Tatiana Khokhlova

Dr. Tatiana Khokhlova


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2014 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
TKTatiana Khokhlova
Tatiana Khokhlova
YWYak-Nam Wang
Yak-Nam Wang
JSJulianna C. Simon
Julianna C. Simon
BCBryan W. Cunitz
Bryan W. Cunitz
FSFrank Starr
Frank Starr
VKVera A. Khokhlova
Vera A. Khokhlova
Significance: High intensity focused ultrasound (HIFU) therapy is a promising, clinically adopted method of noninvasive tissue ablation used to treat both benign and malignant conditions. This work presents, to our knowledge, the first in vivo validation of a previously developed HIFU-based method that allows for noninvasive fractionation of targeted tissue into subcellular debris—boiling histotripsy—in a large animal model. While fractionating the targeted soft tissue, boiling histotripsy is shown to spare the adjacent connective tissue structures such as blood vessels. The process can be readily targeted and monitored by B-mode ultrasound. The resulting tissue debris are liquid, which provides a potential clinical benefit over thermal ablation in the treatment of tumors that exert uncomfortable pressure on surrounding tissues.

1 January 2019 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
GSGeorge R. Schade
George R. Schade
YWYak-Nam Wang
Yak-Nam Wang
SDSamantha D'ANdrea
Samantha D'ANdrea
JHJoo Ha Hwang
Joo Ha Hwang
WLW. Conrad Liles
W. Conrad Liles
TKTatiana Khokhlova
Tatiana Khokhlova

17 July 2023 in International Journal of Hyperthermia
Verified
Journal Article
Open access
RWRandall P. Williams
Randall P. Williams
JSJulianna C. Simon
Julianna C. Simon
VKVera A. Khokhlova
Vera A. Khokhlova
OSOleg A. Sapozhnikov
Oleg A. Sapozhnikov
TKTatiana Khokhlova
Tatiana Khokhlova
Since its inception about two decades ago, histotripsy - a non-thermal mechanical tissue ablation technique - has evolved into a spectrum of methods, each with distinct potentiating physical mechanisms: intrinsic threshold histotripsy, shock-scattering histotripsy, hybrid histotripsy, and boiling histotripsy. All methods utilize short, high-amplitude pulses of focused ultrasound delivered at a low duty cycle, and all involve excitation of violent bubble activity and acoustic streaming at the focus to fractionate tissue down to the subcellular level. The main differences are in pulse duration, which spans microseconds to milliseconds, and ultrasound waveform shape and corresponding peak acoustic pressures required to achieve the desired type of bubble activity. In addition, most types of histotripsy rely on the presence of high-amplitude shocks that develop in the pressure profile at the focus due to nonlinear propagation effects. Those requirements, in turn, dictate aspects of the instrument design, both in terms of driving electronics, transducer dimensions and intensity limitations at surface, shape (primarily, the F-number) and frequency. The combination of the optimized instrumentation and the bio-effects from bubble activity and streaming on different tissues, lead to target clinical applications for each histotripsy method. Here, the differences and similarities in the physical mechanisms and resulting bioeffects of each method are reviewed and tied to optimal instrumentation and clinical applications.

27 December 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TKTatiana Khokhlova
Tatiana Khokhlova
GSGeorge R. Schade
George R. Schade
YWYak-Nam Wang
Yak-Nam Wang
SBSergey Valentinovich Buravkov
Sergey Valentinovich Buravkov
VCValeriy P. Chernikov
Valeriy P. Chernikov
VKVera A. Khokhlova
Vera A. Khokhlova
Boiling histotripsy (BH) is a High Intensity Focused Ultrasound (HIFU) method for precise mechanical disintegration of target tissue using millisecond-long pulses containing shocks. BH treatments with real-time ultrasound (US) guidance allowed by BH-generated bubbles were previously demonstrated ex vivo and in vivo in exposed porcine liver and small animals. Here, the feasibility of US-guided transabdominal and partially transcostal BH ablation of kidney and liver in an acute in vivo swine model was evaluated for 6 animals. BH parameters were: 1.5 MHz frequency, 5–30 pulses of 1–10 ms duration per focus, 1% duty cycle, peak acoustic powers 0.9–3.8 kW, sonication foci spaced 1–1.5 mm apart in a rectangular grid with 5–15 mm linear dimensions. In kidneys, well-demarcated volumetric BH lesions were generated without respiratory gating and renal medulla and collecting system were more resistant to BH than cortex. The treatment was accelerated 10-fold by using shorter BH pulses of larger peak power without affecting the quality of tissue fractionation. In liver, respiratory motion and aberrations from subcutaneous fat affected the treatment but increasing the peak power provided successful lesion generation. These data indicate BH is a promising technology for transabdominal and transcostal mechanical ablation of tumors in kidney and liver.

1 September 2017 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
TKTatiana Khokhlova
Tatiana Khokhlova
YHYasser A. Haider
Yasser A. Haider
AMAdam D. Maxwell
Adam D. Maxwell
WKWayne Kreider
Wayne Kreider
MBMichael R. Bailey
Michael R. Bailey
VKVera A. Khokhlova
Vera A. Khokhlova

26 April 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
CBChristopher R. Bawiec
Christopher R. Bawiec
TKTatiana Khokhlova
Tatiana Khokhlova
OSOleg A. Sapozhnikov
Oleg A. Sapozhnikov
PRPavel B. Rosnitskiy
Pavel B. Rosnitskiy
BCBryan W. Cunitz
Bryan W. Cunitz
VKVera A. Khokhlova
Vera A. Khokhlova
Boiling histotripsy (BH) uses millisecond-long ultrasound (US) pulses with high-amplitude shocks to mechanically fractionate tissue with potential for real-time lesion monitoring by US imaging. For BH treatments of abdominal organs, a high-power multielement phased array system capable of electronic focus steering and aberration correction for body wall inhomogeneities is needed. In this work, a preclinical BH system was built comprising a custom 256-element 1.5-MHz phased array (Imasonic, Besançon, France) with a central opening for mounting an imaging probe. The array was electronically matched to a Verasonics research US system with a 1.2-kW external power source. Driving electronics and software of the system were modified to provide a pulse average acoustic power of 2.2 kW sustained for 10 ms with a 1-2-Hz repetition rate for delivering BH exposures. System performance was characterized by hydrophone measurements in water combined with nonlinear wave simulations based on the Westervelt equation. Fully developed shocks of 100-MPa amplitude are formed at the focus at 275-W acoustic power. Electronic steering capabilities of the array were evaluated for shock-producing conditions to determine power compensation strategies that equalize BH exposures at multiple focal locations across the planned treatment volume. The system was used to produce continuous volumetric BH lesions in ex vivo bovine liver with 1-mm focus spacing, 10-ms pulselength, five pulses/focus, and 1% duty cycle.