Unaiza Uzair

Dr. Unaiza Uzair


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2019 in ACS Sensors
Verified
Journal Article
Closed access
UUUnaiza Uzair
Unaiza Uzair
DBDonald Benza
Donald Benza
CBCaleb J. Behrend
Caleb J. Behrend
JAJeffrey Anker
Jeffrey Anker

12 November 2020 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
UUUnaiza Uzair
Unaiza Uzair
CJChloe Johnson
Chloe Johnson
SBShayesteh Beladi-Behbahani
Shayesteh Beladi-Behbahani
ARApeksha C. Rajamanthrilage
Apeksha C. Rajamanthrilage
YRYash Raval
Yash Raval
JAJeffrey Anker
Jeffrey Anker

2 July 2024 in Chemical & Biomedical Imaging
Verified
Journal Article
Open access
ARApeksha C. Rajamanthrilage
Apeksha C. Rajamanthrilage
UUUnaiza Uzair
Unaiza Uzair
PMPaul W. Millhouse
Paul W. Millhouse
MCMatthew J. Case
Matthew J. Case
DBDonald W. Benza
Donald W. Benza
JAJeffrey Anker
Jeffrey Anker
Measuring chemical concentrations at the surface of implanted medical devices is important for elucidating the local biochemical environment, especially during implant infection. Although chemical indicator dyes enable chemical measurements in vitro, they are usually ineffective when measuring through tissue because the background obscures the dye signal and scattering dramatically reduces the spatial resolution. X-ray excited luminescent chemical imaging (XELCI) is a recent imaging modality which overcomes these limitations using a focused X-ray beam to excite a small spot of red light on scintillator-coated medical implants with well-defined location (because X-rays are minimally scattered) and low background. A spectrochemical indicator film placed over the scintillator layer, e.g., a polymer film containing pH-indicator dyes, absorbs some of the luminescence according to the local chemical environment, and this absorption is then detected by measuring the light intensity/spectrum passing through the tissue. A focused X-ray beam is used to scan point-by-point with a spatial resolution mainly limited by the X-ray beam width with minimum increase from X-ray absorption and scattering in the tissue. X-ray resolution, implant surface specificity, and chemical sensitivity are the three key features of XELCI. Here, we study spatial resolution using optically absorptive targets. For imaging a series of lines, the 20-80% knife-edge resolution was ∼285 (±15) μm with no tissue and 475 ± 18 and 520 ± 34 μm, respectively, through 5 and 10 mm thick tissue. Thus, doubling the tissue depth did not appreciably change the spatial resolution recorded through the tissue. This shows the promise of XELCI for submillimeter chemical imaging through tissue.

23 February 2017
Verified
Conference Paper
Closed access
PDF file
DBDonald Benza
Donald Benza
UUUnaiza Uzair
Unaiza Uzair
YRYash Raval
Yash Raval
Tzuen-Rong TzengTzuen-Rong Tzeng
Tzuen-Rong Tzeng
CBCaleb J. Behrend
Caleb J. Behrend
JAJeffrey Anker
Jeffrey Anker
X-ray excited luminescent chemical imaging (XELCI) uses a combination of X-ray excitation to provide high resolution and optical detection to provide chemical sensing. A key application is to detect and study implant-associated infection. The implant is coated with a layer of X-ray scintillators which generate visible near infrared light when irradiated with an X-ray beam. This light first passes through a pH indicator dye-loaded film placed over the scintillator film in order to modulate the luminescence spectrum according to pH. The light then passes through tissue is collected and the spectral ratio measured to determine pH. A focused X-ray beam irradiates a point in the scintillator film, and a pH image is formed point-by-point by scanning the beam across the sample. The sensor and scanning system are described along with preliminary results showing images in rabbit models.

30 July 2025 in Advanced Healthcare Materials
Verified
Journal Article
Open access
UUUnaiza Uzair
Unaiza Uzair
FWFenglin Wang
Fenglin Wang
DBDonald Benza
Donald Benza
YRYash S. Raval
Yash S. Raval
SBSriparna Bhattacharya
Sriparna Bhattacharya
JAJeffrey Anker
Jeffrey Anker
X‐ray excited luminescence chemical imaging (XELCI) and associated sensor surfaces are designed to noninvasively study, detect, and monitor local chemistry at the surface of modified implanted medical devices during infection. Implants are coated with polymer films containing scintillators and pH indicator dyes that together generate a pH‐dependent luminescence when irradiated by X‐rays. A focused X‐ray beam provides high spatial resolution, while the pH indicator provides chemical sensitivity. A live rabbit pH‐imaging study on a scintillator‐coated implanted titanium plate evaluates the sensor performance with and without Staphylococcus aureus infection and biocompatibility through long‐term histological examinations. 5000 cfu are sufficient to cause infection without fatality. XELCI images clearly shows dye and reference regions in live rabbits; no leaching is evident in titanium plates coated with polyethylene glycol (PEG) hydrogel up to 10 days, although dye leached fromvinyl‐PEG film‐coated implants. No toxicity is evident, and pH sensors remained stable after up to 3 months postimplantation. In these preliminary studies, acidosis is not observed in either infected or control legs in vivo or postmortem. The results demonstrate the feasibility of imaging pH and provide insights for optimizing the sensor and the imaging modality for subsequent studies on pH changes on implants during infection.

2 June 2020 in ChemRxiv
Verified
Preprint
Open access
UUUnaiza Uzair
Unaiza Uzair
CJChloe Johnson
Chloe Johnson
SBShayesteh Beladi-Behbahani
Shayesteh Beladi-Behbahani
DBDonald Benza
Donald Benza
YRYash Raval
Yash Raval
JAJeffrey Anker
Jeffrey Anker
We describe a material that allows for high spatial resolution pH mapping through tissue using X-ray excited luminescence chemical imaging (XELCI). This is especially useful for detecting implant associated infection and elucidating how the local biochemical environment changes during infection and treatment. To acquire one pixel in the image, a focused X-ray beam irradiates a small region of scintillators coated on the implant and the X-ray excited optical luminescence spectrum is modulated by indicator dyes to provide a chemically sensitive measurement with low background. Scanning the X-ray beam across the implant surface generates high spatial resolution chemical measurements. Two associated challenges are 1) to make robust sensors that can be implanted in tissue to measure local chemical concentrations and specifically for metal orthopedic implants, and 2) to conformally coat the implant surface with scintillators and pH indicator dyes in order to make measurements over a large area. Previously, we have physically pressed or glued a pH-sensitive hydrogel sensor to the surface of an implant, but this is impractical for imaging over large irregular device areas such as an orthopedic plate with holes and edges. Herein we describe a chemically sensitive and biocompatible XELI sensor material containing scintillator particles (Gd2O2S:Eu) and a pH sensitive hydrogel coating using a roughened epoxy coating. A two-part commercial grade epoxy film was tested and found to make the coating of pH sensitive layer adhere better to the titanium surface. Sugar and salt particles were added to the surface of the epoxy as it cured to create a roughened surface and increase surface area. On this roughened surface, a secondary layer of diacrylated polyethylene glycol (PEG) hydrogel, containing a pH sensitive dye, was polymerized. This layer was found to adhere well to the epoxy-coated implant unlike other previously tested polymer surfaces which delaminated when exposed to water or humidity. The focused X-ray beam enabled 0.5 mm spatial resolution through 1 cm thick tissue. The pH sensor coated orthopedic plate was imaged with XELCI through tissue with different pH to acquire a calibration curve. The plates were also imaged through tissue with low pH region from a Staphylococcus aureus biofilm grown on one section. These studies demonstrate the use of pH sensor coated orthopedic plates for mapping the surface pH through tissue during biofilm formation using XELCI.