Do Haeng Hur

Dr. Do Haeng Hur

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2016 in Coatings
Verified
Journal Article
Open access
PDF file
Soon-Hyeok JeonSoon-Hyeok Jeon
Soon-Hyeok Jeon
WCWon-Ik Choi
Won-Ik Choi
GSGeun Dong Song
Geun Dong Song
YSYeong-Ho Son
Yeong-Ho Son
DHDo Haeng Hur
Do Haeng Hur
In this work, we investigated the effects of surface roughness and agitation on the morphology of magnetite films electrodeposited from alkaline Fe(III)-triethanolamine (TEA) solutions on carbon steel substrates. The surface roughness of the carbon steel substrates was maintained in the range of 1.64–0.06 μm by using mechanical grinding and polishing methods. The agitation speed was set at 0 and 900 rpm during the electrodeposition process. The particle size and surface roughness value of the magnetite films gradually decreased with decreasing substrate roughness. However, the influence of the substrate roughness on the thickness of the magnetite film was negligible. The morphology of the magnetite film fabricated at 900 rpm appeared to be highly faceted compared to that of the magnetite film produced at 0 rpm. The thickness and surface roughness of the magnetite film significantly increased with the agitation speed, which also significantly affected the electrodeposition efficiency. The effects of substrate surface roughness and agitation on the morphology of magnetite films electrodeposited on carbon steel substrates were also discussed. The obtained results provide critical information for the simulation of magnetite deposits on carbon steel pipes in the secondary systems of nuclear power plants.

9 September 2020 in Materials
Verified
Journal Article
Open access
PDF file
Ji-Min LeeJi-Min Lee
Ji-Min Lee
DLDong-Seok Lim
Dong-Seok Lim
Soon-Hyeok JeonSoon-Hyeok Jeon
Soon-Hyeok Jeon
DHDo Haeng Hur
Do Haeng Hur
Magnetite particles deposited on the secondary side of a steam generator (SG) can degrade the integrity and performance of pressurized water reactors. Therefore, it is necessary to produce the data of fundamental interfacial electrokinetic properties of magnetite particles and SG tube materials. This study investigated the zeta potentials of magnetite nanoparticles and Alloy 690 surfaces, which were dependent on the pH value, pH agent, and the presence of NaCl. The zeta potentials of the magnetite nanoparticles increased in the negative direction as the pH increased, regardless of the pH agent. At the same pH value, the absolute values of the zeta potentials with different pH agents were: ethanolamine < ammonia < morpholine. In the presence of NaCl, the zeta potentials of the particles further increased negatively. The meaning of the measured zeta potentials was discussed in terms of the dispersion stability and the agglomeration of the particles. Based on the relationship between the zeta potentials of the particles and Alloy 690 surfaces, the magnetite deposition on Alloy 690 was also discussed. Furthermore, the empirical formulas for the pH-dependent zeta potentials of magnetite particles in each alkaline solution were suggested.

1 November 2022 in Journal of Materials Research and Technology
Verified
Journal Article
Open access
DHDo Haeng Hur
Do Haeng Hur
SJSoon-Hyeok Jeon
Soon-Hyeok Jeon
JHjeoh Han
jeoh Han
SPSun-Young Park
Sun-Young Park
YCYoung-Bum Chun
Young-Bum Chun

1 January 2016 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
SJSoon-Hyeok Jeon
Soon-Hyeok Jeon
GSGeun Dong Song
Geun Dong Song
DHDo Haeng Hur
Do Haeng Hur
The purpose of this work is to investigate the effect of electrochemical deposition potential on the morphology and structure of iron-based films on the carbon steel in an alkaline Fe(III)-triethanolamine solution. The deposition potentials were controlled in the range from −1.05 to −1.23 VSCEfor 1800 s at 80°C. Total amount of electric charge for electrodeposition process was increased with increasing deposition potential in negative direction. Pure magnetite films with a columnar and defect-free structure were deposited in the potential range from −1.05 VSCEto −1.11 VSCE. However, petal-like magnetite film containing ferrihydrite and iron was formed at −1.17 VSCE. At more negative potential of −1.23 VSCE, two distinct layers were observed: a porous outer layer containing ferrihydrite and goethite and a compact inner layer consisting of columnar metallic iron. In the potential range from −1.05 to −1.11 VSCE, the pure magnetite films gradually increased the thickness and decreased the surface roughness with an increase of the overpotential. The magnetite film deposited at −1.11 VSCEshowed the most thick layer and smooth surface state.

2 November 2018 in Metals
Verified
Journal Article
Open access
PDF file
Soon-Hyeok JeonSoon-Hyeok Jeon
Soon-Hyeok Jeon
GSGeun Dong Song
Geun Dong Song
DHDo Haeng Hur
Do Haeng Hur
In secondary coolant system of the pressurized water reactors, the reduced corrosion products such as metallic Cu and Pb particles were accumulated in the pores of the magnetite flakes and electrically contacted to the steam generator materials. The micro-galvanic corrosion behavior of steam generator materials (steam generator tube materials: Alloy 600 and Alloy 690, steam generator tube sheet materials: SA508 Gr.3) contacted to the corrosion products (magnetite, Cu, and Pb) was investigated in an alkaline solution. The steam generator materials considered in this study were all the anodic elements of the galvanic pair because their corrosion potentials were lower than those of the corrosion products. The corrosion rate of the steam generator materials was increased by the galvanic coupling with the each corrosion products, and was more accelerated with increasing the area ratio of the corrosion products to the steam generator materials. Among the corrosion products, Cu has the largest galvanic effect on steam generator materials in the pores when area ratio of cathode to anode is 10.

2 January 2018 in Materials
Verified
Journal Article
Open access
PDF file
Soon-Hyeok JeonSoon-Hyeok Jeon
Soon-Hyeok Jeon
YSYeong-Ho Son
Yeong-Ho Son
WCWon-Ik Choi
Won-Ik Choi
GSGeun Dong Song
Geun Dong Song
DHDo Haeng Hur
Do Haeng Hur
In nuclear power plants, the main corrosion product that is deposited on the outside of steam generator tubes is porous magnetite. The objective of this study was to simulate porous magnetite that is deposited on thermally treated (TT) Alloy 690 steam generator tubes. A magnetite layer was electrodeposited on an Alloy 690TT substrate in an Fe(III)-triethanolamine solution. After electrodeposition, the dense magnetite layer was immersed to simulate porous magnetite deposits in alkaline solution for 50 days at room temperature. The dense morphology of the magnetite layer was changed to a porous structure by reductive dissolution reaction. The simulated porous magnetite layer was compared with flakes of steam generator tubes, which were collected from the secondary water system of a real nuclear power plant during sludge lancing. Possible nuclear research applications using simulated porous magnetite specimens are also proposed.