Sandra Arla Odio

Ms. Sandra Arla Odio

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2017 in INNOVA Research Journal
Verified
Journal Article
Open access
PDF file
SOSandra Arla Odio
Sandra Arla Odio
MZMelton Tapia Zurita
Melton Tapia Zurita
JCJosé Guasumba Codena
José Guasumba Codena
JMJohanna Martí­nEz
Johanna Martí­nEz
JAJulio Asitimbay
Julio Asitimbay
EZEdison Tapia Zurita
Edison Tapia Zurita
El estudio provee información real del recurso energético solar a través de mediciones de la radiación global realizadas en las estaciones meteorológicas, ubicadas a lo largo del trayecto del oleoducto de crudos pesados en 15 puntos de interés en las provincias Nueva Loja, Napo, Pichincha y Esmeraldas, el promedio de estas es comparado con los valores medios obtenidos mediante procedimientos mundialmente utilizados: observaciones por satélite, estimaciones por software y estimaciones por modelos matemáticos. Este estudio pone a disposición de los diseñadores de sistemas de energía solar en Ecuador datos confiables de la radiación solar global, de modo que se puedan dimensionar los sistemas con datos reales y además se tenga conocimiento del grado de error existente al utilizar estos procedimientos; dando a conocer las diferencias encontradas entre los valores medios de radiación determinados por modelos de simulación y de correlación con los medidos en superficie.

19 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
SOSandra Arla Odio
Sandra Arla Odio
RDReinaldo Delgado
Reinaldo Delgado
LGLeonardo Goyos
Leonardo Goyos
Leandro RobainaLeandro Robaina
Leandro Robaina
In this two-phase study, it was shown that a mixture with equal parts of manure and resulting animal blood was the optimal combination for obtaining biogas and biol. A quadratic growth trend in variable gas pressure over time—as well as its behavior—was confirmed for pHs around the neutral value for the substrate used in both the pilot phase and in the microplant, which had a mechanical implementation and mechatronic system for the control of variables that intervene in the anaerobic digestion process; this allowed for the confirmation of the results found in the first phase of research—without concerns that a lack of control over the process variables would cause—in such a way that it constituted a path for the industrialization of the waste treatment process in slaughterhouses that could be optimized by the use of the optimal combination that produces the greatest cm3 amount of gas. Anaerobic digestion in biodigesters is carried out at different constant temperature values within the mesophilic range, with a hydraulic retention time of 25 days. A direct relationship was found between temperature, biogas production and pH behavior in the buffer(s). The pH remained close to neutral and the gas pressure increased from 15 to 20. The findings indicated that the value for the C/N ratio of the blood of four was compensated for by its buffer system, composed of bicarbonate, hemoglobin, proteins and phosphates.

21 May 2025 in Processes
Verified
Journal Article
Open access
PDF file
SOSandra Arla Odio
Sandra Arla Odio
LGLeonardo Goyos
Leonardo Goyos
JMJose L. Mier
Jose L. Mier
The design and operating regime of centrifugal fans operating with contaminated flows must consider the influence of different geometric parameters and flow dynamics design variables on fan wear. The influence of fan rotation speed and blade angle of attack on the erosion wear they may experience when moving fluids contaminated with solid particles is especially relevant. A method is proposed for performing experimental tests that emulate centrifugal fans using a slurry bucket installation, at tangential velocities of 2, 4, and 6 m/s and fluid incidence angles of 16, 22, and 28 degrees. An equation for cumulative wear is found, in which the independent variables incidence angle and linear velocity have a linear and quadratic influence, respectively. It can be specified that when the fan operates at revolutions between 814 and 815 rpm, for a tangential speed of 2 m/s and a flow rate of 20.16 m3/h, an accumulated wear of 1.3124 mg/g is recorded, caused by the impact of solid particles transported by the flow that could impact the surface of the blade when the angle is 22°24′.