Lihua Wang

Dr. Lihua Wang

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 October 2022 in Journal of International Medical Research
Verified
Journal Article
Open access
LWLihua Wang
Lihua Wang
LJLan Jia
Lan Jia
AJAili Jiang
Aili Jiang
Despite the considerable efforts made to increase the prevalence of autogenous fistula in patients on hemodialysis, tunneled cuffed catheters are still an important access modality and used in a high percentage of the hemodialysis population. However, because of the conundrum posed by tunneled cuffed catheters, patients can develop a multitude of complications, including thrombosis, infections, formation of a fibrin sheath, and central vein stenosis, resulting in increased morbidity and mortality as well as placing a heavy burden on the healthcare system. However, with an increasing number of studies now focusing on how to manage these catheter-related complications, there has been less translational research on the pathology of these complications. This review of the most recent literature provides an update on the pathological aspects of catheter-related complications, highlighting what we need to know and what is yet to be discovered. The future research strategies and innovations needed to prevent these complications are also addressed.

Verified
Journal Article
Open access
PDF file
Xianjiang LiXianjiang Li
Xianjiang Li
CLChen Li
Chen Li
XBXueqing Bi
Xueqing Bi
FWFang Wei
Fang Wei
JMJia Meng
Jia Meng
AJAili Jiang
Aili Jiang
Inflammation plays a significant role in the occurrence and development of acute kidney injury (AKI). Evidence regarding the prognostic effect of the systemic immune-inflammation index (SII) in critically ill patients with AKI is scarce. The aim of this study was to assess the association between SII and all-cause mortality in these patients. Detailed clinical data were extracted from the Medical Information Mart for Intensive Care Database (MIMIC)-IV. The primary outcome was set as the in-hospital mortality. A total of 10,764 AKI patients were enrolled in this study. The restricted cubic splines analyses showed a J-shaped curve between SII and the risk of in-hospital and ICU mortality. After adjusting for relevant confounders, multivariate Cox regression analysis showed that both lower and higher SII levels were associated with an elevated risk of in-hospital all-cause mortality. A similar trend was observed for ICU mortality. In summary, we found that the SII was associated in a J-shaped pattern with all-cause mortality among critically ill patients with AKI. SII appears to be have potential applications in the clinical setting as a novel and easily accessible biomarker for predicting the prognosis of AKI patients.

19 July 2021 in Iranian Journal of Kidney Diseases
Verified
Journal Article
Closed access
LWLihua Wang
Lihua Wang
LCLin Cheng
Lin Cheng
HCHaiyan Chen
Haiyan Chen
FWFang Wei
Fang Wei
AJAili Jiang
Aili Jiang
Angiotensin receptor neprilysin inhibitor (ARNI) has been recommended by major guidelines as the leading therapy for heart failure with reduced ejection fraction (HFrEF). But little is known about its safety and effectiveness among maintenance hemodialysis patients with HFrEF in real-word practice. An observational study was conducted among maintenance hemodialysis patients who received ARNI at our dialysis center. Enrollment commenced on June 1, 2018; and follow-up was completed on May 31, 2019. A total of 110 patients included in the study (age: 54.2 ± 14.8 y, 59% males). After 12 months of treatment, the average ARNI daily dose increased from 135 mg to 308 mg. The mean NT-pro- BNP concentration at baseline was 14455 pg/mL and 6435 pg/ mL after 12 months of treatment (P < .001). The left ventricular ejection fraction improved (35.1 vs. 49.8%, P < .001) over the 12 months, while left ventricular end-diastolic diameter, left ventricular mass index, left ventricular end-systolic diameter, and left atrial diameter also changed significantly (167.8 vs. 154.9 g/m, P < .001; 52.2 vs. 51.5 mm, P < .05; 35.9 vs. 36.9 mm, P < .001; 42.2 vs. 40.3 mm, P < .001). Furthermore, we found the quality of life and the NYHA symptom severity class improved significantly (P < .001). Kaplan-Meier analysis indicated that higher dose of ARNI and less vintage of HD were associated with best survival. In our study, ARNI appeared to be safe, relieved heart failure symptoms, and improved the scores of KCCQ physical and social activities in hemodialysis patients in real-world practice.


23 September 2021 in The Journal of Vascular Access
Verified
Journal Article
Closed access
PDF file
DCDiego Celdran-Bonafonte
Diego Celdran-Bonafonte
LWLihua Wang
Lihua Wang
AJAous Jarrouj
Aous Jarrouj
BCBegona Campos-Naciff
Begona Campos-Naciff
JJJaroslav Janda
Jaroslav Janda
PRPrabir Roy-Chaudhury
Prabir Roy-Chaudhury
Background: Although tunneled dialysis catheters (TDC) are far from ideal, they still represent the main form of vascular access for most patients beginning dialysis. Catheters are easy to place and allow patients instant access to dialysis, but regardless of these benefits, catheters are associated with a high incidence of significant complications like bloodstream infections, central venous stenosis, thrombosis, and dysfunction. In the present study, we aim to describe and characterize a swine model of catheter dysfunction and bloodstream infection, that recreates the clinical scenario, to help to serve as a platform to develop therapeutic innovations for this important clinical problem. Methods: Six Yorkshire cross pigs were used in this study. Non-coated commercial catheters were implanted in the external jugular recreating the main features of common clinical practice. Catheters were aseptically accessed twice a week for a mock dialysis procedure (flushing in and out) to assess for and identify catheter dysfunction. Animals were monitored daily for infections; once detected, blood samples were collected for bacterial culture and antibiograms. Study animals were euthanized when nonresponsive to treatment. Tissue samples were collected in a standardized fashion for macroscopic inspection and histological analysis. Results: The data analysis revealed an early onset of infection with a median time to infection of 9 days, 40% of the isolates were polymicrobial, and the average time to euthanasia was 20.16 ± 7.3 days. Median time to catheter dysfunction onset was 6 days post-implantation. Postmortem dissection revealed external fibrin sheath and internal thrombosis as the main causes of catheter dysfunction. There was also evidence of central venous stenosis with positive cells for αSMA, CD68, Ki67, Smoothelin, and Vimentin within the venous neointima. Conclusions: The described model represents a reliable and reproducible large animal model of catheter dysfunction and bloodstream infection, which recreates all the main complications of TDC’s and so could be used as a validated large animal model to develop new therapies for TDC related infection, thrombosis/dysfunction and central venous stenosis.

27 September 2016 in The Journal of Vascular Access
Verified
Journal Article
Open access
LWLihua Wang
Lihua Wang
FWFang Wei
Fang Wei
HCHaiyan Chen
Haiyan Chen
GSGuijiang Sun
Guijiang Sun
HYHaibo Yu
Haibo Yu
AJAili Jiang
Aili Jiang
Purpose: For patients who rely on a tunneled cuffed catheter, replacement or catheter removal is typically necessary. We recently performed a modified de novo insertion technique for catheter replacement in our practice. As the technique has not yet been studied comprehensively, we performed a retrospective study to evaluate the safety and efficacy of de novo placed catheter without delay for catheter replacement in elderly hemodialysis patients. Methods: A retrospective review of 164 elderly patients was conducted during a period of three years. There were 84 patients in study group, as well as 80 patients in a control group, who had catheter replacement by guidewire exchange technique. Clinical follow-up data was collected. Results: All catheters were placed successfully. The mean survival time per catheter was 641 catheter days (study group) and 485 catheter days (control group). The primary patency rates of 30 days were 97.7% (study group) and 90% (control group), respectively, with statistically significant difference (p = 0.04). The incidence of catheter infection was not statistically significantly different in both groups (p = 0.586), but the case of catheter dysfunction was significantly lower in study group compared to control group (p = 0.003). Conclusions: The de novo placed catheter without delay technique for catheter replacement near the pre-existing venotomy site is safe, and boasts similar infection rates with lower dysfunction rates compared to tunneled catheter insertion by guidewire exchange technique.