Martin Andersen

Mr. Martin Andersen

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2022 in Energies
Verified
Journal Article
Open access
PDF file
MAMartin Andersen
Martin Andersen
CBChris Bales
Chris Bales
JDJan-Olof Dalenback
Jan-Olof Dalenback
One challenge in today’s district heating systems is the relatively high distribution heat loss. Lowering distribution temperatures is one way to reduce operational costs resulting from high heat losses, while changing the distribution system from steel pipes to plastic pipes and changing the heat distribution concept can reduce investment costs. The result is that the overall life cycle cost of the district heating system is reduced, leading to the improved cost competitiveness of district heating versus individual heating options. The main aim of this study was to determine the most cost-efficient distribution system for a theoretical solar district heating system, by comparing the marginal life cycle cost of two different distribution systems. A secondary aim was to determine the influence of the employed pipe type and insulation level on the marginal life cycle cost by comparing detailed economic calculations, including differences in pipe installation costs and construction costs, among others. A small solar-assisted district heating system has been modeled in TRNSYS based on a real system, and this “hybrid” model is used as a basis for a second model where a novel distribution system is employed and the heating network operating temperature is changed. Results indicate that a novel distribution concept with lower network temperatures and central domestic hot water preparation is most efficient both from an energy and cost perspective. The total life cycle costs vary less than 2% for a given distribution concept when using different pipe types and insulation classes, indicating that the investment costs are more significant than operational costs in reducing life cycle costs. The largest difference in life cycle cost is observed by changing the distribution concept, the novel concept having approximately 24% lower marginal life cycle cost than the “hybrid” system.

19 November 2024 in Energy Conversion and Management: X
Verified
Journal Article
Open access
MAMartin Andersen
Martin Andersen
CBChris Bales
Chris Bales
JDJan-Olof Dalenback
Jan-Olof Dalenback

31 July 2024 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
MAMartin Andersen
Martin Andersen
CBChris Bales
Chris Bales
JDJan-Olof Dalenbäck
Jan-Olof Dalenbäck
Most of the future district heating systems in the world are already in operation, using higher operating temperatures than those that are found in new-built systems, thought to make them less suited for renewable sources like solar heat. Regardless, installing a solar heating system may be a cost-effective measure to reduce biomass fuel use while enabling the use of the resources for other purposes. The main aim of this study was to determine whether or not adding solar heating to an existing district heating system can be cost-effective compared to a business-as-usual situation without solar. A secondary aim was to determine the cost-competitiveness of solar when adding solar at the same time as a boiler replacement. Other aims focused on the change in cost-competitiveness with change in economic boundary conditions, in addition to the potential impact of solar heating on unit heat cost due to reduced backup-boiler fuel use during prolonged maintenance. A theoretical district heating supply using a biomass boiler was modelled in TRNSYS based on an existing boiler-only system and load profile from a single year and this was used as a basis for model variations including storage and with or without solar heating. Results indicate that; Installing a slightly smaller boiler and storage is cost effective, regardless of whether solar heating is installed. Also, adding solar to an existing system is more or less always cost-effective and can give up to a 32% reduction in unit heat cost with a 13% solar fraction when using flat plate collectors. Using evacuated tube collectors is not as cost-effective, although the solar fraction becomes higher for a similarly sized system. When replacing the boiler, all system configurations have similar unit heat cost compared to a boiler-only system, so factors such as emission reductions due to solar heating are relevant when considering alternatives. Furthermore, increasing discount rate makes solar heating less cost-competitive compared to a boiler-only system, while a rise in fuel cost makes it more cost-competitive. Increasing solar collector area generally reduces backup-boiler fuel costs during maintenance, although simultaneously reduces the differences in unit heat cost between different fuel types due to lower overall fuel use.