Buildings with large open spaces in which chemicals are handled are often exposed to the risk of explosions. Computational fluid dynamics is a useful and convenient way to investigate contaminant dispersion in such large spaces. The turbulent Schmidt number (Sct) concept has typically been used in this regard, and most studies have adopted a default value. We studied the concentration distribution for sulfur hexafluoride (SF6) assuming different emission rates and considering the effect of Sct. Then we examined the same problem for a light gas by assuming hydrogen gas (H2) as the contaminant. When SF6 was considered as the contaminant gas, a variation in the emission rate completely changed the concentration distribution. When the emission rate was low, the gravitational effect did not take place. For both low and high emission rates, an increase in Sct accelerated the transport rate of SF6. In contrast, for H2 as the contaminant gas, a larger Sct could induce a decrease in the H2 transport rate.
Four degraded products of limonoid, including three previously undescribed compounds (1, 3, 4), were isolated from the root bark of Dictamnus dasycarpus Turcz. Their structures were elucidated by extensively spectroscopic methods (NMR, MS, ECD, etc), as well as quantum chemical calculations. The broadening NMR lines, along with the relaxation time and DOSY experiment revealed the self-aggregation of 1 in chloroform through H-bond between -COOH and -OH, which provided additional evidence to distinguish acid and ester/lactone in structure elucidation. Compounds 1-3 attenuated oleic acid-induced lipid accumulation in HepG2 cells significantly, with inhibition rates of 19.8%, 23.6%, and 13.5% at 10 μM, much stronger than fenofibrate, affording a novel scaffold for drug discovery against fatty liver disease.
R290 as a refrigerant has significant advantages of low cost, high energy efficiency, and more environmental protection, but the leakage will form a hazardous area inside the indoor unit and the room where the concentration exceeds the lower flammable limit of propane. In this paper, we focus on the gas-liquid two-phase leakage of R-290 indoor air conditioner at the evaporator, and use Computational Fluid Dynamics (CFD) method to numerically simulate the refrigerant leakage dispersion at three air conditioning supply volumes of 178.2 m3/h, 342 m3/h and 576 m3/h, and analyze the indoor velocity distribution and concentration distribution. The results show that the trajectory of the refrigerant jet changes under different air supply volumes, and the simulation results show that the spatial extent of the combustion explosion limit is mainly distributed at the air conditioning leak and the air conditioning outlet. Vortices were formed in the local area above the propane leakage port and then spread.