Luiz A. C. Lopes

Prof. Dr. Luiz A. C. Lopes

Department of Electrical and Computer Engineering, Concordia University, 1515 Ste. Catherine West EV 005-407, Montreal, QC, Canada

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 March 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
MAMohammadhossein Ashourianjozdani
Mohammadhossein Ashourianjozdani
Luiz A. C. LopesLuiz A. C. Lopes
Luiz A. C. Lopes
PPPragasen Pillay
Pragasen Pillay
This paper presents a converter-based permanent magnet synchronous generator (PMSG) emulator as a testbed for designing, analyzing, and testing of the generator's power electronic interface and its control system. The permanent magnet synchronous generator model is formulated in a real-time digital simulator. A voltage type ideal transformer model (ITM) combined with a virtual impedance is presented as an interface algorithm. The design procedure and implementation of the virtual impedance in a simulation platform is discussed. A 6-switch voltage source converter (VSC) is used as a power amplifier to mimic the behavior of the PMSG supplying linear and nonlinear loads. A proportional integral plus resonant (PI+res) controller is proposed as a voltage loop controller for tracking a distorted output voltage reference signal. The accuracy of the proposed emulator is investigated for the fundamental and low order voltage harmonics. Technical challenges of the PMSG emulator are considered, and proper solutions are suggested. The performance of the proposed emulator is compared with an actual PMSG.

1 October 2007
Verified
Conference Paper
Closed access
GDGhulam Dastagir
Ghulam Dastagir
Luiz A. C. LopesLuiz A. C. Lopes
Luiz A. C. Lopes
This paper discusses the regulation of the voltage and frequency of a stand-alone self-excited squirrel-cage induction generator (SEIG) connected to an unregulated prime mover by means of a single voltage source inverter (VSI) connected in shunt with the stator of the generator. A battery bank is used at the dc side of the VSI so that it can deal active and reactive power and affect the frequency and magnitude of the generated voltage. The focus of this paper is on the experimental results obtained for a 4-pole 2 HP SEIG with an unregulated prime- mover with a linear torque versus speed characteristic typical of impulse type hydro turbines. It shows that active and reactive power control yields a better voltage and frequency regulation to load variations than reactive power alone.

1 January 2006
Verified
Conference Paper
Closed access
NDNeil S. D'Souza
Neil S. D'Souza
Luiz A. C. LopesLuiz A. C. Lopes
Luiz A. C. Lopes
XLXuejun Liu
Xuejun Liu
The perturbation and observation (P&O) maximum power point tracking (MPPT) algorithms are very common in PV systems. Implementations of P&O algorithms based on peak current control and on instantaneous sampled values have shown to provide very fast transients and small oscillations around the maximum power point (MPP). However, operation with fixed variation of the reference current results in a tradeoff between speed of response and maximum power yield in the steady state. Variable variation of the reference current can be successfully done with fuzzy logic but results in significant computation burden for common digital signal processors (DSP). Thus the minimum time step is relatively large what reduces the transient response of the scheme. This paper presents an alternative approach based on non-switching zones and compares by simulation the performance and discusses the implementation difficulties of 4 peak-current controlled P&O MPPT algorithms

1 October 2009
Verified
Conference Paper
Closed access
RTReinaldo Tonkoski
Reinaldo Tonkoski
Luiz A. C. LopesLuiz A. C. Lopes
Luiz A. C. Lopes
FRF. Dos Reis
F. Dos Reis
Low and medium power wind energy conversion systems (WECS) are expected to be simple, low cost and reliable. They are usually implemented with fixed pitch wind turbines. In such a case, operation with variable speed for increased capture of wind energy requires a power electronics converter capable of adjusting the shaft speed. This is done by controlling the active power drawn from the generator. Permanent magnet synchronous generators (PMSG) are a good option for low power variable speed WECS since they do not require external excitation nor reactive power to operate. Typically, an ac-dc converter composed of a diode rectifier and a capacitive filter, connected to a voltage source inverter is used as an interface to a grid or to a load. The highly distorted input currents of the diode rectifier with capacitive filters produce additional power losses in the generator that can reduce its lifetime. This paper discusses the use of a single-switch three-phase boost rectifier in the front end of the power electronic interface. It provides means for regulating the shaft speed by duty cycle variation while reducing the generator losses when compared to the standard diode and capacitive filter scheme. Simulation and experimental results show the effectiveness of the proposed scheme for reducing the generator copper and core losses and also the internal temperature.

1 September 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AMAhmad B. Malkawi
Ahmad B. Malkawi
Luiz A. C. LopesLuiz A. C. Lopes
Luiz A. C. Lopes
DC bus voltage signaling (DBS) and droop control are frequently employed in DC nano and microgrids with distributed energy resources (DERs) operating in a decentralized way. This approach is effective in enforcing the desired contributions of power sources and energy storage systems (ESSs) in steady-state conditions. The use of supercapacitors (SCs) along with batteries in a hybrid energy storage system (HESS) can mitigate the impact of high and fast current variations on the losses and lifetime of the battery units. However, by controlling the HESS as a single unit, one forfeits the potential contribution of the SC and its high power capabilities to dynamically improve voltage regulation in a DC nanogrid. This paper discusses an approach where the SC interface is controlled independently from the battery interface, with a small droop factor and a high pass filter (HPF), to produce high and short current pulses and smooth DC bus voltage variations due to sudden power imbalances in the DC nanogrid. Experimental results are presented to show that, unlike in a conventional HESS, the SC unit can be used to improve the dynamic voltage regulation of the DC nanogrid and, indirectly, mitigate the high and fast current variations in the battery.

16 July 2013 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
OMOlivare Dzune Mipoung
Olivare Dzune Mipoung
Luiz A. C. LopesLuiz A. C. Lopes
Luiz A. C. Lopes
PPPragasen Pillay
Pragasen Pillay
Diesel hybrid autonomous power systems (mini-grids) capable of operating with high penetration of wind usually require additional means to mitigate the impact of fluctuating wind energy on stability and power quality. The use of energy storage units and sophisticated wind turbines (WTs) with pitch angle control and/or a power electronics interface are deemed essential. They become costly and not economically attractive for many small remote communities with limited resources. This paper investigates the potential of inexpensive fixed-pitch directly coupled squirrel-cage-induction-generator-based (type 1) WTs for assisting with frequency stability and support in a storage-less diesel hybrid mini-grid. The impact of some parameters of the WT on the magnitude of the slope of its power-versus-frequency (droop) characteristics is examined. The results show that a type-1 WT with an increased droop slope can reduce frequency variations in the mini-grid as well as variations of power and torque in the diesel engine generator set.