Defining homogeneous units to optimize the monitoring and management of groundwater is a key challenge for organizations responsible for the protection of water for human consumption. However, the number of groundwater bodies (GWBs) is too large for targeted monitoring and recommendations. This study, carried out in the Provence-Alpes-Côte d’Azur region of France, is based on the intersection of two databases, one grouping together the physicochemical and bacteriological analyses of water and the other delimiting the boundaries of groundwater bodies. The extracted dataset contains 8627 measurements from 1143 observation points distributed over 63 GWB. Data conditioning through logarithmic transformation, dimensional reduction through principal component analysis, and hierarchical classification allows the grouping of GWBs into 11 homogeneous clusters. The fractions of unexplained variance (FUV) and ANOVA R2 were calculated to assess the performance of the method at each scale. For example, for the total dissolved load (TDS) parameter, the temporal variance was quantified at 0.36 and the clustering causes a loss of information with an R2 going from 0.63 to 0.4 from the scale of the sampling point to that of the GWB cluster. The results show that the logarithmic transformation reduces the effect of outliers and improves the quality of the GWB clustering. The groups of GWBs are homogeneous and clearly distinguishable from each other. The results can be used to define specific management and protection strategies for each group. The study also highlights the need to take into account the temporal variability of groundwater quality when implementing monitoring and management programs.
When studying large multiparametric databases with very heterogeneous parameters (microbiological, chemical, and physicochemical), covering a wide and heterogeneous area, the probability of observing extreme values (Z-score > 2.5) is high. The information carried by these few samples monopolizes a large part of the information conveyed by the entire database. The study of the spatial structure of the data and the identification of the mechanisms responsible for the water quality are then strongly degraded. Data transformation can be proposed to overcome these problems. This study deals with a database of 8110 groundwater analyses (Occitanie region, France), on which the bacteriological load was measured in Escherichia coli and Enterococci, in addition to electrical conductivity, major ions, Mn, Fe, As and pH. Three modes of data conditioning were tested and compared to the treatment with raw data. The results show that log transformation is the best option, revealing a relationship between E. coli content and all the other parameters. By reducing the impact of extreme values without eliminating them, it allowed a concentration of information on the first factorial axes of the PCA, and consequently a better definition of the associated processes. The spatial structure of the principal components and their cartographic representation is improved. The conditioning of the data with the square root function led to an intermediate improvement between the logarithmic transformation and the absence of conditioning. The application of these results should allow a targeted, more efficient, and therefore, less expensive monitoring of water quality by Regional Health Agencies.
The main landfill in the city of Rabat (Morocco) is based on sandy material containing the shallow Mio-Pliocene aquifer. The presence of a pollution plume is likely, but its extent is not known. Measurements of spontaneous potential (SP) from the soil surface were cross-referenced with direct measurements of the water table and leachates (pH, redox potential, electrical conductivity) according to the available accesses, as well as with an analysis of the landscape and the water table flows. With a few precautions during data acquisition on this resistive terrain, the results made it possible to separate the electrokinetic (~30%) and electrochemical (~70%) components responsible for the range of potentials observed (70 mV). The plume is detected in the hydrogeological downstream of the discharge, but is captured by the natural drainage network and does not extend further under the hills.
In order to facilitate the monitoring of groundwater quality in France, the groundwater bodies (GWB) in the Provence-Alpes-Côte d’Azur region have been grouped into 11 homogeneous clusters on the basis of their physico-chemical and bacteriological characteristics. This study aims to test the legitimacy of this grouping by predicting whether water samples belong to a given sampling point, GWB or group of GWBs. To this end, 8673 observations and 18 parameters were extracted from the Size-Eaux database, and this dataset was processed using discriminant analysis and various machine learning algorithms. The results indicate an accuracy of 67% using linear discriminant analysis and 69 to 83% using ML algorithms, while quadratic discriminant analysis underperforms in comparison, yielding a less accurate prediction of 59%. The importance of each parameter in the prediction was assessed using an approach combining recursive feature elimination (RFE) techniques and random forest feature importance (RFFI). Major ions show high spatial range and play the main role in discrimination, while trace elements and bacteriological parameters of high local and/or temporal variability only play a minor role. The disparity of the results according to the characteristics of the GWB groups (geography, altitude, lithology, etc.) is discussed. Validating the grouping of GWBs will enable monitoring and surveillance strategies to be redirected on the basis of fewer, homogeneous hydrogeological units, in order to optimize sustainable management of the resource by the health agencies.
In many parts of the world, the impact of open landfills on soils, biosphere, and groundwater has become a major concern. These landfills frequently generate pollution plumes, the contours of which can be delineated by non-intrusive geophysical measurements, but in arid environments, the high soils resistivity is usually an obstacle, which results in the low number of studies that have been carried out there. In addition, such prospecting using geophysical techniques do not provide information on the intensity of the processes occurring in the water table. This study was carried out on an uncontrolled landfill in the arid Tadla plain, Morocco’s main agricultural region. A survey based on geo-referenced spontaneous potential measurements was combined with measurements of anoxic conditions (Eh-pH and O2 equilibrating partial pressure) in the groundwater and leachates, in order to highlight a pollution plume and its geometry. The range of spontaneous potential measurement is wide, reaching 155 mV. Ponds of leachate with high electrical conductivity (20 to 40 mS cm−1) form within the landfill, and present very reducing conditions down to sulphate reduction and methanisation. The plume is slowly but continuously supplied with these highly reducing and organic carbon-rich leachates from the landfill. Its direction is towards N-NW, stable throughout the season, and consistent with local knowledge of groundwater flow. The fast flow of the water table suggests pollution over long distances that should be monitored in the future. The results obtained are spatially contrasting and stable, and show that such techniques can be used on a resistive medium of arid environments.
In France, and more generally in Europe, the high number of groundwater bodies (GWB) per administrative region is an obstacle for the management and monitoring of water for human consumption by regional health agencies. Moreover, GWBs show a high spatial, temporal, physico-chemical, and bacteriological variability. The objective is to establish homogeneous groupings of GWB from the point of view of water quality and the processes responsible for this quality. In the Occitanie region in southwestern France, the cross-referencing of two databases, namely the French reference system for groundwater bodies and SISE-EAUX, provided a dataset of 8110 observations and 15 parameters distributed over 106 GWB. The 8-step approach, including data conditioning, dimensional reduction by Principal Component Analysis, and hierarchical clustering, resulted in 20 homogeneous groups of GWB over the whole region. The loss of information caused by this grouping is quantified by the evolution of the explained variance. Splitting the region into two large basins (Adour-Garonne and Rhône Méditerranée) according to the recommendations of the European community does not result in a significant additional loss of information contained in the data. A quick study of a few groups allows to highlight the specificities of each one, thus enabling targeted guidelines or recommendations for water quality management and monitoring. In the future, the method will have to be tested on the scale of large European watersheds, as well as in the context of an increase in the number of parameters.