Problems of rapid degradation and poor biocompatibility (endothelialization and hemocompatibility) limit magnesium (Mg) alloy’s further applications in vascular stents. To solve these problems, a novel composite coating was designed on Mg alloy via a two-step method. First, a Mg alloy sample was immersed in hydrofluoric acid. Then, a poly-l-lactic acid (PLLA) coating was made by ultrasonic atomization spraying with 5 and 10 layers (referred to as PLLA(5)-HF-Mg and PLLA(10)-HF-Mg). Characterizations were analyzed from the microstructure, element distribution, and wettability. The degradation behavior was tested with an electrochemical test and immersion test. Endothelialization was investigated using human umbilical vein endothelial cells (HUVECs). Hemocompatibility was examined with a platelet adhesion test. The results showed that the PLLA coating could not only cover the surface, but also could permeate through and cover the holes on the MgF2 layer, mechanically locked with the substrate. Thus, the composite coating had higher corrosion resistance. The PLLA/MgF2 coating, especially on PLLA(10)-HF-Mg, enhanced HUVECs’ viability and growth. While incubated with platelets, the PLLA/MgF2 coating, especially on PLLA(10)-HF-Mg, had the lowest platelet adhesion number and activity. Taken together, the novel PLLA/MgF2 coating controls Mg alloy’s degradation by spraying different layers of PLLA, resulting in better endothelialization and hemocompatibility, providing a promising candidate for cardiovascular stents.
The coronary stent deployment and subsequent service process is a complex geometric/physical nonlinear and fluid–structure coupling system. Analyzing the distribution of stress–strain on the stent is of great significance in studying the deformation and failure behavior. A coupled system dynamics model comprising stenotic coronary artery vessels and L-type Mg alloy stents was established by applying the polynomial hyperelastic constitutive theory. The nonlinear, significant deformation behavior of the stent was systematically studied. The stress–strain distribution of the coupling system during stent deployment was analyzed. The simulation results show that the edges of the supporting body fixed without a bridge are the weakest zone. The stress changes on the inside of the wave of the supporting body are very large, and the residual stress accumulated in this area is the highest. The peak stress of the plaque and the arterial wall was lower than the damage threshold. The velocity of the blood between the wave crest of the supporting body is large and the streamline distribution is concentrated. In addition, the inner surface pressure on the stent is evenly distributed along its axial dimension. The maximum arterial wall shear stress always appears on the inside of the wave crest of the supporting body fixed with a bridge, and, as such, the largest obstacle to the blood flow is in this zone.