Laure Morimont

Mrs. Laure Morimont

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2021 in Frontiers in Endocrinology
Verified
Journal Article
Open access
LMLaure Morimont
Laure Morimont
HHHélène Haguet
Hélène Haguet
JDJean-Michel Dogné
Jean-Michel Dogné
UGUlysse Gaspard
Ulysse Gaspard
JDJonathan Douxfils
Jonathan Douxfils
Many factors must be considered and discussed with women when initiating a contraceptive method and the risk of venous thromboembolism (VTE) is one of them. In this review, we discuss the numerous strategies that have been implemented to reduce the thrombotic risk associated with combined oral contraceptives (COCs) from their arrival on the market until today. Evidences suggesting that COCs were associated with an increased risk of VTE appeared rapidly after their marketing. Identified as the main contributor of this risk, the dosage of the estrogen, i.e., ethinylestradiol (EE), was significantly reduced. New progestins were also synthetized (e.g., desogestrel or gestodene) but their weak androgenic activity did not permit to counterbalance the effect of EE as did the initial progestins such as levonorgestrel. Numerous studies assessed the impact of estroprogestative combinations on hemostasis and demonstrated that women under COC suffered from resistance towards activated protein C (APC). Subsequently, the European Medicines Agency updated its guidelines on clinical investigation of steroid contraceptives in which they recommended to assess this biological marker. In 2009, estradiol-containing COCs were marketed and the use of this natural form of estrogen was found to exert a weaker effect on the synthesis of hepatic proteins compared to EE. In this year 2021, a novel COC based on a native estrogen, i.e., estetrol, will be introduced on the market. Associated with drospirenone, this preparation demonstrated minor effects on coagulation proteins as compared with other drospirenone-containing COCs. At the present time, the standard of care when starting a contraception, consists of identifying the presence of hereditary thrombophilia solely on the basis of familial history of VTE. This strategy has however been reported as poorly predictive of hereditary thrombophilia. One rationale and affordable perspective which has already been considered in the past could be the implementation of a baseline screening of the prothrombotic state to provide health care professionals with objective data to support the prescription of the more appropriate contraceptive method. While this strategy was judged too expensive due to limited laboratory solutions, the endogenous thrombin potential-based APC resistance assay could now represent an interesting alternative.

14 July 2021 in Viruses
Verified
Journal Article
Open access
PDF file
JFJulien Favresse
Julien Favresse
Gillot ConstantGillot Constant
Gillot Constant
LCLaura Di Chiaro
Laura Di Chiaro
CEChristine Eucher
Christine Eucher
MEMarc Elsen
Marc Elsen
JDJonathan Douxfils
Jonathan Douxfils
The evaluation of the neutralizing capacity of anti-SARS-CoV-2 antibodies is important because they represent real protective immunity. In this study we aimed to measure and compare the neutralizing antibodies (NAbs) in COVID-19 patients and in vaccinated individuals. One-hundred and fifty long-term samples from 75 COVID-19 patients were analyzed with a surrogate virus neutralization test (sVNT) and compared to six different SARS-CoV-2 serology assays. The agreement between the sVNT and pseudovirus VNT (pVNT) results was found to be excellent (i.e., 97.2%). The NAb response was also assessed in 90 individuals who had received the complete dose regimen of BNT162b2. In COVID-19 patients, a stronger response was observed in moderate–severe versus mild patients (p-value = 0.0006). A slow decay in NAbs was noted in samples for up to 300 days after diagnosis, especially in moderate–severe patients (r = −0.35, p-value = 0.03). In the vaccinated population, 83.3% of COVID-19-naive individuals had positive NAbs 14 days after the first dose and all were positive 7 days after the second dose, i.e., at day 28. In previously infected individuals, all were already positive for NAbs at day 14. At each time point, a stronger response was observed for previously infected individuals (p-value < 0.05). The NAb response remained stable for up to 56 days in all participants. Vaccinated participants had significantly higher NAb titers compared to COVID patients. In previously infected vaccine recipients, one dose might be sufficient to generate sufficient neutralizing antibodies.

13 January 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JFJulien Favresse
Julien Favresse
Gillot ConstantGillot Constant
Gillot Constant
MOMaxime Oliveira
Maxime Oliveira
JCJulie Cadrobbi
Julie Cadrobbi
MEMarc Elsen
Marc Elsen
JDJonathan Douxfils
Jonathan Douxfils
(1) Background: The detection of SARS-CoV-2 RNA in nasopharyngeal samples through real-time reverse transcription-polymerase chain reaction (RT-PCR) is considered the standard gold method for the diagnosis of SARS-CoV-2 infection. Antigen detection (AD) tests are more rapid, less laborious, and less expensive alternatives but still require clinical validation. (2) Methods: This study compared the clinical performance of five AD tests, including four rapid AD (RAD) tests (biotical, Panbio, Healgen, and Roche) and one automated AD test (VITROS). For that purpose, 118 (62.8%) symptomatic patients and 70 (37.2%) asymptomatic subjects were tested, and results were compared to RT-PCR. (3) Results: The performance of the RAD tests was modest and allowed us to identify RT-PCR positive patients with higher viral loads. For Ct values ≤25, the sensitivity ranged from 93.1% (95% CI: 83.3–98.1%) to 96.6% (95% CI: 88.1–99.6%), meaning that some samples with high viral loads were missed. Considering the Ct value proposed by the CDC for contagiousness (i.e., Ct values ≤33) sensitivities ranged from 76.2% (95% CI: 65.4–85.1%) to 88.8% (95% CI: 79.7–94.7%) while the specificity ranged from 96.3% (95% CI: 90.8–99.0%) to 99.1% (95% CI: 95.0–100%). The VITROS automated assay showed a 100% (95% CI: 95.5–100%) sensitivity for Ct values ≤33, and had a specificity of 100% (95% CI: 96.6–100%); (4) Conclusions: Compared to RAD tests, the VITROS assay fully aligned with RT-PCR for Ct values up to 33, which might allow a faster, easier and cheaper identification of SARS-CoV-2 contagious patients.

24 August 2019 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Closed access
PDF file
JDJonathan Douxfils
Jonathan Douxfils
LMLaure Morimont
Laure Morimont
ADAnne-Sophie Delvigne
Anne-Sophie Delvigne
PDPhilippe Devel
Philippe Devel
BMBernard Masereel
Bernard Masereel
JDJean-Michel Dogné
Jean-Michel Dogné
Background: Regulatory bodies recommend the use of an assay based on the assessment of the endogenous thrombin potential (ETP) for the investigation of the activated protein C resistance (APCr) in the development of steroid contraceptives in women. However, the assays described in the literature are home-made and not standardized regarding the method, the reagents, the reference plasma and the quality controls. In the absence of any commercially available method, we aimed at validating the ETP-based APCr assay. Methods: The validation was performed according to regulatory standards. The method targets a 90% inhibition of the ETP in healthy donors in the presence of APC compared to the same condition in the absence of APC. As a large-scale production of a pool of plasma from well-selected healthy donors is impossible, algorithms were applied to a commercial reference plasma to correlate with the selected pool. Results: Repeatability and intermediate precision passed the acceptance criteria. The assay demonstrated a curvilinear dose response to protein S and APC concentrations (R2 > 0.99). Analysis of plasma samples from 47 healthy individuals (22 women not taking combined hormonal contraceptives [CHC], and 25 men not Factor V Leiden carriers) confirmed the validity of the test, with a mean inhibition percentage of 90%. Investigations in 15 women taking different contraceptives and in two subjects with Factor V Leiden confirmed the good sensitivity and performance of the assay. Conclusions: This validation provides the pharmaceutical industry, the regulatory bodies and physicians with a reproducible, sensitive and validated gold-standard ETP-based APCr assay.

13 September 2022 in The Journal of Clinical Endocrinology & Metabolism
Verified
Journal Article
Open access
PDF file
LMLaure Morimont
Laure Morimont
MJMaud Jost
Maud Jost
UGUlysse Gaspard
Ulysse Gaspard
JFJean-Michel Foidart
Jean-Michel Foidart
JDJean-Michel Dogné
Jean-Michel Dogné
JDJonathan Douxfils
Jonathan Douxfils
Objective: To compare the impact on thrombin generation of the new combined oral contraceptive containing 15 mg estetrol and 3 mg drospirenone with ethinylestradiol (30 or 20 mcg) associated either with 150 mcg levonorgestrel or with 3 mg drospirenone. Methods: Data were collected from the “E4/DRSP Endocrine Function, Metabolic Control and Hemostasis Study” (NCT02957630). Overall, the per-protocol set population included 24 subjects in the ethinylestradiol/levonorgestrel arm, 28 subjects in the ethinylestradiol/drospirenone arm, and 34 subjects in the estetrol/drospirenone arm. Thrombograms and thrombin generation parameters (lag time, peak, time to peak, endogenous thrombin potential, and mean velocity rate index) were extracted for each subject at baseline and after 6 cycles of treatment. Results: After 6 cycles of treatment, ethinylestradiol-containing products arms show a mean thrombogram outside the upper limit of the reference range, that is the 97.5th percentile of all baseline thrombograms. On the other hand, the mean thrombogram of estetrol/drospirenone is within this reference interval. After 6 cycles of treatment, all thrombin generation parameters are statistically less affected by estetrol/drospirenone than ethinylestradiol-containing products. Conclusions: In conclusion, an association of 15 mg estetrol with 3 mg drospirenone does not have an impact on thrombin generation compared with ethinylestradiol-containing products that, either associated with levonorgestrel or drospirenone, are able to increase the production of procoagulant factors and decrease the production of anticoagulant ones, shifting the patient to a prothrombotic state. Ethinylestradiol-containing products thus generate prothrombotic environments contrary to estetrol which demonstrates a neutral profile on hemostasis.

7 May 2019 in Journal of Thrombosis and Haemostasis
Verified
Journal Article
Open access
PDF file
JDJonathan Douxfils
Jonathan Douxfils
LMLaure Morimont
Laure Morimont
CBCéline Bouvy
Céline Bouvy
MSMarie de Saint‐Hubert
Marie de Saint‐Hubert
BDBérangère Devalet
Bérangère Devalet
FMFrançois Mullier
François Mullier
Background Thrombin generation testing has been used to provide information on the coagulation phenotype of patients. The most used technique is the calibrated automated thrombogram (CAT) but it suffers from a lack of standardization preventing its implementation in routine. The ST Genesia is a new analyzer designed to assess thrombin generation based on the same principle as the CAT. Unlike the CAT system, the ST Genesia is a benchtop fully automated analyzer, able to perform the analyses individually and not by batch, with strict control of variables like temperature and volumes, ensuring, theoretically, a maximal reproducibility. Objectives This study aimed at assessing the performance of the STG®‐DrugScreen application on the ST Genesia analyzer. We also aimed at exploring stability of plasma samples after freezing and defining a reference normal range. Results Results demonstrated the excellent inter‐experiment precision of the ST Genesia and confirmed that the use of a reference plasma helps reducing the inter‐experiments variability. Stability revealed that plasma samples are stable for at least 11 months at ‐70°C or below, except for those containing low molecular weight heparins which have to be tested within 6 months. Freezing had no impact on the majority of thrombin generation parameters except on time‐to‐peak. Conclusions Our results suggest an easy implementation of thrombin generation with the use of ST Genesia in the routine laboratory. This will facilitate the design of multicentric studies and enable the establishment of reliable and evidence‐based thresholds, which may improve the management of patients treated with anticoagulants.