Asmir Avdicevic

Dr. Asmir Avdicevic

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2022 in Cancers
Verified
Journal Article
Open access
PDF file
HKHrvoje Kaučić
Hrvoje Kaučić
DKDomagoj Kosmina
Domagoj Kosmina
DSDragan Schwarz
Dragan Schwarz
AMAndreas Mack
Andreas Mack
HSHrvoje Sobat
Hrvoje Sobat
MMMihaela Mlinaric
Mihaela Mlinaric
(1) Background: The aim of this study was to evaluate the efficacy and safety of SABR for LAPC using Calypso® Extracranial Tracking for intrafractional, fiducial-based motion management, to present this motion management technique, as there are yet no published data on usage of Calypso® during SABR for LAPC, and to report on our clinical outcomes. (2) Methods: Fifty-four patients were treated with SABR in one, three, or five fractions, receiving median BED10 = 112.5 Gy. Thirty-eight patients received systemic treatment. End points were OS, FFLP, PFS, and toxicity. Actuarial survival analysis and univariate analysis were investigated. (3) Results: Median follow-up was 20 months. Median OS was 24 months. One-year FFLP and one-year OS were 100% and 90.7%, respectively. Median PFS was 18 months, and one-year PFS was 72.2%. Twenty-five patients (46.3%) were alive at the time of analysis, and both median FU and OS for this subgroup were 26 months. No acute/late toxicity > G2 was reported. (4) Conclusions: SABR for LAPC using Calypso® presented as an effective and safe treatment and could be a promising local therapeutic option with very acceptable toxicity, either as a single treatment or in a multimodality regimen. Dose escalation to the tumor combined with systemic treatment could yield better clinical outcomes.

1 July 2022 in Cancer Management and Research
Verified
Journal Article
Open access
PDF file
HKHrvoje Kaučić
Hrvoje Kaučić
DKDomagoj Kosmina
Domagoj Kosmina
DSDragan Schwarz
Dragan Schwarz
AMAndreas Mack
Andreas Mack
ACAdlan Cehobasic
Adlan Cehobasic
MBMarija Banović
Marija Banović
Purpose: To assess the efficacy and safety of stereotactic body radiotherapy for patients with unresectable, locally advanced pancreatic cancer using Optical Surface Management System – AlignRT (OSMS-AlignRT) as an optical body surface motion management in deep breath hold. Patients and Methods: Forty-five patients diagnosed with locally advanced pancreatic cancer were treated with stereotactic body radiotherapy in 3 or 5 fractions, and received varying BED10 (median 79.5 Gy) from April 2017 to December 2020. All patients were treated in deep breath hold with OSMS-AlignRT used as optical body surface motion management. Thirty-three patients received systemic treatment before and/or after stereotactic body radiotherapy, and twelve patients received no systemic treatment. In this retrospective, observational, single-arm study, primary endpoints were overall survival and freedom from local progression (ie, local control). Secondary endpoints were progression-free survival and toxicity. Actuarial survival analysis and univariate analysis were investigated. Results: Data from forty-five patients were analyzed. Median follow-up was 15 months. One-year freedom from local progression and survival were 95.5% and 71.1%, respectively. Median progression-free survival was 14 months. Median overall survival from diagnosis for all patients was 17 months, and 19 months for patients alive at the time of analysis. No patient had >G2 toxicity. Conclusion: Stereotactic body radiotherapy for locally advanced pancreatic cancer using OSMS-AlignRT as optical body surface motion management in deep breath hold patients is an effective and safe local treatment option, with no >G2 toxicity, and could be a promising therapeutic option with acceptable toxicity, either as a single treatment or in a multimodal regimen. OSMS-AlignRT provided accurate and reliable body surface motion management during stereotactic body radiotherapy.

1 December 2024 in Current Oncology
Verified
Journal Article
Open access
PDF file
VLVanda Leipold
Vanda Leipold
BJBlanka Jakšić
Blanka Jakšić
AAAsmir Avdicevic
Asmir Avdicevic
DKDomagoj Kosmina
Domagoj Kosmina
HKHrvoje Kaučić
Hrvoje Kaučić
DSDragan Schwarz
Dragan Schwarz
We present a patient treated with personalized ultra-fractionated stereotactic adaptive radiotherapy (PULSAR) for non-small cell lung cancer (NSCLC) using the adaptive Varian Ethos™ system equipped with the novel HyperSight imaging platform. Three pulses of 12 Gy were separated by a pause of four weeks during which the tumor was given enough time to respond to treatment. Only initial planning computed tomography (CT) was acquired on a CT simulator (Siemens Somatom Definition Edge), whereas other pulses were adapted using online cone beam computed tomography (CBCT) images (iCBCT Acuros reconstruction) acquired while the patient was lying on the treatment couch and delivered immediately. Significant tumor reduction was achieved between pulses, resulting in improved organs-at-risk sparing. In addition, the on-couch plan optimization based on CBCT greatly reduced the patient’s stay at the clinic and the duration of treatment preparation.

23 September 2025 in Cancers
Verified
Journal Article
Open access
PDF file
HKHrvoje Kaučić
Hrvoje Kaučić
MIMaja Karaman Ilic
Maja Karaman Ilic
DKDomagoj Kosmina
Domagoj Kosmina
AKAna Mišir Krpan
Ana Mišir Krpan
SDSunčana Divošević
Sunčana Divošević
DSDragan Schwarz
Dragan Schwarz
Background: The aim of this retrospective, single-arm study was to present the technique and preliminary efficacy and safety results of a single-fraction SBRT for LAPC using total intravenous anaesthesia and optical surface guidance as motion management. Methods: Fifty-five patients with locally advanced pancreatic cancer were treated with SBRT with a single-fraction receiving a median BED10 = 128.9 Gy. Forty-two patients received systemic treatment. End points were OS, FFLP, PFS, and toxicity. Actuarial survival analysis and univariate analysis were investigated. Results: The median follow-up was 15 months, mean OS was 18 months (95% CI: 16.7 to 19.3), and the one-year FFLP and 1-year OS were 100% and 90.9% (95% CI: ± 1.5%), respectively. Median PFS was 12 months (95% CI: 9.5 to 14.4), and 1-year PFS was 85.5% (95% CI: ± 1.4%). Thirty-five patients (63.6%) were alive at the time of analysis. No acute/late toxicity > G2/G1 was reported. Conclusions: SBRT for LAPC using total intravenous anaesthesia and optical surface guidance presented as an effective and safe treatment with very low toxicity.

1 September 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
HKHrvoje Kaučić
Hrvoje Kaučić
MIMaja Karaman Ilic
Maja Karaman Ilic
DKDomagoj Kosmina
Domagoj Kosmina
AKAna Mišir Krpan
Ana Mišir Krpan
SDSunčana Divošević
Sunčana Divošević
DSDragan Schwarz
Dragan Schwarz
Background: The aim of this study was to present the technique and preliminary results of efficacy and safety for single-fraction SBRT for LAPC using Total Intravenous Anaesthesia and Optical Surface Guidance as motion management. Methods: Fifty-five patients were treated with SBRT in a single-fraction receiving median BED10 = 128.9 Gy. Forty-two patients received systemic treatment. End points were OS, FFLP, PFS, and toxicity. Actuarial survival analysis and univariate analysis were investigated. Results: Median follow-up was 15 months. Mean OS was 26.7 months. One-year FFLP and 1-year OS were 100% and 90.9%, respectively. Median PFS was 18 months, and 1-year PFS was 85.5%. Thirty-five patients (63.6%) were alive at the time of analysis. No acute/late toxicity > G2/G1 was reported. Conclusions: SBRT for LAPC using Total Intravenous Anaesthesia and Optical Surface Guidance presented as an effective and safe treatment with very low toxicity.