Exploring the potential of microfluidic systems, this study presents a groundbreaking approach harnessing energy in microfluidic flows within a purpose‐built microreactor, enabling precise deposition of functional biomaterials. Upon optimizing reactor dimensions and integrating it into a microfluidic system, sequentially flow‐induced deposition of DNA hydrogels and transformation into DNA‐protein hybrid materials with SpyTag/SpyCatcher technology is investigated. However, limited functionalization rates restrict its viability for targeted biocatalytic processes. Therefore, the direct deposition of a phenolic acid decarboxylase is investigated, which is efficiently deposited but shows limited biocatalytic performance due to shear‐induced denaturation. This challenge is overcome by a two‐step immobilization process, resulting in microfluidic bioreactors demonstrating initial high space‐time yields of up to 7000 g L−1 d−1, but whose process stability proves unsatisfactory. However, by exploiting the principle of flow‐induced deposition to immobilize recombinant E. coli cells as functional living materials overexpressing biocatalytically relevant enzymes, bioreactors are produced that show equally high space‐time yields in continuous whole‐cell catalysis which remain constant over periods of up to 10 days. The insights gained offer optimization strategies for advanced functional materials and innovative reactor systems holding promise for applications in fundamental materials science, biosensing, and scalable production of microreactors for biocatalysis and bioremediation.
The working principle of lateral flow assays, such as the widely used COVID-19 rapid tests, is based on the capillary-driven liquid transport of a sample fluid to a test line using porous polymeric membranes as the conductive medium. In order to predict this wicking process by simplified analytical models, it is essential to determine an effective capillary radius for the highly porous and open-pored membranes. In this work, a parametric study is performed with selected simplified structures, representing the complex microstructure of the membrane. For this, a phase-field approach with a special wetting boundary condition to describe the meniscus formation and the corresponding mean surface curvature for each structure setup is used. As a main result, an analytical correlation between geometric structure parameters and an effective capillary radius, based on a correction factor, are obtained. The resulting correlation is verified by applying image analysis methods on reconstructed computer tomography scans of two different porous polymeric membranes and thus determining the geometric structure parameters. Subsequently, a macroscale flow model that includes the correlated effective pore size and geometrical capillary radius is applied, and the results are compared with wicking experiments. Based on the derived correction function, it is shown that the analytical prediction of the wicking process in highly porous polymeric membranes is possible without the fitting of experimental wicking data. Furthermore, it can be seen that the estimated effective pore radius of the two membranes is 8 to 10 times higher than their geometric mean pore radii.
To describe the dynamics of fluid flow in Lateral Flow Assays (LFAs) and to understand the effect of geometry on the propagation speed of the fluid front, a single-phase model is developed. The model can predict wicking time for different geometries. Axisymmetric geometries with changes in their cross sections are studied to understand the wicking behavior. To validate the modeling results, imaging experiments that capture the fluid front are conducted on all geometries. In all cases, convincing agreement between modeling results and experimental data has been observed. Using data-driven information and knowledge about structure–property correlations, it is possible to control wicking processes to establish a desired velocity at a specific position in LFAs. The proposed approach serves as a basis for the creation of a design tool for application-oriented membranes.
Lateral flow assays (LFAs) have caught new attention in recent years due to extensive use in the containment of the COVID-19 pandemic. Especially the protein and fluid interactions with the nitrocellulose membrane structure are yet to be fully investigated, which affect the fluid and protein distribution of the test and control lines differently due to different adsorptive properties of fluids and proteins. Therefore, the relationship between fluid spread and protein distribution, respectively, and structure needs systematic evaluation. Two procedures were developed based on passive adsorption of complementary fluorescent dyes to investigate these phenomena. These procedures enabled three-dimensional visualization of the membrane structure, fluid as well as the protein spreading, respectively. Confocal laser scanning microscopy was applied after depositing picoliter and nanoliter volumes of the printing buffers containing fluorophore-labeled proteins (immunoglobulin G) and Oregon Green™ 488 onto the membrane using a high precision micro dispenser. The resulting data were correlated with the membrane's tortuosity and permeability. Inverse-proportional dependencies for the lateral spread of the fluid and protein adsorption with the structural parameters were observed. Additionally, surfactants [polysorbate 80 (PS80) and sodium dodecylbenzenesulfonate (SDBS), both at 0.1%] were added individually to the buffers, and the spread of the liquids was evaluated. Both surfactants increase the similarities between fluid and protein shape compared to the reference data. While SDBS increases the general lateral spread, PS80 does increase the penetration depth of the protein into the membrane, which could lead to reduced signal in LFAs.