Baogang Zhang

Prof. Baogang Zhang


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
MLMing Liu
Ming Liu
BZBaogang Zhang
Baogang Zhang
TLTong Luo
Tong Luo
YLYue Liu
Yue Liu
Boris A. PortnovBoris A. Portnov
Boris A. Portnov
QLQingyuan Liu
Qingyuan Liu
The perceived quality of street lighting influences pedestrians’ perceptions of safety and visual comfort, as well as outdoors activities at night. This study explores the association between street lighting attributes, such as illuminance and wavelength, and pedestrians’ feeling of safety (FoS) and perceived lighting quality (PLQ) in eight residential districts in Dalian, China. To achieve this goal, we combine remote sensing technology with ground investigation. The ground research includes physical measurements of lighting attributes, such as intensity, color temperature, and glare, as well as survey evaluations of pedestrians’ perceptions of safety and visual comfort. We also analyze the influence of several environmental factors, such as traffic volumes and vegetation, while accounting for personal characteristics of the observers, such as gender and age. Findings from the remote sensing reveal that Dalian’s residential districts differ substantially by their nighttime light emissions, with high concentration of strong red band (i.e., long wavelength) emissions occurring in Zhongshan and Jinzhou, and strong blue band (i.e., short wavelength) emissions found in central Zhongshan. Results from the ground surveys further indicate that a satisfactory level of FoS reaches at the illumination levels of 5–17 lx, and that people feel safer if nighttime light is warm and uniform. From a multiple regression analysis, it is also found that illuminance and uniformity are the main factors affecting PLQ under conditions of low or high illuminance, while glare and color temperature play a more significant role under high illuminance. In addition, a satisfactory level of PLQ is found at illuminance levels of 25–35 lx and light color temperature of 4000 K–5500 K.

14 July 2022 in Buildings
Verified
Journal Article
Open access
PDF file
BZBaogang Zhang
Baogang Zhang
XCXianglu Cai
Xianglu Cai
MLMing Liu
Ming Liu
The weather in the high latitudes of China is cold in winter. The pollution caused by the burning of biomass fuels used in rural individual heating is a great threat to human health. This study finds that the amounts of CO2, CO, PM2.5, and PM10 in the bedroom exceed the standard and the temperature does not meet the standard based on indoor air measurements in rural residential buildings in Liaoning Province in winter. In this study, a mechanical ventilation method which uses flue gas to preheat fresh air is proposed, for the purpose of simultaneously improving the indoor air quality and the thermal environment of rural houses. The flue gas–fresh air heat exchange (FGFAHE) experiment shows that biomass combustion flue gas can increase the outdoor air temperature by 23.7 °C on average. The ventilation experiment shows that the method of mechanical ventilation combined with external window penetration can increase the dilution rate of indoor CO by more than 1 times. The simulation results of six different ventilation schemes show that the ventilation mode of the diagonal opposite side upper air supply and lower exhaust air (DOUSLE) has the best effect on indoor CO prevention and control, and the mode of median air supply is the most beneficial to the indoor thermal environment.

16 June 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
BZBaogang Zhang
Baogang Zhang
YLYiwei Li
Yiwei Li
MLMing Liu
Ming Liu
YLYuchuan Liu
Yuchuan Liu
TLTong Luo
Tong Luo
WJWeili Jiao
Weili Jiao
With the continuously growing city size and the increasingly complex and changeable light environment in the city, remote sensing and ground-measured technologies have certain limitations in the research of urban night light environment. The ground-measured data are accurate but low in efficiency and small in scale, while the night-light remote sensing data have the characteristics of high accuracy and large coverage. In this paper, high-resolution night-light remote sensing data and high-accuracy ground-measured data were used to establish an urban ground light environment inversion method with the advantages of remote sensing and ground-measured data in a “space-ground collaboration” approach. A ground database is constructed in GIS based on 26,000 ground measurement data of 4 blocks, 3 spatial perspectives, and 3 light environment parameters. Based on the comparison of the numerical relationship between the measured data of each light environment parameter and each window, the horizontal window is selected as the target window for the ground night light environment inversion research. The urban night light environment inversion method based on the correlation between telemetry and ground- measurement is used to construct and compare the correlation between Luojia night light radiance data and 9 sets of measured data of different ground windows and different light environment parameters. The illuminance measured data of horizontal window and Luojia radiance data, both of which are highly correlated, are selected for regression analysis. The mathematical inversion model of ground illuminance is constructed based on the cubic polynomial model with the lowest RMSE among the six regression models. The inversion result not only has photometric calibration, but also is superior to the original data in terms of population data relevance and accuracy.

9 July 2024 in Buildings
Verified
Journal Article
Open access
PDF file
BZBaogang Zhang
Baogang Zhang
YWYongjuan Wang
Yongjuan Wang
MLMing Liu
Ming Liu
ZZZhongbing Zhang
Zhongbing Zhang
In this study, the heating capacity of a new prefabricated assembled hot water radiant modular heating system made from a recycled waste building masonry structure is investigated through experimental and numerical simulation methods. The heating capacity of the system in different working conditions (a water supply temperature of 48 °C, 51 °C, 56 °C, and 61 °C; a flow rate of 0.49 m3/h, 0.35 m3/h, and 0.21 m3/h) is analyzed and verified. A three-dimensional steady-state heat transfer numerical model of the floor heat transfer of the module is established, and the accuracy of the model is verified through the measured results to investigate the heating capacity of this system under different water supply temperatures, flow rates and coil spacings. The results show that the new prefabricated hot water radiant module heating system has a 0.9 °C higher air temperature and 2.1 °C higher average floor surface temperature than the traditional wet floor radiant heating system under the same experimental conditions, and the response time is 44% shorter. The water supply temperature can significantly change the heating capacity of the system, while the water supply flow rate has little effect on the system. The established three-dimensional steady-state numerical model can be in good agreement with the measured results. This study can provide an experimental and theoretical basis for the design and application of such systems.

24 May 2025 in Buildings
Verified
Journal Article
Open access
PDF file
BZBaogang Zhang
Baogang Zhang
WWWeitao Wang
Weitao Wang
MLMing Liu
Ming Liu
MLMingxuan Liu
Mingxuan Liu
This study addresses the freeze-up problem in HVAC system heat exchangers of industrial buildings in severely cold regions by proposing a collaborative anti-freeze control strategy based on multi-objective optimization. Taking a diesel engine laboratory as the research case, key freezing-inducing factors were identified through system performance analysis and fault diagnosis. An innovative interlocked anti-freeze control system was developed by integrating electric heating with dynamic regulation of bypass air volume. Utilizing gray relational analysis, the optimal interlock control scheme was selected from four alternatives based on a comprehensive performance evaluation. Multi-objective optimization through the NSGA-II algorithm was performed on parameters including the set temperature, water flow rate, and fresh air volume, achieving coordinated optimization of energy consumption (11.4% reduction compared to pre-optimization) and thermal comfort. TRNSYS-based simulation verification demonstrated that the system maintains a 94.71% freeze protection time assurance rate under extreme operating conditions, effectively resolving the reliability deficiencies of traditional solutions in severely cold environments. This research provides a novel method for industrial building HVAC system anti-freeze design that harmonizes energy efficiency and comfort performance.

28 October 2026 in Buildings
Verified
Journal Article
Open access
PDF file
BZBaogang Zhang
Baogang Zhang
JSJiabo Song
Jiabo Song
XPXinchen Pan
Xinchen Pan
WWWeitao Wang
Weitao Wang
Aiming to address the universal challenge that conventional phase-change material (PCM) walls for cold-climate rural buildings have low overall thermal resistance, causing rapid nocturnal heat loss and poor latent-heat utilization, this work develops composite specimens combining aerogel insulation coating and microencapsulated-PCM mortar for rural residences in Northern China. Experimental measurements and COMSOL Multiphysics®6.3 (COMSOL)-calibrated numerical simulations are adopted to investigate the coupled heat-transfer mechanism and multi-dimensional trade-offs among thermal regulation performance, mechanical properties and PCM cyclic-utilization efficiency. The results reveal that rising PCM dosage reduces the density and thermal conductivity of mortar; the specimen with a 30% PCM sand-replacement ratio plus 5 mm aerogel coating reaches a thermal conductivity of 0.116 W/(m·K). Owing to synergistic effects, aerogel mitigates external thermal disturbances to optimize PCM melting–solidification cycles while PCM buffers indoor temperature swings, delivering improved temperature-attenuation performance. Parametric analysis demonstrates that 30% PCM replacement and 23.0 °C phase-change temperature form a multi-objective equilibrium balancing thermal regulation, mechanical durability and PCM utilization, instead of a thermal-only optimum. Since these parameters are obtained under Dalian meteorological conditions and cannot be generalized, the proposed material–climate matching principle offers analytical references for low-carbon retrofitting of rural building envelopes in other high-latitude cold regions.