Luis Bracero

Prof. Dr. Luis Bracero

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2025 in Academic Medicine
Verified
Journal Article
Closed access
FJFrank Jackson
Frank Jackson
NKNathan A. Keller
Nathan A. Keller
IKInsaf Kouba
Insaf Kouba
WKWassil Kouba
Wassil Kouba
LBLuis Bracero
Luis Bracero
MBMatthew Blitz
Matthew Blitz
Problem: Clinical vignette–based multiple-choice questions (MCQs) have been used to assess postgraduate medical trainees but require substantial time and effort to develop. Large language models, a type of artificial intelligence (AI), can potentially expedite this task. This report describes prompt engineering techniques used with ChatGPT-4 to generate clinical vignettes and MCQs for obstetrics-gynecology residents and evaluates whether residents and attending physicians can differentiate between human- and AI-generated content. Approach: The authors generated MCQs using a structured prompt engineering approach, incorporating authoritative source documents and an iterative prompt chaining technique, to refine output quality. Fifty human-generated and 50 AI-generated MCQs were randomly arranged into 10 quizzes (10 questions each). The AI-generated MCQs were developed in August 2024 and surveys conducted in September 2024. Obstetrics-gynecology residents and attending physician faculty members at Northwell Health or Donald and Barbara Zucker School of Medicine at Hofstra/Northwell completed an online survey, answering each MCQ and indicating whether they believed it was human or AI written or if they were uncertain. Outcomes: Thirty-three participants (16 residents, 17 attendings) completed the survey (80.5% response rate). Respondents correctly identified MCQ authorship a median (interquartile range [IQR]) of 39.1% (30.0%–50.0%) of the time, indicating difficulty in distinguishing human- and AI-generated questions. The median (IQR) correct answer selection rate was 62.3% (50.0%–75.0%) for human-generated MCQs and 64.4% (50.0%–83.3%) for AI-generated MCQs ( P = .74). The difficulty (0.69 vs 0.66, P = .83) and discriminatory (0.42 vs 0.38, P = .90) indexes showed no significant differences, supporting the feasibility of large language model–generated MCQs in medical education. Next Steps: Future studies should explore the optimal balance between AI-generated content and expert review, identifying strategies to maximize efficiency without compromising accuracy. The authors will develop practice exams and assess their predictive validity by comparing scores with standardized exam results.

1 December 2017 in Reproductive Toxicology
Verified
Journal Article
Closed access
LBLuis Bracero
Luis Bracero
SMStefan Maxwell
Stefan Maxwell
ANAfua Nyanin
Afua Nyanin
DSDara J. Seybold
Dara J. Seybold
AWApril White
April White
MBMike Broce
Mike Broce

4 October 2021 in Journal of Medical Screening
Verified
Journal Article
Closed access
PDF file
DSDara J Seybold
Dara J Seybold
LBLuis Bracero
Luis Bracero
PPPeter Power
Peter Power
ZKZachary A Koenig
Zachary A Koenig
BCByron C Calhoun
Byron C Calhoun
SBStephen Bush
Stephen Bush
The objective was to determine if a screening tool for obstructive sleep apnea could be used to predict adverse perinatal outcomes. This was a prospective observational study of patients receiving prenatal care and universally screened for obstructive sleep apnea with the STOP Questionnaire (four questions related to Snoring, Tiredness during daytime, Observed apnea, and high blood Pressure). Confounding variables were included in a backwards logistic regression model to predict adverse perinatal outcomes. The study population of 442 women had positive STOP screens (64; 14.5%) associated with preterm delivery and neonatal intensive care unit admissions. For preterm delivery, history of preterm delivery was the strongest predictor with odds ratios of 4.2 (95% confidence interval 2.0–8.8; p < 0.001), followed by STOP, odds ratios 2.8 (95% confidence interval 1.4–5.8; p = 0.004) and nulliparity, odds ratios 2.3 (95% confidence interval 1.2–4.4; p = 0.013). A positive STOP was the only significant predictor for neonatal intensive care unit admissions, odds ratios 2.5 (95% confidence interval 1.1–5.7; p = 0.036). STOP screening test performance indicated low sensitivity but high specificity: preterm delivery (28.3%, 87.4%), neonatal intensive care unit admissions (27.3%, 86.6%), low birth weight (25.0%, 86.9%), and preeclampsia (16.7%, 85.6%). As a stand-alone tool, the STOP Questionnaire has limited performance, but could be explored in combination with other factors that might increase sensitivity to predict preterm delivery and neonatal intensive care unit admission.

1 April 2019 in Reproductive Toxicology
Verified
Journal Article
Closed access
SMStefan Maxwell
Stefan Maxwell
STStephanie Thompson
Stephanie Thompson
FZFadi Zakko
Fadi Zakko
LBLuis Bracero
Luis Bracero

26 June 2023 in Medical Ultrasonography
Verified
Journal Article
Closed access
PDF file
IKInsaf Kouba
Insaf Kouba
LBLuis Bracero
Luis Bracero
KMKarmaine Millington
Karmaine Millington
MBMatthew Blitz
Matthew Blitz
The effect of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) on placental tissue is unclear. We present a case of symptomatic first trimester SARS-CoV-2 infection in which longitudinal ultrasound images demonstrated diffuse areas of echogenic foci. Her 39-week delivery, following an elective induction of labor, was uncomplicated, and placental pathol-ogy evaluation noted extensive calcifications. Such findings are sometimes seen in late and post-term pregnancies and those complicated by smoking, hypertensive disorders, diabetes, and viral infections. In this case, no other potential etiology was identified. Thus, we conclude that placental calcifications may be associated with SAR-CoV-2 infection in early pregnancy.

1 July 2004 in Gynecologic and Obstetric Investigation
Verified
Journal Article
Closed access
SHShoshana Haberman
Shoshana Haberman
LBLuis Bracero
Luis Bracero
DBDaniel W. Byrne
Daniel W. Byrne
Objective: To determine the value of Doppler measurements obtained by a new multigate Doppler modality, the spectral Doppler index mapping (SDIM) technique, to predict adverse outcome among pregnant women with normal conventional umbilical artery (UA) Doppler indices. Design: A cross-sectional prospective cohort study. Subjects: 183 women with well-dated singleton pregnancies who underwent prenatal ultrasound examination between 18 and 40 weeks of gestation were included in the study. At the time of the initial Doppler examination, all patients had normal UA and uterine artery Doppler indices, size appropriate for gestational age, no evidence of fetal anomalies or fetal distress. Methods: SDIM data included the distribution curves of the pulsatility indices (PI) as well as the mean of the PI detected in the placenta and in the umbilical cord. The mean PI values were also calculated using conventional spectral Doppler sonography. Logistic regression analysis was used to control for gestational age while assessing various Doppler variables in predicting outcome. Results: Adverse outcomes occurred in 26.6% of the pregnancies. In pregnancies with adverse outcome, the umbilicoplacental PI gradient was significantly lower (0.10 vs. 0.28, p < 0.003), the maximum intraplacental PI value was higher (1.28 vs. 1.16, p = 0.031), and there was a greater proportion with skewed UA distribution curves. Using forward stepwise logistic regression to compare the predictive value of the conventional Doppler ultrasound with SDIM, we found that the most accurate predictors of adverse outcome were the maximum intraplacental PI value (p < 0.028), skewed distributions (p = 0.002) and the gradient between the umbilical and intraplacental PI distributions (p = 0.006). Conclusions: Our results suggest that the SDIM system may enhance the ability of Doppler technology to predict obstetrical outcomes in patients with normal UA Doppler indices.