Trani Menaka Bandara Konara Konara Mudiyanselage

Mr. Trani Menaka Bandara Konara Konara Mudiyanselage

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Shanuka Kamesh DodampegamaShanuka Kamesh Dodampegama
Shanuka Kamesh Dodampegama
Amith Prasadana MudugamuwaAmith Prasadana Mudugamuwa
Amith Prasadana Mudugamuwa
TMTrani Menaka Bandara Konara Konara Mudiyanselage
Trani Menaka Bandara Konara Konara Mudiyanselage
NPNisal Perera
Nisal Perera
DSDinindu De Silva
Dinindu De Silva
Hiroki TamuraHiroki Tamura
Hiroki Tamura
Nature consists of numerous solutions to overcome challenges in designing artificial systems. Various actuation mechanisms have been implemented in microrobots to mimic the motion of microorganisms. Such bio-inspired designs have contributed immensely to microscale developments. Among the actuation mechanisms, magnetic actuation is widely used in bio-inspired microrobotic systems and related propulsion mechanisms used by microrobots to navigate inside a magnetic field and are presented in this review. In addition, the considered robots are in microscale, and they can swim inside a fluidic environment with a low Reynolds number. In relation to microrobotics, mimicry of bacteria flagella, sperm flagella, cilia, and fish are significant. Due to the fact that these biological matters consist of different propulsion mechanisms, the effect of various parameters was investigated in the last decade and the review presents a summary that enhances understanding of the working principle of propulsion mechanisms. In addition, the effect of different parameters on the various speeds of the existing microrobots was analyzed to identify their trends. So, the swimming speeds of the microrobots show an upward trend with increasing body length, frequency, magnetic flux density, and helix angle. Microfabrication techniques play a significant role in the microscale because the device designs are highly dependent on the availability of the techniques. The presented microrobots were manufactured by 3D/4D photolithography and rapid prototyping techniques. Proper materials enable effective fabrication of microrobots using the mentioned techniques. Therefore, magnetically active material types, matrix materials, biocompatible and biodegradable materials are presented in this study. Utilizing biocompatible and biodegradable materials avoids adverse effects to the organs that could occur otherwise. In addition, magnetic field generation is significant for the propulsion of such microrobots. We conclude the review with an overview of the biomimicry of microrobots and magnetically actuated robot propulsion.

2 February 2025 in Applied Mechanics
Verified
Journal Article
Open access
PDF file
Md Mainuddin SagarMd Mainuddin Sagar
Md Mainuddin Sagar
TMTrani Menaka Bandara Konara Konara Mudiyanselage
Trani Menaka Bandara Konara Konara Mudiyanselage
NPNate Picard
Nate Picard
Kihan ParkKihan Park
Kihan Park
Researchers are currently conducting several studies in the field of navigation systems and sensors. Even in the past, there was a lot of research regarding the field of velocity sensors for unmanned underwater vehicles (UUVs). UUVs have various services and significance in the military, scientific research, and many commercial applications due to their autonomy mechanism. So, it’s very crucial for the proper maintenance of the navigation system. Reliable navigation of unmanned underwater vehicles depends on the quality of their state determination. There are so many navigation systems available, like position determination, depth information, etc. Among them, velocity determination is now one of the most important navigational criteria for UUVs. The key source of navigational aids for different deep-sea research projects is water currents. These days, many different sensors are available to monitor the UUV’s velocity. In recent times, there have been five primary types of sensors utilized for UUV velocity forecasts. These include Doppler Velocity Logger sensors, paddlewheel sensors, optical sensors, electromagnetic sensors, and ultrasonic sensors. The most popular sensing sensor for estimating velocity at the moment is the Doppler Velocity Logger (DVL) sensor. DVL sensor is the most fully developed sensor for UUVs in recent years. In this work, we offer an overview of the field of navigation systems and sensors (especially velocity) developed for UUVs with respect to their use with tidal current sensing in the UUV setting, including their history, evolution, current research initiatives, and anticipated future.

16 November 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
TMTrani Menaka Bandara Konara Konara Mudiyanselage
Trani Menaka Bandara Konara Konara Mudiyanselage
Amith Prasadana MudugamuwaAmith Prasadana Mudugamuwa
Amith Prasadana Mudugamuwa
Shanuka Kamesh DodampegamaShanuka Kamesh Dodampegama
Shanuka Kamesh Dodampegama
URUditha Roshan
Uditha Roshan
RARanjith Amarasinghe
Ranjith Amarasinghe
Dzung DaoDzung Dao
Dzung Dao
Multiple robots are used in robotic applications to achieve tasks that are impossible to perform as individual robotic modules. At the microscale/nanoscale, controlling multiple robots is difficult due to the limitations of fabrication technologies and the availability of on-board controllers. This highlights the requirement of different approaches compared to macro systems for a group of microrobotic systems. Current microrobotic systems have the capability to form different configurations, either as a collectively actuated swarm or a selectively actuated group of agents. Magnetic, acoustic, electric, optical, and hybrid methods are reviewed under collective formation methods, and surface anchoring, heterogeneous design, and non-uniform control input are significant in the selective formation of microrobotic systems. In addition, actuation principles play an important role in designing microrobotic systems with multiple microrobots, and the various control systems are also reviewed because they affect the development of such systems at the microscale. Reconfigurability, self-adaptable motion, and enhanced imaging due to the aggregation of modules have shown potential applications specifically in the biomedical sector. This review presents the current state of shape formation using microrobots with regard to forming techniques, actuation principles, and control systems. Finally, the future developments of these systems are presented.

13 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Amith Prasadana MudugamuwaAmith Prasadana Mudugamuwa
Amith Prasadana Mudugamuwa
SHSamith Hettiarachchi
Samith Hettiarachchi
Gehan MelroyGehan Melroy
Gehan Melroy
Shanuka Kamesh DodampegamaShanuka Kamesh Dodampegama
Shanuka Kamesh Dodampegama
TMTrani Menaka Bandara Konara Konara Mudiyanselage
Trani Menaka Bandara Konara Konara Mudiyanselage
PWPeihong Wang
Peihong Wang
This paper discusses an active droplet generation system, and the presented droplet generator successfully performs droplet generation using two fluid phases: continuous phase fluid and dispersed phase fluid. The performance of an active droplet generation system is analysed based on the droplet morphology using vision sensing and digital image processing. The proposed system in the study includes a droplet generator, camera module with image pre-processing and identification algorithm, and controller and control algorithm with a workstation computer. The overall system is able to control, sense, and analyse the generation of droplets. The main controller consists of a microcontroller, motor controller, voltage regulator, and power supply. Among the morphological features of droplets, the diameter is extracted from the images to observe the system performance. The MATLAB-based image processing algorithm consists of image acquisition, image enhancement, droplet identification, feature extraction, and analysis. RGB band filtering, thresholding, and opening are used in image pre-processing. After the image enhancement, droplet identification is performed by tracing the boundary of the droplets. The average droplet diameter varied from ~3.05 mm to ~4.04 mm in the experiments, and the average droplet diameter decrement presented a relationship of a second-order polynomial with the droplet generation time.

5 May 2025 in Actuators
Verified
Journal Article
Open access
PDF file
TMTrani Menaka Bandara Konara Konara Mudiyanselage
Trani Menaka Bandara Konara Konara Mudiyanselage
MPMishal Pokharel
Mishal Pokharel
Md Mainuddin SagarMd Mainuddin Sagar
Md Mainuddin Sagar
YKYeongjin Kim
Yeongjin Kim
Kihan ParkKihan Park
Kihan Park
Light-actuated microbots have been studied as a viable tool for interacting with micro/nano environments. Considering their applicability to a wide range of biomedical applications, novel designs, fabrication techniques, and control methodologies are being developed. Especially, micro/nanoscale three-dimensional fabrication techniques have opened many possibilities for developing microbots with complex geometries using resins as materials. Here, we developed microbots that can be actuated with tightly focused laser beams to be used in targeted drug delivery, cell poking, and cell characterization studies. These microbots were fabricated in batches using two-photon polymerization (TPP). Each microbot utilizes a deposited metal layer inside its body to manipulate convective microfluidic flows. Additionally, micro-sized end effectors allow them to make measurable physical contact with biological objects. Their expected performance was evaluated using numerical simulations with the use of multiphysics software. Furthermore, laser-induced loading and unloading of micro-sized cargo show their capability for in vitro applications.

1 August 2025 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
MPMishal Pokharel
Mishal Pokharel
ANAbid Neron
Abid Neron
Amit Kumar DeyAmit Kumar Dey
Amit Kumar Dey
ASAishwariya Raksha Siddharthan
Aishwariya Raksha Siddharthan
TMTrani Menaka Bandara Konara Konara Mudiyanselage
Trani Menaka Bandara Konara Konara Mudiyanselage
Kihan ParkKihan Park
Kihan Park
Background: A precise drug delivery system enables the optimization of treatments with minimal side effects if it can deliver medication only when activated by a specific light source. This study presents a controlled drug delivery system based on poly(lactic-co-glycolic acid) (PLGA) microparticles (MPs) designed for the sustained release of vancomycin hydrochloride. Methods: The MPs were co-loaded with indocyanine green (ICG), a near-infrared (NIR) responsive agent, and fabricated via the double emulsion method.They were characterized for stability, surface modification, biocompatibility, and antibacterial efficacy. Results: Dynamic light scattering and zeta potential analyses confirmed significant increases in particle size and surface charge reversal following chitosan coating. Scanning electron microscopy revealed uniform morphology in uncoated MPs (1–10 μm) and irregular surfaces post-coating. Stability tests demonstrated drug retention for up to 180 days. Among formulations, PVI1 exhibited the highest yield (76.67 ± 1.3%) and encapsulation efficiency (56.2 ± 1.95%). NIR irradiation (808 nm) enhanced drug release kinetics, with formulation PVI4 achieving over 48.9% release, resulting in improved antibacterial activity. Chitosan-coated MPs (e.g., PVI4-C) effectively suppressed drug release without NIR light for up to 8 h, with cumulative release reaching only 10.89%. Without NIR light, bacterial colonies exceeded 1000 CFU; NIR-triggered release reduced them below 120 CFU. Drug release data fitted best with the zero-order and Korsmeyer–Peppas models, suggesting a combination of diffusion-controlled and constant-rate release behavior. Conclusions: These results demonstrate the promise of chitosan-coated NIR-responsive PLGA MPs for precise, on-demand antibiotic delivery and improved antibacterial performance.