Jaewook Kim

Dr. Jaewook Kim

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JKJaewook Kim
Jaewook Kim
YKyekwang kim
yekwang kim
KSKang Seonghyun
Kang Seonghyun
SKSeung-Jong Kim
Seung-Jong Kim
An FDA-approved soft wearable robot, the Myosuit, which was designed to provide hip and knee extension torque has recently been commercialized. While studies have reported reductions in metabolic costs, increased gait speeds, and improvements in clinical test scores, a comprehensive analysis of electromyography (EMG) signals and joint kinematics is warranted because the recruitment of appropriate muscle groups during physiological movement patterns facilitates effective motor learning. Here, we compared the lower limb joint kinematics and EMG patterns while wearing the Myosuit with that of unassisted conditions when performing level overground and incline treadmill gait. The level overground gait sessions (seven healthy subjects) were performed at self-selected speeds and the incline treadmill gait sessions (four healthy subjects) were performed at 2, 3, 4, and 5 km/h. In order to evaluate how the user is assisted, we conducted a biomechanical analysis according to the three major gait tasks: weight acceptance (WA), single-limb support, and limb advancement. The results from the gait sessions suggest that Myosuit not only well preserves the users’ natural patterns, but more importantly reduce knee extensor demand during the WA phase for both level and incline gait.

8 December 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JKJaewook Kim
Jaewook Kim
YKyekwang kim
yekwang kim
SKSeung-Jong Kim
Seung-Jong Kim
Current gait rehabilitation strategies rely heavily on motor learning principles, which involve facilitating active patient participation, high-doses of biomechanical task-related motor activities and accurate feedback. Furthermore, appropriate muscle groups need to be recruited for the joint movements that constitute the biomechanical task-related activities in order to effectively promote motor learning. Recently, exoskeleton-type robots utilizing crutches have been incorporated into overground gait rehabilitation programs. However, it is unclear which gait-related tasks are being trained because the joint movements and muscle recruitment patterns deviate from those of natural gait. This raises concerns because repetitive training with these devices may not lead to desirable rehabilitative gains. In this study, we compare the lower limb joint angles and electromyography patterns of healthy subjects walking with and without ReWalk in accordance with the three major biomechanical tasks required by bipedal gait: weight acceptance (WA), single-limb support, and limb advancement. Furthermore, we investigate whether the physical constraints of ReWalk, most noticeably the use of crutches and fixed ankle joints, were responsible for the specific changes by conducting additional walking sessions with either crutches or ankle foot orthoses. The results from the six healthy male volunteers suggest that the gait patterns observed with ReWalk deviate significantly from those of natural gait, particularly during the WA, and closely resemble those of crutch gait.

1 May 2020 in Electronics Letters
Verified
Journal Article
Open access
PDF file
JKJaewook Kim
Jaewook Kim
SCS.H. Chung
S.H. Chung
JCJ. Choi
J. Choi
JLJ.M. Lee
J.M. Lee
SKSeung-Jong Kim
Seung-Jong Kim
The lack of patient effort during robot‐assisted gait training (RAGT) is thought to be the main factor behind unsatisfactory rehabilitative efficacy among hemiparetic stroke patients. A key milestone to implement patient‐driven RAGT is to predict gait intent prior to actual joint movement. Here, the authors propose a method of predicting step speed intent via surface electromyogram (EMG) signals from the soleus. Six lower‐limb muscles were initially evaluated on a treadmill, and the results suggest that the soleus EMG signals correlate well with step speed. The authors further propose a simple linear regression model which predicts subsequent step speed via current soleus EMG signals with over‐ground gait sessions, of ∼0.6. The proposed experimental results and simple prediction model should be applicable for RAGT without significant modifications.

22 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
KSKang Seonghyun
Kang Seonghyun
JKJaewook Kim
Jaewook Kim
YKyekwang kim
yekwang kim
JMJuhui Moon
Juhui Moon
HKHaK-Jun Kim
HaK-Jun Kim
SKSeung-Jong Kim
Seung-Jong Kim
Chronic ankle instability (CAI), due to its chronic nature and biomechanical complexity, is well-suited for continuous monitoring and tele-rehabilitation using wearable sensor technology. This study assessed whether a smart insole system, equipped with 4 force-sensing resistor sensors and an inertial measurement unit, combined with functional tests and biomechanical indices, could distinguish CAI patients from healthy controls. A total of 21 CAI patients (23.8 ± 5.1 years) and 16 controls (22.62 ± 2.60 years) completed a battery of functional performance tests while wearing the smart insole system. The results showed an increased medial-lateral pressure ratio in the CAI during heel raise (p = 0.031, effect size = 0.82) and hop tests, suggesting an everted foot position. Significant deviations in center-of-pressure trajectory during double-leg heel raises (p = 0.005, effect size = 1.10) suggested asymmetric motion coordination, while compensatory fluctuations of the lifted limb during single-leg balance tests (p = 0.011, effect size = 1.03) were greater in CAI patients. These findings facilitated the development of features to characterize CAI-specific movement patterns. Together, this system shows promise as a quantitative assessment tool for CAI, supporting improved treatment outcomes through tele-rehabilitation.

JKJaewook Kim
Jaewook Kim
YKyekwang kim
yekwang kim
JMJuhui Moon
Juhui Moon
JKJoo Kong
Joo Kong
SKSeung-Jong Kim
Seung-Jong Kim
Basic human ambulation relies on a bipedal gait, which has been reported to be directly related to quality of life. However, injuries to the lower limb can cause an inability to walk and require non-weightbearing periods to heal. Among the many ambulatory aids, standard axillary crutches are prescribed. However, due to the disadvantages of having to use both hands, a slow gait, pain, nerve damage, and gait patterns that differ from that of healthy subjects, currently, a new generation of ambulatory aids has emerged. Among such aids, hands-free crutches (HFCs) are of particular interest due to their form factor, which does not require the use of the hands and facilitates a bipedal gait. In this study, we present an assessment of whether any different gait patterns, compared to overground gait, appeared on the unaffected limb during walking with an HFC. The spatiotemporal parameters, plantar force, lower-limb joint angles, and EMG patterns were evaluated. In conclusion, the results from 10 healthy subjects suggest that wearing an HFC causes only slight changes in the biomechanical gait patterns examined in the unaffected limb compared with overground walking without an HFC.

Verified
Journal Article
Open access
PDF file
JKJaewook Kim
Jaewook Kim
YKyekwang kim
yekwang kim
JMJuhui Moon
Juhui Moon
SKSeung-Jong Kim
Seung-Jong Kim
Post-stroke gait is characterized by slow and asymmetrical hemiparetic gait. This is attributed to the paretic lower limb which has limited plantar propulsion. The most effective method to restore paretic limb function is constraint-induced movement therapy (CIMT), which promotes the usage of the paretic limb by restricting the movement of the unafflicted limb. However, due to the necessity of both lower limbs to perform gait, CIMT methods could not be directly applied for gait rehabilitation. In this study, we explore the feasibility of utilizing a knee scooter as a means to facilitate CIMT gait training. We hypothesize that if lower limb kinematics and muscle activation patterns during gait with a knee scooter match that of natural gait, the knee scooter could be utilized for CIMT gait training. We measured the lower-limb joint angles, plantar force, EMG patterns, stride length, and step times of 13 healthy subjects during gait with a knee scooter and natural gait. The results suggest that the gait patterns while using the knee scooter closely resemble those of natural gait.