Chengli Qi

Ms. Chengli Qi


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2020 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
CQChengli Qi
Chengli Qi
CWChunqiang Wu
Chunqiang Wu
XHXiuqing Hu
Xiuqing Hu
HXHanlie Xu
Hanlie Xu
LLLu Lee
Lu Lee
Peng ZhangPeng Zhang
Peng Zhang

1 June 2020 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
CWChunqiang Wu
Chunqiang Wu
CQChengli Qi
Chengli Qi
XHXiuqing Hu
Xiuqing Hu
MGMingjian Gu
Mingjian Gu
TYTianhang Yang
Tianhang Yang
Peng ZhangPeng Zhang
Peng Zhang
The High-Spectral Infrared Atmospheric Sounder (HIRAS) is a Fourier transform spectrometer onboard the fourth polar-orbiting FengYun 3D satellite (FY-3D). The FY-3D HIRAS provides interferogram measurements of Earth view radiance spectra in three infrared spectral bands at 29 cross-track positions, each with a 2 x p 2 array of field of views (FOVs). The HIRAS level 1 radiance data cover the spectral bands from 650 to 1135 cm⁻¹ [long-wave (LW) band], 1210 to 1750 cm⁻¹ [mid-wave (MW) band], and 2155 to 2550 cm⁻¹ [short-wave (SW) band] with a spectral resolution of 0.625 cm⁻¹. The radiometric calibration algorithm and the methods of refining the nonlinearity (NL) and the polarization correction coefficients on orbit are summarized in this article. The NL correction coefficients are derived by minimizing the spread of the responsivity functions derived from the measurements of the internal calibration target with varying temperatures. The polarization correction coefficients are derived from the cold space observations and the routine Earth scene measurements. The radiometric accuracy is assessed by comparing the HIRAS measurements to the collocated Cross-track Infrared Sounder (CrIS) observations and radiance simulations. The results show that, compared to CrIS, the radiometric differences are about 0.3 and 0.7 K for the LW and MW bands, respectively, and 0.5 K for the CO absorption and window regions in the SW band. The consistency of the radiometric calibration among the four FOVs is estimated to be within 0.2 K for most of the spectral domain. Some remaining issues for the FY-3D HIRAS are also discussed.

22 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
GYGuanglin Yang
Guanglin Yang
XDXiaoyong Du
Xiaoyong Du
LHLingyong Huang
Lingyong Huang
Xuerui WuXuerui Wu
Xuerui Wu
Ling SunLing Sun
Ling Sun
SSShaohui Song
Shaohui Song
An effective soil moisture retrieval method for FY-3E (Fengyun-3E) GNOS-R (GNSS occultation sounder II-reflectometry) is developed in this paper. Here, the LAGRS model, which is totally oriented for GNOS-R, is employed to estimate vegetation and surface roughness effects on surface reflectivity. Since the LAGRS (land surface GNSS reflection simulator) model is a space-borne GNSS-R (GNSS reflectometry) simulator based on the microwave radiative transfer equation model, the method presented in this paper takes more consideration on the physical scattering properties for retrieval. Ancillary information from SMAP (soil moisture active passive) such as the vegetation water content and the roughness coefficient are investigated for the final algorithm’s development. At first, the SR (surface reflectivity) data calculated from GNOS-R is calculated and then calibrated, and then the vegetation roughness factor is achieved and used to eliminate the effects on both factors. After receiving the Fresnel reflectivity, the corresponding soil moisture estimated from this method is retrieved. The results demonstrate good consistency between soil moisture derived from GNOS-R data and SMAP soil moisture, with a correlation coefficient of 0.9599 and a root mean square error of 0.0483 cm3/cm3. This method succeeds in providing soil moisture on a global scale and is based on the previously developed physical LAGRS model. In this way, the great potential of GNOS-R for soil moisture estimation is presented.

4 July 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Chunming ZhangChunming Zhang
Chunming Zhang
CQChengli Qi
Chengli Qi
Tianhang YangTianhang Yang
Tianhang Yang
MGMingjian Gu
Mingjian Gu
ZXzhang pan xiang
zhang pan xiang
XHXiuqing Hu
Xiuqing Hu
Before infrared hyperspectral data are used in satellite data assimilation systems or retrieval systems, the quantitative analysis of data deviation is necessary. Based on RTTOV’s (Radiative Transfer for TOVS) simulation data of FY-3E/HIRAS-II (Hyperspectral Infrared Atmospheric Sounder) and the observation data of HIRAS-II, we counted the bias of observation minus simulation (OMB) during an on-orbit test; analyzed the characteristics and reasons for the bias from the perspective of the FOV (field of view), the scanning angle of the instrument, the day and night, and the target temperature change; and analyzed the stability of the radiometric calibration accuracy. We also combined the results of the MetOp-C/IASI (infrared atmospheric sounding interferometer), a similar high-precision instrument, with the bias of OMB to compare and evaluate the FY-3E/HIRAS-II radiometric calibration accuracy. In the end, we found that the mean OMB bias of the long-wave and medium-wave infrared bands is within ±2 K, and the bias standard deviation is better than 2 K; the bias of each FOV is consistent and the bias of most channels is better than 2 K. The OMB bias of each channel is consistent with the changes in the angle of the instrument. The bias trend of long-wave and medium-wave infrared channels is more consistent with the deviation of the day and night; the bias of the short-wave infrared channel at night is lower than in the daytime. When counting the bias as the target temperature changed, the results showed that there are no obvious temperature dependencies in the long-wave and medium-wave infrared channels. This reflects that the instrument’s non-linear effect is well ordered. We further evaluated the stability of the radiometric calibration accuracy through statistics from the OMB standard deviation of each channel of FY-3E/HIRAS-II. Most channel accuracy stability values were better than 0.1 K. We calculated that IASI and HIRAS-II OMB have double differences, and the results show that the double difference in most channels is better than 1 K. It shows that the HIRAS-II and IASI observations are highly consistent. Through the statistics of the OMB bias during the on-orbit test period of FY-3E/HIRAS-II, we fully evaluated its radiometric calibration accuracy and laid the foundation for FY-3E/HIRAS-II data to be used in the retrieval application and assimilation system.

22 February 2023 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
WBWenguang Bai
Wenguang Bai
Peng ZhangPeng Zhang
Peng Zhang
HLHui Liu
Hui Liu
WZWenjian Zhang
Wenjian Zhang
CQChengli Qi
Chengli Qi
GLGuannan Li
Guannan Li
A fast piecewise-defined neural network (PDNN) method is presented to produce accurate atmospheric temperature and humidity profiles from satellite hyperspectral infrared and microwave observations in all-sky conditions. The PDNN method relies on a novel classification approach and a principal component-based neural network function to better capture the nonlinear relationship between the spectral radiances and atmospheric state vectors. The algorithm was designed to only rely on satellite measurements. Large datasets were used for network training to make the retrieval robust to random errors in the reference data. For each retrieved profile, an effective quality indicator was obtained by training against the absolute value of the retrieval error. In addition, a reliable rain cloud flag was generated based on the scattering difference of cloud particles between the 50 and 118 GHz channels. Besides the independent reanalysis field data, the algorithm’s performance was also evaluated using radiosonde measurements. Preliminary validation shows that the best temperature retrieval occurred in the mid-troposphere (around 1.0 K). Depending on the reference data, errors in the boundary layer typically ranged from 1.8 K to 2.5 K. For water vapor, the retrieval error was less than 22% in the low-troposphere and less than 35% in the mid-and upper-troposphere when validated against the reanalysis field. The humidity error was approximately 10% lower when compared to radiosondes. The PDNN is used operationally to produce atmospheric temperature and moisture soundings from the Vertical Atmospheric Sounding System of the FengYun-3E satellite, an early-morning-orbit meteorological satellite launched in 2021.

17 November 2023 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
JHJuyang Hu
Juyang Hu
WCWenxin Chen
Wenxin Chen
JCJidong Chi
Jidong Chi
LSLing Sun
Ling Sun
XHXiuqing Hu
Xiuqing Hu
CQChengli Qi
Chengli Qi
The third generation of MicroWave Temperature Sounder (MWTS-III) is a major payload of FengYun-3F (FY-3F) satellite, which was launched on August 3, 2023. It can provide valuable atmospheric temperature profiles in morning time for numerical weather prediction (NWP) applications. The prelaunch thermal vacuum (TVAC) calibration test was performed to examine the instrument quality. This paper briefly describes of the instrument design of MWTS-III and details the TVAC tests calibration methodology and radiometric performance, including sensitivity, striping, nonlinearity, and calibration accuracy. Channels 1 and 2, which are received by direct-detection receivers, have a noise equivalent delta temperature (NEDT) of less than 0.2K, weak correlations with other channels, striping indexes (SI) of 1.0 and 1.2, small peak nonlinearity and calibration residual errors within ±0.03K. The NEDT for Channels 3-17 is 0.16 K-1.38 K. The inter-channel correlation and striping phenomena are more significant for these 15 channels. Since the linear calibration deviations were well mitigated by the nonlinear calibration, the calibration residual errors for channels 3-11 are within ±0.05 K and for channels 12-17 are within ±0.17 K. The predicted on-orbit calibration accuracy for all channels are between 0.37 K and 1.48K. In summary, all channels of FY-3F MWTS-III meet the specifications, and the instrument has great application potential.