Jorge Ojeda-Castaneda

Prof. Dr. Jorge Ojeda-Castaneda

orcid

Research Focus & Metrics

Academic Career Length

41Years (1986-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2004 in Applied Optics
Verified
Journal Article
Closed access
PDF file
ACAlbertina Castro
Albertina Castro
JOJorge Ojeda-Castaneda
Jorge Ojeda-Castaneda
We present a family of asymmetric phase masks that extends the depth of field of an optical system. To verify our proposal, we compute several modulation transfer functions with focus errors, and we report numerical simulations of the images that can be achieved by use of our proposed procedure.

15 March 2004 in Optics Letters
Verified
Journal Article
Closed access
PDF file
ASAngel Sauceda
Angel Sauceda
JOJorge Ojeda-Castaneda
Jorge Ojeda-Castaneda
We explore the use of phase profiles with fractional power for tailoring modulation transfer functions with high focal depth at high pupil apertures. We present numerical simulations of the images that can be obtained with certain fractional-power profiles.

1 March 1990 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JOJorge Ojeda-Castaneda
Jorge Ojeda-Castaneda
LBL. R. Berriel-Valdos
L. R. Berriel-Valdos
We show that a zone plate with a prespecified number of foci, which are separated axially by Rayleigh’s limit of resolution, can create an arbitrarily high focal depth when used as an apodizer over an otherwise clear aperture. We discuss the resolution and light gathering power of this method.

1 July 1989 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JOJorge Ojeda-Castaneda
Jorge Ojeda-Castaneda
ETE. Tepichin
E. Tepichin
ADA. Diaz
A. Diaz
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

15 June 1988 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JOJorge Ojeda-Castaneda
Jorge Ojeda-Castaneda
RRR. Ramos
R. Ramos
ANA. Noyola-Isgleas
A. Noyola-Isgleas
We show that by using an iterative, digital restoration algorithm (Wiener or Kalman), it is possible to improve substantially the defocused optical transfer function of a previously apodized optical system. Consequently, high focal depth can be achieved by the use of an apodizer at the recording step, and a posteriori step of digital restoration. Computer-simulated images exhibit the focal depth achieved.

10 December 2015 in Advances in Optics and Photonics
Verified
Journal Article
Closed access
PDF file
JOJorge Ojeda-Castaneda
Jorge Ojeda-Castaneda
CGCristina M. Gómez-Sarabia
Cristina M. Gómez-Sarabia
We present a simple comprehensive treatment on the use of free-form optical elements, and of nonuniform optical windows, either for increasing focal depth [by regulating the width of the axial point spread function (PSF)] or for tuning the depth of field [by controlling the influence of focus error on the modulation transfer function (MTF)]. We employ the rising notation of pupil engineering, which incorporates techniques for controlling the spread of the axial PSF, as well as methods for governing the impact of focus errors on the MTF. Our discussion also includes the use of vortex lenses for designing nonconventional optical systems.