Noam Ben-Eliezer

Dr. Noam Ben-Eliezer

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2014 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
NBNoam Ben-Eliezer
Noam Ben-Eliezer
DSDaniel K. Sodickson
Daniel K. Sodickson
KBKai Tobias Block
Kai Tobias Block
Purpose: Quantitative T2‐relaxation‐based contrast has the potential to provide valuable clinical information. Practical T2‐mapping, however, is impaired either by prohibitively long acquisition times or by contamination of fast multiecho protocols by stimulated and indirect echoes. This work presents a novel postprocessing approach aiming to overcome the common penalties associated with multiecho protocols, and enabling rapid and accurate mapping of T2 relaxation values.Methods: Bloch simulations are used to estimate the actual echo‐modulation curve (EMC) in a multi–spin‐echo experiment. Simulations are repeated for a range of T2 values and transmit field scales, yielding a database of simulated EMCs, which is then used to identify the T2 value whose EMC most closely matches the experimentally measured data at each voxel.Results: T2 maps of both phantom and in vivo scans were successfully reconstructed, closely matching maps produced from single spin‐echo data. Results were consistent over the physiological range of T2 values and across different experimental settings.Conclusion: The proposed technique allows accurate T2 mapping in clinically feasible scan times, free of user‐ and scanner‐dependent variations, while providing a comprehensive framework that can be extended to model other parameters (e.g., T1, B1+, B0, diffusion) and support arbitrary acquisition schemes. Magn Reson Med 73:809–817, 2015. © 2014 Wiley Periodicals, Inc.

23 April 2010 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
NBNoam Ben-Eliezer
Noam Ben-Eliezer
MIMichal Irani
Michal Irani
LFLucio Frydman
Lucio Frydman

1 January 2010 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
NBNoam Ben-Eliezer
Noam Ben-Eliezer
YSYoav Shrot
Yoav Shrot
LFLucio Frydman
Lucio Frydman

17 April 2015 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
NBNoam Ben-Eliezer
Noam Ben-Eliezer
DSDaniel K. Sodickson
Daniel K. Sodickson
TSTimothy Shepherd
Timothy Shepherd
GWGraham C. Wiggins
Graham C. Wiggins
KBKai Tobias Block
Kai Tobias Block

28 February 2011 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
NBNoam Ben-Eliezer
Noam Ben-Eliezer
LFLucio Frydman
Lucio Frydman

1 January 2017 in NeuroImage: Clinical
Verified
Journal Article
Open access
TSTimothy M. Shepherd
Timothy M. Shepherd
IKIvan I. Kirov
Ivan I. Kirov
ECErik Charlson
Erik Charlson
MBMary Bruno
Mary Bruno
JBJames Babb
James Babb
NBNoam Ben-Eliezer
Noam Ben-Eliezer
Quantitative T2 mapping may provide an objective biomarker for occult nervous tissue pathology in relapsing-remitting multiple sclerosis (RRMS). We applied a novel echo modulation curve (EMC) algorithm to identify T2 changes in normal-appearing brain regions of subjects with RRMS (N = 27) compared to age-matched controls (N = 38). The EMC algorithm uses Bloch simulations to model T2 decay curves in multi-spin-echo MRI sequences, independent of scanner, and scan-settings. T2 values were extracted from normal-appearing white and gray matter brain regions using both expert manual regions-of-interest and user-independent FreeSurfer segmentation. Compared to conventional exponential T2 modeling, EMC fitting provided more accurate estimations of T2 with less variance across scans, MRI systems, and healthy individuals. Thalamic T2 was increased 8.5% in RRMS subjects (p < 0.001) and could be used to discriminate RRMS from healthy controls well (AUC = 0.913). Manual segmentation detected both statistically significant increases (corpus callosum & temporal stem) and decreases (posterior limb internal capsule) in T2 associated with RRMS diagnosis (all p < 0.05). In healthy controls, we also observed statistically significant T2 differences for different white and gray matter structures. The EMC algorithm precisely characterizes T2 values, and is able to detect subtle T2 changes in normal-appearing brain regions of RRMS patients. These presumably capture both axon and myelin changes from inflammation and neurodegeneration. Further, T2 variations between different brain regions of healthy controls may correlate with distinct nervous tissue environments that differ from one another at a mesoscopic length-scale.