The aim of this study was to investigate, over a period of approximately 3 years, the reactions to orthodontic loading of a type V titanium miniscrew. In this retrospective study, conducted in a private practice, the records of 300 miniscrews inserted in 132 consecutive patients (80 females, 60.6 per cent) by the same surgeon were evaluated. The mean age of the patients was 23.2 years. Three types of miniscrews (type A: diameter 1.5 mm, length 9 mm; type B: diameter 1.5 mm, length 11 mm; and type C: diameter 1.3 mm, length 11 mm) were used. The clinical variables evaluated included the loading time and location of the miniscrew in relation to the gingiva and root. The success rates with different variables were compared using chi-square or Fisher’s exact test where appropriate. A cumulative survival rate of 81 per cent (243/300) was found using Kaplan–Meier analysis, with an optimum success rate for the 1.3 mm wide miniscrew inserted in the attached gingiva, with immediate loading applied. Cox proportional hazard regression showed significant differences between success rate and the following parameters: gender, loading time, gingival or bone localization, and diameter of the miniscrews. Considering the clinically controllable parameters, and within the limits of this retrospective study, 1.3 mm diameter miniscrews inserted in attached gingiva and immediately loaded had the most favourable prognosis.
Several studies have recently demonstrated that a post-treatment communication to explain the importance of an oral hygiene can improve the orthodontic patients’ compliance over a period of 66 days. The main goal of this study is to evaluate the effects of a structured follow-up communication after orthodontic appliance application on oral hygiene compliance after 30–40 days. Eighty-four orthodontic participants enrolled from patients who were beginning fixed orthodontic treatment at the Orthodontic Department, Gaslini Hospital, Genova, between July and October 2014 were randomly assigned to one of three trial arms. Before the bonding, all patients underwent a session of oral hygiene aimed at obtaining an plaque index of “zero.” At the following orthodontic appointment, the plaque index was calculated for each patient in order to assess oral hygiene compliance. The first group served as control and did not receive any post-procedure communication, the second group received a structured text message giving reassurance, and the third group received a structured telephone call. Participants were blinded to group assignment and were not made aware that the text message or the telephone call was part of the study. (The research protocol was approved by the Italian Comitato Etico Regionale della Liguria-sezione 3^ c/o IRCCS-Istituto G. Gaslini 845/2014, and it is not registered in the trial’s register.) Thirty patients were randomly assigned to the control group, 28 participants to the text message group, and 26 to the telephone group. Participants who received a post-treatment communication reported higher level of oral hygiene compliance than participants in the control group. The plaque index was 0.3 (interquartile range (Iqr), 0.60) and 0.75 (Iqr, 1.30), respectively, with a significant difference (P = 0.0205). A follow-up procedure after orthodontic treatment may be an effective tool to increase oral hygiene compliance also over a short period.
15 December 2008 in European Journal of Orthodontics
The aims of this study were to analyse the stress distribution developing around an orthodontic miniscrew (OM) inserted into the maxilla and to determine the stress field changes for different screw lengths and for different levels of osseointegration occurring at the bone/screw interface. An integrated experimental/numerical approach was adopted. Using the photoelastic technique, the stress field arising in the bone after screw insertion and the application of the initial orthodontic load was assessed. The finite element (FE) method was used to determine the stress acting in the bony tissue after a given time following screw application, when, for the viscoelastic relaxation effects, the only stress field remaining was that due to the application of the orthodontic load. Different levels of osseointegration were hypothesized. Photoelastic analyses showed that stress distribution does not change significantly for moderate initial orthodontic loads. From the FE simulations, it was found that critical conditions occur for screws 14 mm long with an orthodontic load of 2 N. The optimal screw length seems to be 9 mm. For such a dimension, small stress values were found as well as low risk of lesion to the anatomical structures.