Viviana Rincon Montes

Dr. Viviana Rincon Montes


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2024 in Advanced Science
Verified
Journal Article
Open access
JSJ. Abu Shihada
J. Abu Shihada
MJM. Jung
M. Jung
SDS. Decke
S. Decke
LKL. Koschinski
L. Koschinski
SMS. Musall
S. Musall
AOAndreas Offenhäusser
Andreas Offenhäusser
Planar microelectrode arrays (MEAs) for – in vitro or in vivo – neuronal signal recordings lack the spatial resolution and sufficient signal‐to‐noise ratio (SNR) required for a detailed understanding of neural network function and synaptic plasticity. To overcome these limitations, a highly customizable three‐dimensional (3D) printing process is used in combination with thin film technology and a self‐aligned template‐assisted electrochemical deposition process to fabricate 3D‐printed‐based MEAs on stiff or flexible substrates. Devices with design flexibility and physical robustness are shown for recording neural activity in different in vitro and in vivo applications, achieving high‐aspect ratio 3D microelectrodes of up to 33:1. Here, MEAs successfully record neural activity in 3D neuronal cultures, retinal explants, and the cortex of living mice, thereby demonstrating the versatility of the 3D MEA while maintaining high‐quality neural recordings. Customizable 3D MEAs provide unique opportunities to study neural activity under regular or various pathological conditions, both in vitro and in vivo, and contribute to the development of drug screening and neuromodulation systems that can accurately monitor the activity of large neural networks over time.

30 April 2019 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
VMViviana Rincon Montes
Viviana Rincon Montes
JGJana Gehlen
Jana Gehlen
SLStefan Lück
Stefan Lück
WMWilfried Mokwa
Wilfried Mokwa
FMFrank Müller
Frank Müller
AOAndreas Offenhäusser
Andreas Offenhäusser
Background: Significant progress toward the recovery of useful vision in blind patients with severe degenerative retinal diseases caused by photoreceptor death has been achieved with the development of visual prostheses that stimulate the retina electrically. However, currently used prostheses do not provide feedback about the retinal activity before and upon stimulation and do not adjust to changes during the remodeling processes in the retina. Both features are desirable to improve the efficiency of the electrical stimulation (ES) therapy offered by these devices. Accordingly, devices that not only enable ES but at the same time provide information about the retinal activity are beneficial. Given the above, a bidirectional communication strategy, in which inner retinal cells are stimulated and the output neurons of the retina, the ganglion cells, are recorded using penetrating microelectrode arrays (MEAs) is proposed. Methods: Custom-made penetrating MEAs with four silicon-based shanks, each one with three or four iridium oxide electrodes specifically designed to match retinal dimensions were used to record the activity of light-adapted wildtype mice retinas and degenerated retinas from rd10 mice in vitro. In addition, responses to high potassium concentration and to light stimulation in wildtype retinas were examined. Furthermore, voltage-controlled ES was performed. Results: The spiking activity of retinal ganglion cells (RGCs) was recorded at different depths of penetration inside the retina. Physiological responses during an increase of the extracellular potassium concentration and phasic and tonic responses during light stimulation were captured. Moreover, pathologic rhythmic activity was recorded from degenerated retinas. Finally, ES of the inner retina and simultaneous recording of the activity of RGCs was accomplished. Conclusion: The access to different layers of the retina with penetrating electrodes while recording at the same time the spiking activity of RGCs broadens the use and the field of action of multi-shank and multi-site penetrating MEAs for retinal applications. It enables a bidirectional strategy to stimulate inner retinal cells electrically and to record from the spiking RGCs simultaneously (BiMEA). This opens the possibility of a feedback loop system to acknowledge the success of ES carried out by retinal prostheses.

10 April 2019 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
Dmitry KireevDmitry Kireev
Dmitry Kireev
VMViviana Rincon Montes
Viviana Rincon Montes
JSJelena Stevanovic
Jelena Stevanovic
KSKagithiri Srikantharajah
Kagithiri Srikantharajah
AOAndreas Offenhäusser
Andreas Offenhäusser
In the current work, we introduce a brand new line of versatile, flexible, and multifunctional MEA probes, the so-called Nano Neuro Net, or N3-MEAs. Material choice, dimensions, and room for further upgrade, were carefully considered when designing such probes in order to cover the widest application range possible. Proof of the operation principle of these novel probes is shown in the manuscript via the recording of extracellular signals, such as action potentials and local field potentials from cardiac cells and retinal ganglion cells of the heart tissue and eye respectively. Reasonably large signal to noise ratio (SNR) combined with effortless operation of the devices, mechanical and chemical stability, multifunctionality provide, in our opinion, an unprecedented blend. We show successful recordings of (1) action potentials from heart tissue with a SNR up to 13.2; (2) spontaneous activity of retinal ganglion cells with a SNR up to 12.8; and (3) local field potentials with an ERG-like waveform, as well as spiking responses of the retina to light stimulation. The results reveal not only the multi-functionality of these N3-MEAs, but high quality recordings of electrogenic tissues.

14 April 2025 in Advanced Materials
Verified
Journal Article
Open access
MJMarie Jung
Marie Jung
JSJamal Abu Shihada
Jamal Abu Shihada
SDSimon Decke
Simon Decke
LKLina Koschinski
Lina Koschinski
PGPeter Severin Graff
Peter Severin Graff
VMViviana Rincon Montes
Viviana Rincon Montes
3D microelectrode arrays (MEAs) are gaining popularity as brain–machine interfaces and platforms for studying electrophysiological activity. Interactions with neural tissue depend on the electrochemical, mechanical, and spatial features of the recording platform. While planar or protruding 2D MEAs are limited in their ability to capture neural activity across layers, existing 3D platforms still require advancements in manufacturing scalability, spatial resolution, and tissue integration. In this work, a customizable, scalable, and straightforward approach to fabricate flexible 3D kirigami MEAs containing both surface and penetrating electrodes, designed to interact with the 3D space of neural tissue, is presented. These novel probes feature up to 512 electrodes distributed across 128 shanks in a single flexible device, with shank heights reaching up to 1 mm. The 3D kirigami MEAs are successfully deployed in several neural applications, both in vitro and in vivo, and identified spatially dependent electrophysiological activity patterns. Flexible 3D kirigami MEAs are therefore a powerful tool for large‐scale electrical sampling of complex neural tissues while improving tissue integration and offering enhanced capabilities for analyzing neural disorders and disease models where high spatial resolution is required.

17 August 2023 in Journal of Materials Chemistry B
Verified
Journal Article
Open access
PDF file
LKLina Koschinski
Lina Koschinski
BLBohdan Lenyk
Bohdan Lenyk
MJMarie Jung
Marie Jung
ILIrene Lenzi
Irene Lenzi
BKBjörn Kampa
Björn Kampa
VMViviana Rincon Montes
Viviana Rincon Montes
We developed and compared transparent micro electrocorticography arrays (μECoGs) to combine electrophysiology and functional imaging. PEDOT:PSS-based μECoGs had the best trade-off of material and physical properties for chronic in vivo experiments.

4 November 2025 in Journal of Materials Chemistry C
Verified
Journal Article
Open access
PDF file
MKMartin Kasavetov
Martin Kasavetov
RSRuben Ruiz-Mateos Serrano
Ruben Ruiz-Mateos Serrano
ADAntonio Dominguez-Alfaro
Antonio Dominguez-Alfaro
CLChaeyeon Lee
Chaeyeon Lee
Matias PicchioMatias Picchio
Matias Picchio
AGAmparo Güemes
Amparo Güemes
Deep eutectic solvent–modified PEDOT:PSS enables single-layer thick, soft, and conductive coatings, enhancing charge transfer and neural interfacing, validated in vitro and in vivo in rat sciatic nerves. Original photograph, cartoon style applied with AI.