Numerous vital signs are reported in association with stress response assessment, but their application varies widely. This work provides an overview over methods for stress induction and strain assessment, and presents a multimodal experimental study to identify the most important vital signs for effective assessment of the response to acute mental stress. We induced acute mental stress in 65 healthy participants with the Mannheim Multicomponent Stress Test and acquired self-assessment measures (Likert scale, Self-Assessment Manikin), salivary α-amylase and cortisol concentrations as well as 60 vital signs from biosignals, such as heart rate variability parameters, QT variability parameters, skin conductance level, and breath rate. By means of statistical testing and a self-optimizing logistic regression, we identified the most important biosignal vital signs. Fifteen biosignal vital signs related to ventricular repolarization variability, blood pressure, skin conductance, and respiration showed significant results. The logistic regression converged with QT variability index, left ventricular work index, earlobe pulse arrival time, skin conductance level, rise time and number of skin conductance responses, breath rate, and breath rate variability (F1 = 0.82). Self-assessment measures indicated successful stress induction. α-amylase and cortisol showed effect sizes of -0.78 and 0.55, respectively. In summary, the hypothalamic-pituitary-adrenocortical axis and sympathetic nervous system were successfully activated. Our findings facilitate a coherent and integrative understanding of the assessment of the stress response and help to align applications and future research concerning acute mental stress.
1 July 2021 in Biomedical Signal Processing and Control
To prevent further brain tumour growth, malignant tissue should be removed as completely as possible in neurosurgical operations. Therefore, differentiation between tumour and brain tissue as well as detecting functional areas is very important. Hyperspectral imaging (HSI) can be used to get spatial information about brain tissue types and characteristics in a quasi-continuous reflection spectrum. In this paper, workflow and some aspects of an adapted hardware system for intraoperative hyperspectral data acquisition in neurosurgery are discussed. By comparing an intraoperative with a laboratory setup, the influences of the surgical microscope are made visible through the differences in illumination and a pixel- and wavelength-specific signal-to-noise ratio (SNR) calculation. Due to the significant differences in shape and wavelength-dependent intensity of light sources, it can be shown which kind of illumination is most suitable for the setups. Spectra between 550 and 1,000 nm are characterized of at least 40 dB SNR in laboratory and 25 dB in intraoperative setup in an area of the image relevant for evaluation. A first validation of the intraoperative hyperspectral imaging hardware setup shows that all system parts and intraoperatively recorded data can be evaluated. Exemplarily, a classification map was generated that allows visualization of measured properties of raw data. The results reveal that it is possible and beneficial to use HSI for wavelength-related intraoperative data acquisition in neurosurgery. There are still technical facts to optimize for raw data detection prior to adapting image processing algorithms to specify tissue quality and function.
Objective . After skin flap transplants, perfusion strength monitoring is essential for the early detection of tissue perfusion disorders and thus to ensure the survival of skin flaps. Camera-based photoplethysmography (cbPPG) is a non-contact measurement method, using video cameras and ambient light, which provides spatially resolved information about tissue perfusion. It has not been researched yet whether the measurement depth of cbPPG, which is limited by the penetration depth of ambient light, is sufficient to reach pulsatile vessels and thus to measure the perfusion strength in regions that are relevant for skin flap transplants. Approach . We applied constant negative pressure (compared to ambient pressure) to the anterior thighs of 40 healthy subjects. Seven measurements (two before and five up to 90 min after the intervention) were acquired using an RGB video camera and photospectrometry simultaneously. We investigated the performance of different algorithmic approaches for perfusion strength assessment, including the signal-to-noise ratio (SNR), its logarithmic components logS and logN, amplitude maps, and the amplitude height of alternating and direct signal components. Main results . We found strong correlations of up to r = 0.694 ( p < 0.001) between photospectrometric measurements and all cbPPG parameters except SNR when using the green color channel. The transfer of cbPPG signals to POS, CHROM, and O3C did not lead to systematic improvements. However, for direct signal components, the transformation to O3C led to correlations of up to r = 0.744 ( p < 0.001) with photospectrometric measurements. Significance . Our results indicate that a camera-based perfusion strength assessment in tissue with deep-seated pulsatile vessels is possible.
1 October 2021 in Current Directions in Biomedical Engineering
Mental stress triggers positive inotropic and chronotropic effects as well as peripheral vasoconstriction. This alters the pulse arrival time (PAT), the duration between electrical excitation of the ventricles and arrival of the pulse wave in the periphery. We conducted a study to examine PAT during five rest blocks and under mental stress utilizing the Mannheim Multicomponent Stress Test. Electrocardiograms as well as finger and earlobe photoplethysmograms were recorded. PAT was calculated for over 135,000 heartbeats from 42 healthy volunteers as the time duration between the R peak in the electrocardiogram and the following pulse onset in the respective photoplethysmogram. To identify the effect of mental stress, block-wise PAT means were statistically analyzed with repeated measures ANOVA. The analyses showed significant differences between the block means for both PAT measures (p < 0.001). Post-hoc tests revealed significantly reduced PAT during the stress block compared to all rest blocks for both PAT measures (p < 0.001). We found no significant differences between the rest blocks. Our results support that PAT is a sensitive vital parameter for the detection of mental stress in healthy volunteers. This holds true for both measurement positions, the finger and the earlobe.
Imaging photoplethysmography (iPPG) is a contactless approach for the extraction of the blood volume pulsation (BVP). Analyzing the small intensity changes resulting from fluctuations in light absorption in upper skin layers enables BVP extraction. Inhomogeneous illumination or head movements impede iPPG-based BVP extraction. To mitigate these influences, an important step is the accurate skin segmentation and weighting, which has received insufficient attention in state-of-the-art (SOTA) deep learning-based approaches in particular. Therefore, we propose DeepPerfusion, a two-branched deep learning architecture, that combines precise skin segmentation and weighting as well as BVP extraction into one model. Together with our newly developed patch-based temporal normalization mechanism and our innovative training pipeline, DeepPerfusion achieved highly accurate BVP extraction. We performed a thorough performance analysis and evaluated the mean absolute error (MAE) for heart rate extraction and the signal-to-noise ratio (SNR) on 156 subjects from three publicly available datasets and compared it with nine SOTA approaches that underwent the same training and evaluation pipeline. For the median across subjects of each dataset, DeepPerfusion consistently achieved MAE below 1 beat per minute, outperforming the best SOTA approaches by up to 49%. Furthermore, DeepPerfusion achieved high SNR with at least 5.81dB which was about two to three times higher compared to the best SOTA approaches. In contrast to SOTA approaches, DeepPerfusion's performance was consistent, robust and highly precise. This demonstrates DeepPerfusion's ability to perform high-precision BVP extraction. We expect this to open up new diagnostic applications for iPPG in the future.