Seul-gi Lee

Dr. Seul-gi Lee

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2022 in Polymers
Verified
Journal Article
Open access
PDF file
SLSeunghun Lee
Seunghun Lee
SLSeul-gi Lee
Seul-gi Lee
JLJunseo Lee
Junseo Lee
BMByungchol Ma
Byungchol Ma
Combinations of multiple inorganic fillers have emerged as viable synergistic agents for boosting the flame retardancy of intumescent flame retardant (IFR) polymer materials. However, few studies on the effect of multiple inorganic fillers on the flame retardant behavior of rigid polyurethane (RPU) foam have been carried out. In this paper, a flame retardant combination of aluminum hydroxide (ATH) and traditional flame retardants ammonium polyphosphate (APP), pentaerythritol (PER), melamine cyanurate (MC), calcium carbonate (CC), and expandable graphite (EG) was incorporated into RPU foam to investigate the synergistic effects of the combination of multiple IFR materials on the thermal stability and fire resistance of RPU foam. Scanning electron microscopy (SEM) and thermogravimetric analysis (TGA) revealed that 8 parts per hundred polyols by weight (php) filler concentrations were compatible with RPU foam and yielded an increased amount of char residue compared to the rest of the RPU samples. The flame retardancy of multiple fillers on intumescent flame retardant RPU foam was also investigated using cone calorimeter (CCTs) and limiting oxygen index (LOI) tests, which showed that RPU/IFR1 (APP/PER/MC/EG/CC/ATH) had the best flame retardant performance, with a low peak heat release rate (PHRR) of 82.12 kW/m2, total heat release rate (THR) of 15.15 MJ/m2, and high LOI value of 36%. Furthermore, char residue analysis revealed that the use of multiple fillers contributed to the generation of more intact and homogeneous char after combustion, which led to reduced decomposition of the RPU foam and hindered heat transfer between the gas and condensed phases.

25 January 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SLSeul-gi Lee
Seul-gi Lee
EKEun Hee Kim
Eun Hee Kim
BMByungchol Ma
Byungchol Ma
Chemical industrial complexes are extensive, complex structures with large-scale chemical facilities where large quantities of various chemical substances are handled. Detection equipment must be installed in high locations to monitor these industrial complexes and detect chemical accidents from a distance. In previous studies, individual monitoring equipment was temporarily installed on the ground, on a rooftop, or on a vehicle to detect chemical accidents from a distance. In this study, however, the industrial complex chemical accident monitoring system was developed by combining different technologies and was installed on a tower. For the Yeosu National Industrial Complex (which functioned as a test bed), 70m-high steel towers were built. Additionally, an infrared system for remote chemical detection (SIGIS-2, Bruker) and a long-range video surveillance system (TORUSS-LR2000, Globalsystems) were installed at the top of steel towers to monitor the entire industrial complex. The target substances to be monitored in real time by the infrared system for remote chemical detection were selected, and the monitoring sections were classified to enable each piece of equipment to distinguish the scanned areas. To improve the accuracy of the detection results, the information about the actual handled substances and respective facilities of the sites in the industrial complex was inserted into the database of the system and then connected to the sections. During the three-month test operation, various chemical substances (including 1,3-butadiene, methanol, methylamine, ethyl acetate, ammonia, and vinyl chloride) were detected at each section in 20,034 cases, and the detection results were consistent with the inserted actual information. The accumulated detection data shows that the detection frequency of a specific chemical substance was high in each section. This can be used as a basis for modifying the threshold of the anomaly detection model, thereby improving the accuracy of the system. Therefore, this system can detect and evaluate the leakage of chemical substances and the occurrence of fires or smoke through large-scale scans 24 h per day. Furthermore, it can be used for the early detection of and effective responses to chemical accidents in industrial complexes.

4 January 2022 in Chemengineering
Verified
Journal Article
Open access
PDF file
GJGa Young Jung
Ga Young Jung
SLSeul-gi Lee
Seul-gi Lee
JLJunseo Lee
Junseo Lee
BMByungchol Ma
Byungchol Ma
There have been studies recently on bubble-column scrubbers with low cost and high efficiency for the absorption and treatment of hazardous gases in the event of a chemical spill. Bubble columns are vulnerable to freezing at temperatures below zero because the absorbents generally do not circulate. To address this issue, this study focused on the applicability, absorbed amount, and performance of brine as an absorbent. Under three different temperatures, i.e., −5 °C, −8 °C and −10 °C we examined brine (NaCl, CaCl2, and MgCl2) by varying the concentration required at each temperature. Following the experiments, CaCl2 brine was determined as the optimal brine for its absorption performance and affordability. Based on the experimental results, the absorption performance for ammonia, ethylene oxide, and methylamine, which are hazardous and water-soluble gases among accident preparedness substances (APS), was tested by using ASEPN PLUS. Our results suggested although the efficiency dropped by about 5% to 25% when brine was used as an absorbent, it can be used at the low temperatures because the gas solubility increased with decreasing temperature. Therefore, if brine, as an alternative, is used at temperatures about 15 °C, it can operate efficiently and stably without deterioration in the absorption performance. Given our experimental results and design data on the absorbed amount and absorbent replacement period for major hazardous gases are utilized to prevent bubble columns from freezing, it can be commercially used for small and medium-sized enterprises because it can help reduce installation and operation costs.