Rita de Cássia Silva Luz

Prof. Dr. Rita de Cássia Silva Luz


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2006 in Talanta
Verified
Journal Article
Closed access
WSWilney J.R. Santos
Wilney J.R. Santos
ASAline L. Sousa
Aline L. Sousa
RLRita de Cássia Silva Luz
Rita de Cássia Silva Luz
FDFlávio S. Damos
Flávio S. Damos
LKLauro T. Kubota
Lauro T. Kubota
STSônia M.C.N. Tanaka
Sônia M.C.N. Tanaka


13 February 2018 in Biosensors
Verified
Journal Article
Open access
PDF file
NRNúbia Fernanda Marinho Rodrigues
Núbia Fernanda Marinho Rodrigues
SNSakae Yotsumoto Neto
Sakae Yotsumoto Neto
RLRita de Cássia Silva Luz
Rita de Cássia Silva Luz
FDFlávio S. Damos
Flávio S. Damos
HYHideko Yamanaka
Hideko Yamanaka
A renewable, disposable, low cost, and sensitive sensor for the detection of organophosphorus pesticides was constructed by immobilizing the acetylcholinesterase enzyme (AChE), via glutaraldehyde, on magnetic iron nanoparticles (Fe3O4) previously synthesized and functionalized with chitosan (CS). The sensor was denoted AChE/CS/Fe3O4. The magnetic nanoparticles were characterized by Fourier transform infrared spectroscopy and transmission electron microscopy. Acetylthiocholine (ATCh) was incubated with AChE/CS/Fe3O4 and attached to a screen-printed electrode using a magnet. The oxidation of thiocholine (from ATCh hydrolysis) was monitored at an applied potential of +0.5 V vs. Ag/AgCl(KClsat) in 0.1 mol L−1 phosphate buffer solution (pH 7.5) as the supporting electrolyte. A mixture of the pesticide malathion and ATCh was investigated using the same procedure, and the results were compared and expressed as inhibition percentages. For determination of malathion, the proposed sensor presented a linear response in the range from 0.5 to 20 nmol L−1 (R = 0.9942). The limits of detection (LOD) and quantification (LOQ) were 0.3 and 0.8 nmol L−1, respectively. Real samples were also investigated, with recovery values of 96.0% and 108.3% obtained for tomato and pond water samples, respectively. The proposed sensor is a feasible option for malathion detection, offering a linear response, good sensitivity, and a low detection limit.

1 April 2006 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
RLRita de Cássia Silva Luz
Rita de Cássia Silva Luz
FDFlávio S. Damos
Flávio S. Damos
ATAuro Atsushi Tanaka
Auro Atsushi Tanaka
LKLauro Tatsuo Kubota
Lauro Tatsuo Kubota

1 August 2013 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
DSDênio E.P. Souto
Dênio E.P. Souto
JSJussara V. Silva
Jussara V. Silva
HMHelen R. Martins
Helen R. Martins
ARAlexandre B. Reis
Alexandre B. Reis
RLRita de Cássia Silva Luz
Rita de Cássia Silva Luz
FDFlávio S. Damos
Flávio S. Damos

1 May 2008 in Electrochimica Acta
Verified
Journal Article
Closed access
CMCamila Marchetti Maroneze
Camila Marchetti Maroneze
LALeliz T. Arenas
Leliz T. Arenas
RLRita de Cássia Silva Luz
Rita de Cássia Silva Luz
EBEdilson Valmir Benvenutti
Edilson Valmir Benvenutti
RLRichard Landers
Richard Landers
YGYoshitaka Gushikem
Yoshitaka Gushikem