Guocheng Wang

Prof. Dr. Guocheng Wang

Research Center for Human Tissues and Organs Degeneration, Shenzhen Institute of Advanced Technology, CAS, Shenzhen, China
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2013 in Biomaterials
Verified
Journal Article
Closed access
WZWenjie Zhang
Wenjie Zhang
GWGuocheng Wang
Guocheng Wang
YLYan Liu
Yan Liu
XZXiaobing Zhao
Xiaobing Zhao
DZDuohong Zou
Duohong Zou
HZHala Zreiqat
Hala Zreiqat

10 September 2021 in Materials Advances
Verified
Journal Article
Open access
PDF file
GZGuang Zhu
Guang Zhu
GWGuocheng Wang
Guocheng Wang
Jiao Jiao LiJiao Jiao Li
Jiao Jiao Li
Metallic biomaterials are widely used in implants to strengthen, repair, or replace damaged bone tissue, and their material characteristics have direct influences on short- and long-term implant performance. Of these, titanium and its alloys are the most widely applied due to their superior corrosion resistance, biocompatibility, and mechanical properties, such as in joint replacements, dental implants, and spinal fusion cages. However, Ti and Ti alloys are bioinert materials that have difficulty in binding directly to bone tissue after implantation, due to a lack of osteoconductive and osteoinductive properties. Bacterial adhesion and colonisation at the implantation site may also lead to infection-associated complications. The surface of the titanium implant directly interfaces with blood, cells, and tissues in vivo, and the surface properties can have profound influences on protein- and cell-based interactions that then promote or impede osseointegration. Therefore, the material surface morphology, chemistry and antibacterial function are key parameters in implant design, and contribute to determining the long-term success of the implant. In this review, we systematically present the latest advances in surface modification techniques for orthopaedic implants, including mechanical, physical, chemical, and biological modification. We also analyse and compare different surface modification approaches, including drug loading, metallic element doping, and bionic coatings, as well as topographical modifications such as nanotubes, nanopores and nanowires. Finally, we present a critical analysis and future perspectives on the use of surface modifications to improve the osseointegration and antibacterial properties of orthopaedic implants.

3 January 2023 in Advanced Science
Verified
Journal Article
Open access
QCQiaoqiao Ci
Qiaoqiao Ci
YWYuanyuan Wang
Yuanyuan Wang
BWBen Wu
Ben Wu
Emerson CoyEmerson Coy
Emerson Coy
Jiao Jiao LiJiao Jiao Li
Jiao Jiao Li
GWGuocheng Wang
Guocheng Wang
Carbon dots (CDs) with excellent cytocompatibility, tunable optical properties, and simple synthesis routes are highly desirable for use in optical bioimaging. However, the majority of existing CDs are triggered by ultraviolet/blue light, presenting emissions in the visible/first near‐infrared (NIR‐I) regions, which do not allow deep tissue penetration. Emerging research into CDs with NIR‐II emission in the red region has generated limited designs with poor quantum yield, restricting their in vivo imaging applications due to low penetration depth. Developing novel CDs with NIR‐II emissions and high quantum yield has significant and far‐reaching applications in bioimaging and photodynamic therapy. Here, it is developed for the first time Fe‐doped CDs (Fe‐CDs) exhibiting the excellent linear relationship between 900–1200 nm fluorescence‐emission and pH values, and high quantum yield (QY‐1.27%), which can be used as effective probes for in vivo NIR‐II bioimaging. These findings demonstrate reliable imaging accuracy in tissue as deep as 4 mm, reflecting real‐time pH changes comparable to a standard pH electrode. As an important example application, the Fe‐CDs probe can non‐invasively monitor in vivo gastric pH changes during the digestion process in mice, illustrating its potential applications in aiding imaging‐guided diagnosis of gastric diseases or therapeutic delivery.

1 May 2009 in Acta Biomaterialia
Verified
Journal Article
Closed access
JSJunying Sun
Junying Sun
LWLi Wei
Li Wei
XLXuanyong Liu
Xuanyong Liu
JLJianyou Li
Jianyou Li
BLBaoe Li
Baoe Li
FMFanhao Meng
Fanhao Meng

9 July 2010 in Materials
Verified
Journal Article
Open access
PDF file
GWGuocheng Wang
Guocheng Wang
Hala  ZreiqatHala Zreiqat
Hala Zreiqat
Metallic biomaterials like stainless steel, Co-based alloy, Ti and its alloys are widely used as artificial hip joints, bone plates and dental implants due to their excellent mechanical properties and endurance. However, there are some surface-originated problems associated with the metallic implants: corrosion and wear in biological environments resulting in ions release and formation of wear debris; poor implant fixation resulting from lack of osteoconductivity and osteoinductivity; implant-associated infections due to the bacterial adhesion and colonization at the implantation site. For overcoming these surface-originated problems, a variety of surface modification techniques have been used on metallic implants, including chemical treatments, physical methods and biological methods. This review surveys coatings that serve to provide properties of anti-corrosion and anti-wear, biocompatibility and bioactivity, and antibacterial activity.

30 November 2021 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
MYMinggang Yang
Minggang Yang
SQShi Qiu
Shi Qiu
Emerson CoyEmerson Coy
Emerson Coy
SLShuaijie Li
Shuaijie Li
KZKarol Załęski
Karol Załęski
GWGuocheng Wang
Guocheng Wang