Axel Saalbach

Dr. Axel Saalbach

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2020 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
KSK. Sommer
K. Sommer
ASAxel Saalbach
Axel Saalbach
TBT. Brosch
T. Brosch
CHC. Hall
C. Hall
NCN.M. Cross
N.M. Cross
JAJ.B. Andre
J.B. Andre
BACKGROUND AND PURPOSE: Motion artifacts are a frequent source of image degradation in the clinical application of MR imaging (MRI). Here we implement and validate an MRI motion-artifact correction method using a multiscale fully convolutional neural network. MATERIALS AND METHODS: The network was trained to identify motion artifacts in axial T2-weighted spin-echo images of the brain. Using an extensive data augmentation scheme and a motion artifact simulation pipeline, we created a synthetic training dataset of 93,600 images based on only 16 artifact-free clinical MRI cases. A blinded reader study using a unique test dataset of 28 additional clinical MRI cases with real patient motion was conducted to evaluate the performance of the network. RESULTS: Application of the network resulted in notably improved image quality without the loss of morphologic information. For synthetic test data, the average reduction in mean squared error was 41.84%. The blinded reader study on the real-world test data resulted in significant reduction in mean artifact scores across all cases (P < .03). CONCLUSIONS: Retrospective correction of motion artifacts using a multiscale fully convolutional network is promising and may mitigate the substantial motion-related problems in the clinical MRI workflow.

11 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JZJoceline Ziegler
Joceline Ziegler
BPBjarne Pfitzner
Bjarne Pfitzner
HSHeinrich Schulz
Heinrich Schulz
ASAxel Saalbach
Axel Saalbach
Bert ArnrichBert Arnrich
Bert Arnrich
Privacy regulations and the physical distribution of heterogeneous data are often primary concerns for the development of deep learning models in a medical context. This paper evaluates the feasibility of differentially private federated learning for chest X-ray classification as a defense against data privacy attacks. To the best of our knowledge, we are the first to directly compare the impact of differentially private training on two different neural network architectures, DenseNet121 and ResNet50. Extending the federated learning environments previously analyzed in terms of privacy, we simulated a heterogeneous and imbalanced federated setting by distributing images from the public CheXpert and Mendeley chest X-ray datasets unevenly among 36 clients. Both non-private baseline models achieved an area under the receiver operating characteristic curve (AUC) of 0.94 on the binary classification task of detecting the presence of a medical finding. We demonstrate that both model architectures are vulnerable to privacy violation by applying image reconstruction attacks to local model updates from individual clients. The attack was particularly successful during later training stages. To mitigate the risk of a privacy breach, we integrated Rényi differential privacy with a Gaussian noise mechanism into local model training. We evaluate model performance and attack vulnerability for privacy budgets ε∈{1,3,6,10}. The DenseNet121 achieved the best utility-privacy trade-off with an AUC of 0.94 for ε=6. Model performance deteriorated slightly for individual clients compared to the non-private baseline. The ResNet50 only reached an AUC of 0.76 in the same privacy setting. Its performance was inferior to that of the DenseNet121 for all considered privacy constraints, suggesting that the DenseNet121 architecture is more robust to differentially private training.

19 March 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
MMMalte Michel Multusch
Malte Michel Multusch
LHLasse Hansen
Lasse Hansen
MHMattias P. Heinrich
Mattias P. Heinrich
LBLennart Berkel
Lennart Berkel
ASAxel Saalbach
Axel Saalbach
MSMalte Maria Sieren
Malte Maria Sieren
Background/Objectives: In the burgeoning field of medical imaging and Artificial Intelligence (AI), high-quality annotations for training AI-models are crucial. However, there are still only a few large datasets, as segmentation is time-consuming, experts have limited time. This study investigates how the experience of radiologists affects the quality of annotations. Methods: We randomly collected 53 anonymized chest radiographs. Fifteen readers with varying levels of expertise annotated the anatomical structures of different complexity, pneumonic opacities and central venous catheters (CVC) as examples of pathologies and foreign material. The readers were divided into three groups of five. The groups consisted of medical students (MS), junior professionals (JP) with less than five years of working experience and senior professionals (SP) with more than five years of experience. Each annotation was compared to a gold standard consisting of a consensus annotation of three senior board-certified radiologists. We calculated the Dice coefficient (DSC) and Hausdorff distance (HD) to evaluate annotation quality. Inter- and intrareader variability and time dependencies were investigated using Intraclass Correlation Coefficient (ICC) and Ordinary Least Squares (OLS). Results: Senior professionals generally showed better performance, while medical students had higher variability in their annotations. Significant differences were noted, especially for complex structures (DSC Pneumonic Opacities as mean [standard deviation]: MS: 0.516 [0.246]; SP: 0.631 [0.211]). However, it should be noted that overall deviation and intraclass variance was higher for these structures even for seniors, highlighting the inherent limitations of conventional radiography. Experience showed a positive relationship with annotation quality for VCS and lung but was not a significant factor for other structures. Conclusions: Experience level significantly impacts annotation quality. Senior radiologists provided higher-quality annotations for complex structures, while less experienced readers could still annotate simpler structures with satisfying accuracy. We suggest a mixed-expertise approach, enabling the highly experienced to utilize their knowledge most effectively. With the increase in numbers of examinations, radiology will rely on AI support tools in the future. Therefore, economizing the process of data acquisition and AI-training; for example, by integrating less experienced radiologists, will help to meet the coming challenges.

1 January 2012
Verified
Book Chapter
Open access
PDF file
DSDirk Schäfer
Dirk Schäfer
CMCarsten Meyer
Carsten Meyer
RBRoland Bullens
Roland Bullens
ASAxel Saalbach
Axel Saalbach
PEPeter Eshuis
Peter Eshuis
Angiographic projections of the left atrium (LA) and the pulmonary veins (PV) acquired with a rotational C-arm system are used for 3D image reconstruction and subsequent automatic segmentation of the LA and PV to be used as roadmap in fluoroscopy guided LA ablation procedures. Acquisition of projections at high oblique angulations may be problematic due to increased collision danger of the detector with the right shoulder of the patient. We investigate the accuracy of image reconstruction and model based roadmap segmentation using limited angle C-arm tomography. The reduction of the angular range from 200°to 150°leads only to a moderate increase of the segmentation error from 1.5 mm to 2.0 mm if matched conditions are used in the segmentation, i.e. the model based segmentation is trained on images reconstructed with the same angular range as the test images. The minor decrease in accuracy may be outweighed by clinical workflow improvement, gained when large C-arm angulations can be avoided.

1 January 2011
Verified
Book Chapter
Closed access
PDF file
ASAxel Saalbach
Axel Saalbach
IWIrina Wächter-Stehle
Irina Wächter-Stehle
RKReinhard Kneser
Reinhard Kneser
SMSabine Mollus
Sabine Mollus
JPJochen Peters
Jochen Peters
JWJürgen Weese
Jürgen Weese