Yi Dai

Dr. Yi Dai

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
CGCong Gao
Cong Gao
SWShuo Wang
Shuo Wang
BLBaojie Liu
Baojie Liu
SYShuangquan Yao
Shuangquan Yao
YDYi Dai
Yi Dai
Pedram FatehiPedram Fatehi
Pedram Fatehi
In this study, we incorporated 2,3-dialdehyde nanocrystalline cellulose (DANC) into chitosan as a reinforcing agent and manufactured biodegradable films with enhanced gas barrier properties. DANC generated via periodate oxidation of cellulose nanocrystal (CNC) was blended at various concentrations with chitosan, and bionanocomposite films were prepared via casting and characterized systematically. The results showed that DANC developed Schiff based bond with chitosan that improved its properties significantly. The addition of DANC dramatically improved the gas barrier performance of the composite film, with water vapor permeability (WVP) value decreasing from 62.94 g·mm·m−2·atm−1·day−1 to 27.97 g·mm·m−2·atm−1·day−1 and oxygen permeability (OP) value decreasing from 0.14 cm3·mm·m−2·day−1·atm−1 to 0.026 cm3·mm·m−2·day−1·atm−1. Meanwhile, the maximum decomposition temperature (Tdmax) of the film increased from 286 °C to 354 °C, and the tensile strength of the film was increased from 23.60 MPa to 41.12 MPa when incorporating 25 wt.% of DANC. In addition, the chitosan/DANC (75/25, wt/wt) films exhibited superior thermal stability, gas barrier, and mechanical strength compared to the chitosan/CNC (75/25, wt/wt) film. These results confirm that the DANC and chitosan induced films with improved gas barrier, mechanical, and thermal properties for possible use in film packaging.

22 September 2023 in Journal of Chromatography A
Verified
Journal Article
Closed access
YDYi Dai
Yi Dai
KYKang Yu
Kang Yu
HZHong-Yue Zhu
Hong-Yue Zhu
HLHuan Li
Huan Li
JXJiao Xie
Jiao Xie
YXYue-Ming Xu
Yue-Ming Xu

25 July 2022 in Polymers
Verified
Journal Article
Open access
PDF file
XLXueyan Liu
Xueyan Liu
CZChuxing Zhu
Chuxing Zhu
KYKang Yu
Kang Yu
WLWei Li
Wei Li
YLYingchun Luo
Yingchun Luo
HWHao Wang
Hao Wang
This study demonstrates an accurate method for determining the moisture content in flavor microcapsules using headspace gas chromatography. The method involves measuring the gas chromatography signals of water from vapor in a headspace vial containing flavor microcapsules at a temperature of 125 °C. The measurements were recorded over four headspace extractions, from which the moisture content in the microcapsule samples was extrapolated via simple vapor-phase calibration. The results revealed that the proposed method demonstrated good precision (a relative standard deviation of <3.11%) and accuracy. The proposed method is accurate, highly sensitive, automated, and suitable for testing the moisture content of flavor microcapsules and related products.

22 August 2024 in Journal of Chromatography A
Verified
Journal Article
Closed access
HZHongyue Zhu
Hongyue Zhu
QHQiyu He
Qiyu He
TZTinghui Zhang
Tinghui Zhang
HWHao Wang
Hao Wang
HLHuan Li
Huan Li
YDYi Dai
Yi Dai

21 October 2022 in Analytical Letters
Verified
Journal Article
Closed access
WLWei Li
Wei Li
XLXue-Yan Liu
Xue-Yan Liu
KYKang Yu
Kang Yu
YLYing-Chun Luo
Ying-Chun Luo
DNDeng-Pan Nie
Deng-Pan Nie
HWHao Wang
Hao Wang
Total vaporization (TV) headspace (HS) gas chromatography (GC) is reported for the determination of ethanol in flavor oil microcapsules. Fifteen microliters of sample were placed in a headspace sample vial and a near-complete mass transfer of ethanol from the liquid phase to the vapor phase was obtained within one minute at 105 °C. This approach allowed the determination of ethanol in the sample by gas chromatography. Under the optimal conditions, the performance of this method was investigated, showing good linearity and a low limit of quantification equal to 8.95 mg/L. The relative standard deviation was less than 3.3%, and the recovery ranged from 95.4% to 101.3%. The method was efficient, accurate, and suitable for the quality control determination of ethanol in oil phase systems.

23 December 2024 in Journal of Chromatography A
Verified
Journal Article
Closed access
HZHongyue Zhu
Hongyue Zhu
HZHan Zheng
Han Zheng
TZTinghui Zhang
Tinghui Zhang
QHQiyu He
Qiyu He
HLHuan Li
Huan Li
YDYi Dai
Yi Dai