1 January 2016 in Journal of Electrical and Computer Engineering
Verified
Journal Article
Open access
PDF file
MAM. Sabbaghpur Arani
M. Sabbaghpur Arani
MHMaryam Akhavan Hejazi
Maryam Akhavan Hejazi
The rapid growth of the solar industry over the past several years has expanded the significance of photovoltaic (PV) systems. Fault analysis in solar photovoltaic (PV) arrays is a fundamental task to increase reliability, efficiency, and safety in PV systems and, if not detected, may not only reduce power generation and accelerated system aging but also threaten the availability of the whole system. Due to the current-limiting nature and nonlinear output characteristics of PV arrays, faults in PV arrays may not be detected. In this paper, all possible faults that happen in the PV system have been classified and six common faults (shading condition, open-circuit fault, degradation fault, line-to-line fault, bypass diode fault, and bridging fault) have been implemented in 7.5 KW PV farm. Based on the simulation results, both normal operational curves and fault curves have been compared.


10 February 2022 in Journal of Power Sources
Verified
Journal Article
Closed access
MAMehrdad Aslani
Mehrdad Aslani
AIAmir Imanloozadeh
Amir Imanloozadeh
HHHamed Hashemi-Dezaki
Hamed Hashemi-Dezaki
MHMaryam Akhavan Hejazi
Maryam Akhavan Hejazi
MNMohammad Nazififard
Mohammad Nazififard
AKAbbas Ketabi
Abbas Ketabi

5 December 2019 in Electronics
Verified
Journal Article
Open access
PDF file
JFJamal Faraji
Jamal Faraji
MBMasoud Babaei
Masoud Babaei
Navid BayatiNavid Bayati
Navid Bayati
MHMaryam Akhavan Hejazi
Maryam Akhavan Hejazi
Extreme weather events lead to electrical network failures, damages, and long-lasting blackouts. Therefore, enhancement of the resiliency of electrical systems during emergency situations is essential. By using the concept of standby redundancy, this paper proposes two different energy systems for increasing load resiliency during a random blackout. The main contribution of this paper is the techno-economic and environmental comparison of two different resilient energy systems. The first energy system utilizes a typical traditional generator (TG) as a standby component for providing electricity during the blackouts and the second energy system is a grid-connected microgrid consisting of photovoltaic (PV) and battery energy storage (BES) as a standby component. Sensitivity analyses are conducted to investigate the survivability of both energy systems during the blackouts. The objective function minimizes total net present cost (NPC) and cost of energy (COE) by considering the defined constraints of the system for increasing the resiliency. Simulations are performed by HOMER, and results show that for having almost the same resilience enhancement in both systems, the second system, which is a grid-connected microgrid, indicates lower NPC and COE compared to the first system. More comparison details are shown in this paper to highlight the effectiveness and weakness of each resilient energy system.

1 December 2016 in Energy
Verified
Journal Article
Closed access
ARA. Rahiminejad
A. Rahiminejad
Behrooz VahidiBehrooz Vahidi
Behrooz Vahidi
MHMaryam Akhavan Hejazi
Maryam Akhavan Hejazi
SSS. Shahrooyan
S. Shahrooyan

30 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MGMohsen Ghorat
Mohsen Ghorat
Gevork B. GharehpetianGevork B. Gharehpetian
Gevork B. Gharehpetian
HLHamid Latifi
Hamid Latifi
MHMaryam Akhavan Hejazi
Maryam Akhavan Hejazi
MBMehdi Bagheri
Mehdi Bagheri
This paper presented a new sensor to detect and localize partial discharge (PD) in power transformers based on a fiber Bragg grating (FBG). The fundamental characteristics of the proposed sensor, as a PD detector, were temperature compensation and direction independence. The proposed high-resolution PD detector operated based on the FBG wavelength shift. It is necessary to evaluate the physical parameters of the sensor to achieve the best results. Therefore, in this paper, the detected signal strength was investigated for different angles and temperatures. A Teflon hollow mandrel and two FBGs attached to the inner and outer surfaces of the hollow mandrel were chosen as the inner transformer PD detector. The changes in the sensor output were less than 0.4 mV and 0.5 mV for direction variations and a temperature variation of 14 °C (degrees Celsius), respectively. Consequently, the proposed sensor could be successfully employed for the detection of a transformer PD signal.