The influence of the bending radius on the sensitivity of the graphene quantum dots (GQDs)-coated probe is experimentally investigated for a U-shaped probe. The fiber is bent into a U shape using the optic fiber flame heating method, and the optic fiber is enclosed in a glass tube to increase the stability of the probe. The surface of the U-shaped optical fiber was coated with electrospun fibers formed via electrospinning. Polymer materials doped with GQDs are applied to U-shaped optical fiber as humidity sensors. Graphene quantum dot nanofibers on the U-shaped optical fiber sensor to form a network structure of graphene quantum dots U-shape fiber sensor (GQDUS). The polymer network structure absorbs water molecules, which in turn affects the bending radius of the optical fiber, and changes the optical fiber spectrum. Graphene quantum dots provide optical enhancement benefits, which in turn increase the sensitivity of fiber optic sensors. The spectra monitoring system consists of an optical spectrum analyzer (OSA) and an amplified spontaneous emission (ASE). This system can be used to detect humidity changes between 20% RH and 80% RH in the chamber. Our results indicate promising applications for quantum dots probe sensors from electrospun nanofibers increasing sensitive environmental monitoring. As such, it could be of substantial value in optical sensors detection.
This study describes the fabrication of an electrospun, U-shaped optical fiber sensor for temperature measurements. The sensor is based on single mode fibers and was fabricated into a U-shaped optical fiber sensor through flame heating. This study applied electrospinning to coat PVA, a polymer, onto the sensor layer to reduce its sensitivity to humidity. The sensor is used to measure temperature variations ranging from 30 °C to 100 °C. The objectives of this study were to analyze the sensitivity variation of the sensor with different sensor layer thicknesses resulting from different electrospinning durations, as well as to simulate the wavelength signals generated at different electrospinning durations using COMSOL. The results revealed that the maximum wavelength sensitivity, transmission loss sensitivity, and linearity of the sensor were 25 dBm/°C, 70 pm/°C, and 0.956, respectively. Longer electrospinning durations resulted in thicker sensor layers and higher sensor sensitivity, that wavelength sensitivity of the sensor increased by 42%.
The study focuses on the thermal and temperature sensitivity behavior of an optical fiber sensor device. In this article, a titanium nitride (TiN)-coated fiber Bragg grating (FBG) sensor fabricated using an ion beam sputtering system was investigated. The reflection spectra of the FBG sensor were tested using R-soft optical software to simulate the refractive index sensitivity. In these experiments, the temperature sensitivity of the TiN FBG was measured at temperatures ranging from 100 to 500 °C using an optical spectrum analyzer (OSA). The results showed that the temperature sensitivity of the proposed TiN FBG sensor reached 12.8 pm/°C for the temperature range of 100 to 300 °C and 20.8 pm/°C for the temperature range of 300 to 500 °C. Additionally, we found that the produced oxidation at temperatures of 400-500 °C caused a crack, with the crack becoming more and more obvious at higher and higher temperatures.
In this study, we applied a double-sided inductively coupled plasma (ICP) process to nanostructure long-period fiber grating (LPFG) in order to fabricate a double-notched LPFG (DNLPFG) sensor with a double-sided surface corrugated periodic grating. Using the sol-gel method, we also added thymol blue and ZnO to form a gas sensing layer, thus producing a DNLPFG CO2 gas sensor. The resulting sensor is the first double-sided etching sensor used to measure CO2. The experimental results showed that as the CO2 concentration increased, the transmission loss increased, and that the smaller the fiber diameter, the greater the sensitivity and the greater the change in transmission loss. When the diameter of the fiber was 32 μm (and the period was 570 μm) and the perfusion rate of CO2 gas was 15%, the maximum loss variation of up to 3.881 dB was achieved, while the sensitivity was 0.2146 dB/% and the linearity was 0.992. These results demonstrate that the DNLPG CO2 gas sensor is highly sensitive.