camera value pairs was calculated, and the angle and height dependencies were quantified using linear regression. Results: The visual perception of a laryngoscopy was found to be influenced by the lateral recording angle, which may lead to misinterpretation of VF symmetry among inexperienced observers. The strongest influence of recording angle was observed for symmetry parameters, the strongest being the Amplitude Symmetry Index with up to 2.6%/° ( p < .05). A dependence on the recording distance was only found for the Maximum Area Declination Rate. Conclusions: The recording angle in 2D laryngoscopy should be carefully considered during visual inspection of the VF dynamics. Most of the investigated objective parameters were unaffected by the examined perspective distortion. However, especially left–right symmetry measures should only be used under controlled boundary conditions to avoid misdiagnosis and misinterpretation. Supplemental Material: https://doi.org/10.23641/asha.23961183

16 December 2022 in Journal of Voice
Verified
Journal Article
Open access
RLRaphael Lamprecht
Raphael Lamprecht
FSFlorian Scheible
Florian Scheible
RVReinhard Veltrup
Reinhard Veltrup
CSCasey Schaan
Casey Schaan
MSMarion Semmler
Marion Semmler
ASAlexander Sutor
Alexander Sutor
The elastic properties of the vocal folds have great influence on the primary sound and thus on the entire subsequent phonation process. Muscle contractions in the larynx can alter the elastic properties of the vocal fold tissue. Quasi-static ultrasound elastography is a non-destructive examination method that can be applied to ex-vivo vocal folds. In this work, porcine vocal folds were passively elongated and adducted and the changes of the elastic properties due to that manipulations were measured. Manipulations were performed by applying force to sewn-in sutures. Elongation was achieved by a suture attached to the thyroid cartilage, which was pulled forward by defined weights. Adduction was effected by two sutures exerting torque on the arytenoid cartilage. A series of ten specimens was examined and evaluated using a quasi-static elastography algorithm. In addition, the surface stretch was measured optically using tattooed reference points. This study showed that the expected stiffening of the tissue during the manipulations can be measured using quasi-static ultrasound elastography. The measured effect of elongation and adduction, both of which result in stretching of the tissue, is stiffening. However, the relative change of specific manipulations is not the same for the same load on different larynges, but is rather related to stretch caused and other uninvestigated factors. The passive elongation and adduction of vocal folds stiffen the tissue of the vocal folds and can be measured using ultrasound elastography.

31 March 2023 in Journal of Voice
Verified
Journal Article
Open access
FSFlorian Scheible
Florian Scheible
RLRaphael Lamprecht
Raphael Lamprecht
CSCasey Schaan
Casey Schaan
RVReinhard Veltrup
Reinhard Veltrup
JHJann-Ole Henningson
Jann-Ole Henningson
ASAlexander Sutor
Alexander Sutor
The vibration of the vocal folds produces the primary sound for the human speech. The vibration depends mainly on the pressure, airflow of the lungs, and the material properties of the vocal folds. In order to change them, muscles in the larynx stretch the vocal folds. This interplay is rarely investigated, but can give insight in the complex process of speech production. Most material properties studies are damaging the tissue; therefore, a nondestructive one is desired. An ex vivo phonation experiment combined with the dynamic Pipette Aspiration Technique is used to investigate 10 porcine larynges, under manipulations of different adduction and elongation levels. For each manipulation, the near surface material properties of the vocal folds are measured as well as different phonation parameters like the subglottal pressure, glottal resistance, frequency, and stiffness. Thereby, a high-speed camera was used to record the vocal fold movement. On most of the measured parameters, the manipulations do show an effect. Both manipulations lead to a higher phonation frequency and an increase of the stiffness of the tissue. Comparing both manipulations, the elongation results in higher elasticity values than the adduction. Different measurement parameters have been compared with each other and correlations could be found. Where the strongest correlation are found among the elasticity values of different frequencies. But it can also be seen that the elasticity values correlate with phonation parameters. It was possible to produce a data set of 560 measurements in total. To our knowledge, this is the first time Pipette Aspiration Technique was combined with ex vivo phonation measurements for combined measurements. The amount of measurement data made it possible to carry out statistic investigations. The effect of the manipulations on material properties as well as on phonation parameters could be measured and different correlations could be found. The results lead to the hypothesis that the stretch does not have a huge effect on the material properties of the lamina propria, but more on the underlying muscle.

28 September 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
RVReinhard Veltrup
Reinhard Veltrup
SASusanne Angerer
Susanne Angerer
EGElena Gessner
Elena Gessner
FMFriederike Matheis
Friederike Matheis
ESEmily Sümmerer
Emily Sümmerer
MSMarion Semmler
Marion Semmler
The primary acoustic signal of the voice is generated by the complex oscillation of the vocal folds (VFs), whereby physicians can barely examine the medial VF surface due to its anatomical inaccessibility. In this study, we investigated possibilities to infer medial surface dynamics by analyzing correlations in the oscillatory behavior of the superior and medial VF surfaces of four human hemilarynges, each in 24 different combinations of flow rate, VF adduction, and elongation. The two surfaces were recorded synchronously during sustained phonation using two high-speed camera setups and were subsequently 3D-reconstructed. The 3D surface parameters of mean and maximum velocities and displacements and general phonation parameters were calculated. The VF oscillations were also analyzed using empirical eigenfunctions (EEFs) and mucosal wave propagation, calculated from medial surface trajectories. Strong linear correlations were found between the 3D parameters of the superior and medial VF surfaces, ranging from 0.8 to 0.95. The linear regressions showed similar values for the maximum velocities at all hemilarynges (0.69–0.9), indicating the most promising parameter for predicting the medial surface. Since excessive VF velocities are suspected to cause phono-trauma and VF polyps, this parameter could provide added value to laryngeal diagnostics in the future.

29 August 2024 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
RVReinhard Veltrup
Reinhard Veltrup
SASusanne Angerer
Susanne Angerer
EGElena Gessner
Elena Gessner
FMFriederike Matheis
Friederike Matheis
ESEmily Sümmerer
Emily Sümmerer
MSMarion Semmler
Marion Semmler
Objective: This study investigates relationships between the oscillation behavior of the medial and superior vocal fold (VF) surfaces during sustained phonation in a human cadaver hemilarynx. Methods: An experimental test stand synchronously captured the medial and superior VF surfaces of a human ex vivo hemilarynx during sustained phonation using two high-speed camera setups in 24 experimental settings. The 3D coordinates of the medial VF surface were reconstructed by triangulation of sewn-in marker points, while laser-based reconstruction was used for the superior VF surface. Correlation analysis and linear regression were used to quantify the connections of the mean and maximal vertical and lateral VF displacements and the VF velocities. Additionally, stepwise linear regression was used to analyze the impact of the measurement variables mean flow rate, adduction and elongation. Results: Strong linear relationships between all of the tested corresponding parameter pairs of the superior and medial VF surfaces were found (p<.001). Mean and maximum vertical displacements of the medial surface were both approximately 50% of the superior surface. The mean lateral displacements for the medial surface were 12% below the superior surface but 12% higher for the maximum values. The mean and maximum VF velocities were 32% and 36% lower for the medial surface. Conclusion: The suggested multi-modal test stand allows efficient, comprehensive analysis of human hemilarynges and provides promising information about the interaction of the different VF areas and opens up the systematic analysis of multiple hemilarynges. Significance: In future, our results could integrate into ENT diagnostics using 3D laryngoscopy where the hidden medial VF surface dynamics may be predicted from the observable superior surface.

30 June 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
RVReinhard Veltrup
Reinhard Veltrup
SKStefan Kniesburges
Stefan Kniesburges
Michael DöllingerMichael Döllinger
Michael Döllinger
SFSebastian Falk
Sebastian Falk
SMSarina Müller
Sarina Müller
Understanding the risk of infection by routine medical examination is important for the protection of the medical personnel. In this study we investigated respiratory particles emitted by patients during routine otolaryngologic procedures and assessed the risks for the performing physician. We developed two experimental setups to measure aerosol and droplet emission during rigid/flexible laryngoscopy, rhinoscopy, pharyngoscopy, otoscopy, sonography and patient interview for subjects with and without masks. A high-speed-camera setup was used to detect ballistic droplets (approx. > 100 µm) and an aerosol-particle-sizer was used to detect aerosol particles in the range of 0.3 µm to 10 µm. Aerosol particle counts were highly increased for coughing and slightly increased for heavy breathing in subjects without masks. The highest aerosol particle counts occurred during rigid laryngoscopy. During laryngoscopy and rhinoscopy, the examiner was exposed to increased particle emission due to close proximity to the patient’s face and provoked events such as coughing. However, even during sonography or otoscopy without a mask, aerosol particles were expelled close to the examiner. The physician’s exposure to respiratory particles can be reduced by deliberate choice of examination technique depending on medical indication and the use of appropriate equipment for the examiners and the patients (e.g., FFP2 masks for both).