Jianyu Li

Jianyu Li


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Clinical Neurology and Neurosurgery
Verified
Journal Article
Closed access
KYKaijia Yu
Kaijia Yu
ZRZhiwei Ren
Zhiwei Ren
SGSong Guo
Song Guo
JLJianyu Li
Jianyu Li
YLYongjie Li
Yongjie Li

14 January 2022 in Acta Neurochirurgica
Verified
Journal Article
Closed access
PDF file
KYKaijia Yu
Kaijia Yu
ZRZhiwei Ren
Zhiwei Ren
YHYongsheng Hu
Yongsheng Hu
SGSong Guo
Song Guo
XYXiaofan Ye
Xiaofan Ye
YLYongjie Li
Yongjie Li

11 July 2022 in Brain Sciences
Verified
Journal Article
Open access
PDF file
SMShanshan Mei
Shanshan Mei
KYKaijia Yu
Kaijia Yu
ZRZhiwei Ren
Zhiwei Ren
YHYongsheng Hu
Yongsheng Hu
SGSong Guo
Song Guo
JLJianyu Li
Jianyu Li
Background: Frameless robot-assisted deep brain stimulation (DBS) is an innovative technique for leads implantation. This study aimed to evaluate the accuracy and precision of this technique using the Sinovation SR1 robot. Methods: 35 patients with Parkinson’s disease who accepted conventional frame-based DBS surgery (n = 18) and frameless robot-assisted DBS surgery (n = 17) by the same group of neurosurgeons were analyzed. The coordinate of the tip of the intended trajectory was recorded as xi, yi, and zi. The actual position of lead implantation was recorded as xa, ya, and za. The vector error was calculated by the formula of √(xi − xa)2 + (yi − ya)2 + (zi − za)2 to evaluate the accuracy. Results: The vector error was 1.52 ± 0.53 mm (range: 0.20–2.39 mm) in the robot-assisted group and was 1.77 ± 0.67 mm (0.59–2.98 mm) in the frame-based group with no significant difference between two groups (p = 0.1301). In 10.7% (n = 3) frameless robot-assisted implanted leads, the vector error was greater than 2.00 mm with a maximum offset of 2.39 mm, and in 35.5% (n = 11) frame-based implanted leads, the vector error was larger than 2.00 mm with a maximum offset of 2.98 mm. Leads were more posterior than planned trajectories in the robot-assisted group and more medial and posterior in the conventional frame-based group. Conclusions: Awake frameless robot-assisted DBS surgery was comparable to the conventional frame-based technique in the accuracy and precision for leads implantation.

5 July 2021 in Frontiers in Neuroscience
Verified
Journal Article
Open access
KYKaijia Yu
Kaijia Yu
ZRZhiwei Ren
Zhiwei Ren
TYTao Yu
Tao Yu
XWXueyuan Wang
Xueyuan Wang
YHYongsheng Hu
Yongsheng Hu
YLYongjie Li
Yongjie Li
Objective: Deep brain stimulation (DBS) of the anterior nucleus of the thalamus (ANT) is a potentially effective, minimally invasive, and reversible method for treating epilepsy. The goal of this study was to explore whether 3 T quantitative susceptibility mapping (QSM) could delineate the ANT from surrounding structures, which is important for the direct targeting of DBS surgery.Methods: We obtained 3 T QSM, T1-weighted (T1w), and T2-weighted (T2w) images from 11 patients with Parkinson’s disease or dystonia who received subthalamic nucleus (STN) or globus pallidus interna (GPi) DBS surgery in our center. The ANT and its surrounding white matter structures on QSM were compared with available atlases. The contrast-to-noise ratios (CNRs) of ANT relative to the external medullary lamina (eml) were compared across the three imaging modalities. Additionally, the morphology and location of the ANT were depicted in the anterior commissure (AC)-posterior commissure (PC)-based system.Results: ANT can be clearly distinguished from the surrounding white matter laminas and appeared hyperintense on QSM. The CNRs of the ANT-eml on QSM, T1w, and T2w images were 10.20 ± 4.23, 1.71 ± 1.03, and 1.35 ± 0.70, respectively. One-way analysis of variance (ANOVA) indicated significant differences in CNRs among QSM, T1w, and T2w imaging modalities [F(2) = 85.28, p < 0.0001]. In addition, both the morphology and location of the ANT were highly variable between patients in the AC–PC-based system.Conclusion: The potential utility of QSM for the visualization of ANTs in clinical imaging is promising and may be suitable for targeting the ANT for DBS to treat epilepsy.

6 June 2022 in Frontiers in Neurology
Verified
Journal Article
Open access
XWXue Wang
Xue Wang
SMShanshan Mei
Shanshan Mei
ZTZichen Tian
Zichen Tian
LWLin Wang
Lin Wang
GHGuiliang Hao
Guiliang Hao
JLJianyu Li
Jianyu Li
Dopa-responsive dystonia (DRD) is a group of movement disorders with genetic and clinical heterogeneity. Dramatic response to levodopa is the hallmark of DRD. Therefore, DRD cases with poor response to levodopa are rarely reported. In addition, the clinical outcomes from deep brain stimulation (DBS) in levodopa-resistant patients remain unclear. Here, we described the clinical outcome of pallidal stimulation in a DRD patient having a poor response to levodopa. The patient was a 25-year-old man and had a 7-year history of cervical dystonia. A novel frameshift mutation in the GCH1 gene was found in the patient as well as his elder sister and mother. Unfortunately, he had no response to a large dosage of levodopa/benserazide (600/150 mg per day) and onabotulinumtoxin A injection. Therefore, bilateral globus pallidus internus (GPi) deep brain stimulation (DBS) was performed. With parameter adjustments, the severity of his torticollis was gradually improved and relieved substantially in the 8-month follow-up visit. Our current report highlights that GPi-DBS therapy leads to promising clinical outcomes for levodopa-resistant DRD.