Yousef Mazaheri

Dr. Yousef Mazaheri

Department of Medical Physics and Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY 10065, USA

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2008 in Radiology
Verified
Journal Article
Closed access
YMYousef Mazaheri
Yousef Mazaheri
ASAmita Shukla-Dave
Amita Shukla-Dave
HHHedvig Hricak
Hedvig Hricak
SFSamson W. Fine
Samson W. Fine
JZJingbo Zhang
Jingbo Zhang
JKJason A. Koutcher
Jason A. Koutcher
To retrospectively measure the mean apparent diffusion coefficient (ADC) with diffusion-weighted magnetic resonance (MR) imaging and the mean metabolic ratio (MET) with three-dimensional (3D) hydrogen 1 ((1)H) MR spectroscopic imaging in regions of interest (ROIs) drawn over benign and malignant peripheral zone (PZ) prostatic tissue and to assess ADC, MET, and combined ADC and MET for identifying malignant ROIs, with whole-mount histopathologic examination as the reference standard. The institutional review board approved this HIPAA-compliant retrospective study and issued a waiver of informed consent. From among 61 consecutive patients with prostate cancer, 38 men (median age, 61 years; range, 42-72 years) who underwent 1.5-T endorectal MR imaging before radical prostatectomy and who fulfilled all inclusion criteria of no prior hormonal or radiation treatment and at least one PZ lesion (volume, >0.1 cm(3)) at whole-mount pathologic examination were included. ADC maps were generated from diffusion-weighted MR imaging data, and MET maps of (choline plus polyamine plus creatine)/citrate were calculated from 3D (1)H MR spectroscopic imaging data. ROIs in the PZ identified by matching pathologic slides with T2-weighted images were overlaid on MET and ADC maps. Areas under the receiver operating characteristic curves (AUCs) were used to evaluate accuracy. The mean ADC +/- standard deviation, (1.39 +/- 0.23) x 10(-3) mm(2)/sec, and mean MET (0.92 +/- 0.32) for malignant ROIs differed significantly from the mean ADC, (1.69 +/- 0.24) x 10(-3) mm(2)/sec, and mean MET (0.73 +/- 0.18) for benign ROIs (P < .001 for both). In distinguishing malignant ROIs, combined ADC and MET (AUC = 0.85) performed significantly better than MET alone (AUC = 0.74; P = .005) and was also better than ADC alone (AUC = 0.81), although the difference was not statistically significant (P = .09). The combination of ADC and MET performs significantly better than MET for differentiating between benign and malignant ROIs in the PZ.

1 August 2013 in Academic Radiology
Verified
Journal Article
Closed access
YMYousef Mazaheri
Yousef Mazaheri
HVH. Alberto Vargas
H. Alberto Vargas
GNGregory Nyman
Gregory Nyman
OAOguz Akin
Oguz Akin
HHHedvig Hricak
Hedvig Hricak

16 September 2008 in Magnetic Resonance Materials in Physics, Biology and Medicine
Verified
Journal Article
Closed access
PDF file
YMYousef Mazaheri
Yousef Mazaheri
ASAmita Shukla-Dave
Amita Shukla-Dave
AMAda Muellner
Ada Muellner
HHHedvig Hricak
Hedvig Hricak

1 January 2012 in Journal of Computer Assisted Tomography
Verified
Journal Article
Closed access
YMYousef Mazaheri
Yousef Mazaheri
AAAsim Afaq
Asim Afaq
DRDaniel B. Rowe
Daniel B. Rowe
YLYonggang Lu
Yonggang Lu
ASAmita Shukla-Dave
Amita Shukla-Dave
JGJarrett Grover
Jarrett Grover
This study aimed to compare the intraclass correlation coefficients of parameters estimated with stretched exponential and biexponential diffusion models of in vivo diffusion-weighted magnetic resonance imaging (MRI) of the prostate. After the institutional review board issued a waiver of informed consent for this Health Insurance Portability and Accountability Act-compliant study, 25 patients with biopsy-proven prostate cancer underwent 3T endorectal MRI and diffusion-weighted MRI of the prostate at 10 b values (0, 45, 75, 105, 150, 225, 300, 600, 900, and 1200 s/mm). The full set of b values was collected twice within a single acquisition. Intraclass correlation coefficients were calculated for intra-acquisition variability. From the biexponential model, the quantitative parameters diffusion coefficient (D), perfusion coefficient (D*), and perfusion fraction (f) were estimated. From the stretched exponential model, the quantitative parameters Kohlrausch decay constant (DK) and alpha (α) were estimated. For the 25 patient data sets, the average intraclass correlation coefficients for DK and α were 95.8%, and 64.1%, respectively, whereas those for D, D*, and f were 84.4%, 25.3%, and 41.3%, respectively. The stretched exponential diffusion model captures the nonlinear effects of intravoxel incoherent motion in the prostate. The parameters derived from this model are more reliable and reproducible than the parameters derived from the standard, widely used biexponential diffusion/perfusion model.

27 January 2011 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
YMYousef Mazaheri
Yousef Mazaheri
ASAmita Shukla‐Dave
Amita Shukla‐Dave
AMAda Muellner
Ada Muellner
HHHedvig Hricak
Hedvig Hricak

28 December 2017 in World Journal of Radiology
Verified
Journal Article
Open access
YMYousef Mazaheri
Yousef Mazaheri
OAOguz Akin
Oguz Akin
HHHedvig Hricak
Hedvig Hricak
Dynamic contrast-enhanced magnetic resonance imaging of prostate cancer: A review of current methods and applications