Danny Soares

Dr. Danny Soares

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2022 in Molecules
Verified
Journal Article
Open access
PDF file
DSDanny Soares
Danny Soares
Biocompatible hyaluronic acid (HA, hyaluronan) gel implants have altered the therapeutic landscape of surgery and medicine, fostering an array of innovative products that include viscosurgical aids, synovial supplements, and drug-eluting nanomaterials. However, it is perhaps the explosive growth in the cosmetic applications of injectable dermal fillers that has captured the brightest spotlight, emerging as the dominant modality in plastic surgery and aesthetic medicine. The popularity surge with which injectable HA fillers have risen to in vogue status has also brought a concomitant increase in the incidence of once-rare iatrogenic vaso-occlusive injuries ranging from disfiguring facial skin necrosis to disabling neuro-ophthalmological sequelae. As our understanding of the pathophysiology of these injuries has evolved, supplemented by more than a century of astute observations, the formulation of novel therapeutic and preventative strategies has permitted the amelioration of this burdensome complication. In this special issue article, we review the relevant mechanisms underlying HA filler-induced vascular occlusion (FIVO), with particular emphasis on the rheo-mechanical aspects of vascular blockade; the thromboembolic potential of HA mixtures; and the tissue-specific ischemic susceptibility of microvascular networks, which leads to underperfusion, hypoxia, and ultimate injury. In addition, recent therapeutic advances and novel considerations on the prevention and management of muco-cutaneous and neuro-ophthalmological complications are examined.

15 February 2024 in Journal of Cosmetic Dermatology
Verified
Journal Article
Open access
AMAlec D McCarthy
Alec D McCarthy
DSDanny Soares
Danny Soares
ACAkash Chandawarkar
Akash Chandawarkar
RERadia El‐Banna
Radia El‐Banna
NHNadine Hagedorn
Nadine Hagedorn
Background: Calcium hydroxylapatite‐carboxymethylcellulose (CaHA‐CMC) injectables have emerged as dual‐purpose fillers with bioregenerative and direct filling capabilities.Aims: This study investigates the rheological properties of CaHA‐CMC and its CMC carrier gel at various dilutions.Methods: The storage modulus (G′), loss modulus (G″), complex viscosity (η*), loss factor (tan δ), cohesivity, and extrusion force were evaluated for a range of CaHA‐CMC aqueous dilutions with an oscillatory rheometer, drop weight testing, and force analysis, respectively.Results: Results revealed a significant decrease in G′, η*, and increase in tan(δ) with increasing dilution, indicating a decline in the product's direct filling capabilities. Cohesivity decreased dramatically with dilution, potentially enhancing tissue biointegration and the product's biostimulatory effects. The CMC gel carrier displayed inelastic and non‐resilient properties, with rheological changes differing from CaHA‐CMC. Dilutional rheology was also correlated with previously published dilution‐dependent biostimulatory data where hyperdiluted CaHA‐CMC (>1:2) demonstrated a regenerative profile and diluted or hypodiluted mixtures retained meaningful filling properties and increased regeneration.Conclusions: These findings offer a continuum for tailoring the product's rheological profile to match specific tissue requirements. Customizable rheology allows CaHA‐CMC to be tuned for either filling and contouring or optimal regenerative effects. Importantly, safety implications related to vascular occlusion suggest that dilutional rheomodulation decreases the risk of vascular events. In conclusion, this study highlights the significant impact of aqueous dilution on the rheological properties of CaHA‐CMC and its carrier gel. The findings support the clinical application of tailored dilutions to achieve desired outcomes, providing versatility and safety for aesthetic applications.

11 August 2023 in Annals of Emergency Medicine
Verified
Journal Article
Closed access
DSDanny Soares
Danny Soares
SHStephanie D. Hynes
Stephanie D. Hynes
CYChristina H. Yi
Christina H. Yi
SSSabrina Shah-Desai
Sabrina Shah-Desai
SISteven C. Irving
Steven C. Irving

2 February 2025 in Journal of Colloid and Interface Science
Verified
Journal Article
Open access
PSPritha Sarkar
Pritha Sarkar
DSDanny Soares
Danny Soares
AMAlec D McCarthy
Alec D McCarthy
ALAlina Lee
Alina Lee
CCCavan Cohoes
Cavan Cohoes
Kausik MukhopadhyayKausik Mukhopadhyay
Kausik Mukhopadhyay
Therapeutic implantable hydrogels are increasingly utilized in medicine due to their versatile viscoelastic properties. Nonetheless, the clinical efficacy and longevity of these products is predicated on their ability to retain structural integrity post-implantation. Gel cohesion, defined as the capacity to resist fragmentation, has lacked empirical standardization, especially in high shear environments, with present methods often conflating this mechanical parameter with gel ductility or qualitative perceptions of tackiness. In this study, we introduce a novel quantitative method of cohesion analysis termed the Modulus of Cohesion (MOC). The MOC is derived from rheometric strain sweep testing by calculating the difference between the elastic and viscous moduli from 0% strain to the crossover point. This novel parameter provides a direct measure of mechanical energy storage and dissipation balance, accounting for linear and nonlinear deformation in shear strain. Eleven commercially available hyaluronic acid gels are evaluated using this method, alongside uniaxial tension and drop weight methods to establish correlations between MOC and existing cohesion metrics. Additionally, haptic sensory analysis and aqueous dispersion methods from previous reports are correlated with rheometric and mechanical tests. Our results demonstrate that MOC provides a reliable, reproducible measure of gel cohesiveness, correlating strongly with other quantitative methods with augmented precision.

12 August 2024 in Gels
Verified
Journal Article
Open access
PDF file
DSDanny Soares
Danny Soares
AMAlec D McCarthy
Alec D McCarthy
Accidental arterial embolization of hyaluronic acid (HA) fillers can lead to severe complications, including skin ischemia, blindness, and stroke. Currently, the intra-arterial dispersal and fragmentation behavior of HA gels is unknown but critical to our understanding of the pathomechanism of these injuries. This work introduces the Pulsatile Unit for the Laboratory Simulation of Arterio-embolic Restrictions (PULSAR) and evaluates the intravascular behavior of different HA gels. The fragmentation and dispersal behaviors of four HA gels with distinct rheological properties were evaluated via high-resolution videography and ImageJ particle size and morphology analysis. The gels’ elastic modulus (G′), loss modulus (G″), tan(δ), and HA concentration were subsequently correlated with their intra-arterial behaviors. This study effectively confirms the extensive fragmentation of HA gels upon arterial inoculation, with particle sizes ranging from 1 mm. Gel particle size and morphology correlated most significantly with tan(δ). Conversely, arterial flow rates did not significantly influence gel fragmentation behavior, though the probability of proximal, macrovascular obstruction was affected. Overall, this study validates the PULSAR model for simulation of arterial dynamics and the testing of intravascular filler kinematics. The findings demonstrate the ability of gels to microfragment and disseminate distally, as well as induce partial proximal occlusion depending on gel rheology and arterial flow parameters.

19 August 2022 in Plastic and Reconstructive Surgery - Global Open
Verified
Journal Article
Open access
DSDanny Soares
Danny Soares
HHHaley N. Pa-C von Haven
Haley N. Pa-C von Haven
CYChristina H. Yi
Christina H. Yi
Background: Photographs of cosmetic treatment outcomes on social media are prone to bias and misrepresentation from nonadherence to established photographic standards. However, there is currently insufficient information regarding which norms are most-commonly violated, precluding quality improvement efforts. Methods: A qualitative study of cosmetic treatment photographs published on Instagram was undertaken in accordance with the Guidelines for Reporting Reliability and Agreement Studies using a newly proposed Standards for the Evaluation of Photographs In Aesthetics (SEPIA) nine-point photograph scoring system and grading scale. Results: A total of 510 posts encompassing 2020 clinical photographs published by 102 practitioner accounts on Instagram were audited for photographic quality. The average score was 4 out of 9 (medium quality), with approximately 40% of posts scoring in the low-quality range. Zoom, lighting, timing, and presentation of multiple views were the standards most-commonly disregarded. Plastic and Reconstructive Surgery specialty and subspecialty (PRSS) practitioners scored higher (4.5/9 versus 3.1/9, P = 0.002) and had fewer low-quality posts (22% versus 54%, P = 0.001) than non-PRSS providers. Low-quality photographs were most often seen with rhinoplasty (30% versus 7%, P < 0.00001) and lip filler (60% versus 33%, P = 0.0001) compared with surgical and nonsurgical treatments, respectively, due to a higher incidence of immediate photographs and selfies. Conclusions: Before and after photographs of surgical and nonsurgical cosmetic treatment outcomes on social media are frequently of substandard quality. This study outlines specific items frequently neglected in outcomes photography to assist practitioners in maximizing adherence to established standards of photography online.