Nina Lümkemann

Ms. Nina Lümkemann


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2017 in Materials
Verified
Journal Article
Open access
PDF file
NLNina Lümkemann
Nina Lümkemann
MEMarlis Eichberger
Marlis Eichberger
Bogna StawarczykBogna Stawarczyk
Bogna Stawarczyk
This study investigated the impact of different light curing units (LCUs) for the polymerization of adhesive system visio.link (VL) on the tensile bond strength (TBS) of different PEEK compositions. For TBS measurements, 216 PEEK specimens with varying amounts of TiO2 (PEEK/0%, PEEK/20%, PEEK/>30%) were embedded, polished, air abraded (Al2O3, 50 µm, 0.4 MPa), conditioned using VL, and polymerized using either a halogen LCU (HAL-LCU) or a LED LCU (LED-LCU) for chairside or labside application, respectively. After thermocycling (5000×, 5/55 °C), TBS was measured, and fracture types were determined. Data was analyzed using a 2-way ANOVA followed by Tukey–HSD, Kruskal–Wallis H and Mann–Whitney U tests as well as a Chi2-test and a Ciba–Geigy table (p < 0.05). Globally, the light curing units, followed by PEEK composition, was shown to have the highest impact on TBS. The HAL-LCUs, compared to the LED-LCUs, resulted in a higher TBS for all PEEK compositions—without significant differences between chairside and labside units. Regarding the different PEEK compositions, PEEK/20%, compared to PEEK/0%, resulted in a higher TBS when both, HAL-LCUs or LED-LCUs were used for labside application. In comparison with PEEK/>30%, PEEK/20% resulted in a higher TBS after using HAL-LCU for labside application. No significant differences were found between PEEK/0% and PEEK/>30%. HAL-LCU with PEEK/20% for labside application showed a higher TBS than HAL-LCU with PEEK/20% for chairside application, whereas LED-LCU with PEEK/>30% for chairside application showed a higher TBS than LED-LCU with PEEK/>30% for labside application.

19 December 2017 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Bogna StawarczykBogna Stawarczyk
Bogna Stawarczyk
NLNina Lümkemann
Nina Lümkemann
MEMarlis Eichberger
Marlis Eichberger
TWTimea Wimmer
Timea Wimmer
The purpose of this investigation was to analyze the accuracy of digitally fabricated wax trial dentures and conventionally finalized complete dentures in comparison to a surface tessellation language (STL)-dataset. A generated data set for the denture bases and the tooth sockets was used, converted into STL-format, and saved as reference. Five mandibular and 5 maxillary denture bases were milled from wax blanks and denture teeth were waxed into their tooth sockets. Each complete denture was checked on fit, waxed onto the dental cast, and digitized using an optical laboratory scanning device. The complete dentures were completed conventionally using the injection method, finished, and scanned. The resulting STL-datasets were exported into the three-dimensional (3D) software GOM Inspect. Each of the 5 mandibular and 5 maxillary complete dentures was aligned with the STL- and the wax trial denture dataset. Alignment was performed based on a best-fit algorithm. A three-dimensional analysis of the spatial divergences in x-, y- and z-axes was performed by the 3D software and visualized in a color-coded illustration. The mean positive and negative deviations between the datasets were calculated automatically. In a direct comparison between maxillary wax trial dentures and complete dentures, complete dentures showed higher deviations from the STL-dataset than the wax trial dentures. The deviations occurred in the area of the teeth as well as in the distal area of the denture bases. In contrast, the highest deviations in both the mandibular wax trial dentures and the mandibular complete dentures were observed in the distal area. The complete dentures showed higher deviations on the occlusal surfaces of the teeth compared to the wax dentures. Computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated wax dentures exhibited fewer deviations from the STL-reference than the complete dentures. The deviations were significantly greater in the vicinity of the denture teeth area and the bases. The conventional transfer of CAD/CAM-fabricated wax dentures into acrylic resin leads to the highest deviations from the STL-reference.

29 March 2021 in Materials
Verified
Journal Article
Open access
PDF file
MKMarietta Kreutz
Marietta Kreutz
AWAnnette Wiegand
Annette Wiegand
Bogna StawarczykBogna Stawarczyk
Bogna Stawarczyk
NLNina Lümkemann
Nina Lümkemann
MRMarta Rizk
Marta Rizk
The use of functionalized dental adhesives that might prevent degradation of the dentin hybrid layer has been proposed. The aim of the study was to characterize the physicochemical properties and the potential to induce mineral precipitation of methacrylate-based resins containing methacryl-functionalized polyhedral oligomeric silsesquioxane (MA-POSS-8). In total, six different compositions of resins based on bisphenol A glycerolate dimethacrylate (BisGMA, 40 to 60 wt.%), triethylene glycol dimethacrylate (TEGDMA, 5 to 35 wt.%) and 2-hydroxyethyl methacrylate (HEMA, 25 or 35 wt.%) were prepared and infiltrated with 5 wt.% MA-POSS-8. Unfilled resins served as control. Degree of conversion, viscosity, Martens hardness, indentation modulus, water sorption, and sol fraction were investigated. Polymerized specimens were examined by SEM/EDX for the presence of Ca/P precipitates after immersion in artificial saliva for 28 days at 37 °C. Statistical analysis was performed with two-way ANOVA and Tukey’s post-hoc test (p < 0.05). The degree of conversion ranged from 55.0 to 59.8% and was not affected by the addition of MA-POSS-8. Viscosity ranged from 60.0 to 422.3 mPa*s and was not affected by MA-POSS-8 except for one methacrylate-based resin with 60 wt.% BisGMA. Martens hardness and indentation modulus ranged from 161.3 to 138.1 N/mm2 and 4.2 to 3.9 kN/mm2 and were affected by MA-POSS-8 in only one resin (50 wt.% BisGMA, 25 wt.% TEGDMA, 25 wt.% HEMA). Water sorption was not affected by MA-POSS-8; sol fraction was below the detection limit. Formation of Ca/P precipitates was observed on all specimens of test and control groups. Material properties were not affected adversly by MA-POSS-8 except for slight differences in Martens Hardness, indentation modulus, viscosity, in some groups.

5 July 2023 in Materials
Verified
Journal Article
Open access
PDF file
NLNina Lümkemann
Nina Lümkemann
MKMelisa Klimenta
Melisa Klimenta
MHMoritz Hoffmann
Moritz Hoffmann
JMJohn Meinen
John Meinen
Bogna StawarczykBogna Stawarczyk
Bogna Stawarczyk
To test the impact of FFF filaments, printing parameters, thermoforming foils, repeated thermoforming cycles, and type of jaw on the dimensional stability of FFF models for aligners and to compare them with plaster models, FFF models (maxilla, n = 48; mandible, n = 48) from two filaments (SIMPLEX aligner and Renfert PLA HT, both Renfert GmbH) were fabricated using four printing parameters (one, two, or three loops; four loops acted as the default) and conventional plaster models (n = 12) based on a young, female dentition. All models were thermoformed under pressure three times in total using two different thermoforming foils, namely 0.75 mm × 125 mm Ø aligner foil (CA Pro+ Clear Aligner, Scheu Dental) and 1.0 mm × 125 mm Ø Duran foil (Duran+, Scheu Dental). Aligner foil was heated at 220 °C for 25 s and Duran foil at 220 °C for 30 s. All models were scanned after fabrication as well as after each thermoforming cycle. The obtained STL datasets were analyzed using the local best-fit method (GOM Inspect Pro, Carl Zeiss Metrology GmbH). Data were analyzed using a Kolmogorov–Smirnov-test, a one-way ANOVA with post-hoc Scheffé, and a t-test (p < 0.05). The dimensional stability of the models was most strongly affected by the printing parameters (number of loops; ηp2 = 0.768, p < 0.001) followed by the thermoforming foil used (ηp2 = 0.663, p < 0.001) as well as the type of model (ηp2 = 0.588, p < 0.001). In addition, various interactions showed an influence on the dimensional stability (ηp2 = 0.041–0.386, p < 0.035). SIMPLEX maxillary models (default; four loops), thermoformed using aligner foil, showed higher deformation stability than did plaster models. These initial FFF models provide comparable precision to plaster models, but the dimensional stability of the FFF models, in contrast to that of plaster models, decreases with increasing numbers of thermoforming cycles.

18 September 2020 in Materials
Verified
Journal Article
Open access
PDF file
NLNina Lümkemann
Nina Lümkemann
LSLisa Marie Schönhoff
Lisa Marie Schönhoff
RBRamona Buser
Ramona Buser
Bogna StawarczykBogna Stawarczyk
Bogna Stawarczyk
The present investigation tested the effect of the cleaning method on the tensile bond strength (TBS) between one resin composite cement (RCC) and three different computer aided design/computer aided manufacturing (CAD/CAM) materials, namely zirconia, lithium disilicate ceramic and resin composite. Ninety specimens were prepared from each CAD/CAM material (N = 270). The specimens were pre-treated respectively, divided into five subgroups and subjected to five different cleaning protocols, namely i. 37% phosphoric acid, ii. ethanol, iii. phosphoric acid + ethanol, iv. cleaning paste, v. distilled water. After cleaning, the specimens were either conditioned using a universal primer or a universal adhesive and bonded using a dual-curing RCC. After thermo-cycling (20,000x at 5 °C/55 °C), TBS and fracture patterns were evaluated. The data was analyzed using 1- and 2-way Analysis of Variance (ANOVA) with post-hoc Scheffé and partial eta-squared (ƞP²), Kruskal–Wallis, Mann–Whitney U and Chi2 tests (p < 0.05). The CAD/CAM material showed an impact on the BS while the cleaning protocol did not affect the results. Zirconia obtained the highest BS, followed by lithium-disilicate-ceramic. Resin composite resulted in the overall lowest BS. For most fracture patterns, the cohesive type occurred. All tested cleaning protocols resulted in same BS values within one CAD/CAM material indicating that the impact of the cleaning method for the restorative material seems to play a subordinate role in obtaining durable bond strength to resin composite cement. Further, it indicates that the recommended bonding protocols are well adjusted to the respective materials and might be able to compensate the impact of not accurately performed cleaning protocols.