Max von Witzleben

Mr. Max von Witzleben


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Anne BernhardtAnne Bernhardt
Anne Bernhardt
JSJasmin Skottke
Jasmin Skottke
MWMax von Witzleben
Max von Witzleben
Michael GelinskyMichael Gelinsky
Michael Gelinsky
In vitro evaluation of bone graft materials is generally performed by analyzing the interaction with osteoblasts or osteoblast precursors. In vitro bone models comprising different cell species can give specific first information on the performance of those materials. In the present study, a 3D co-culture model was established comprising primary human osteoblasts, osteoclasts and osteocytes. Osteocytes were differentiated from osteoblasts embedded in collagen gels and were cultivated with osteoblast and osteoclasts seeded in patterns on a porous membrane. This experimental setup allowed paracrine signaling as well as separation of the different cell types for final analysis. After 7 days of co-culture, the three cell species showed their typical morphology and gene expression of typical markers like ALPL, BSPII, BLGAP, E11, PHEX, MEPE, RANKL, ACP5, CAII and CTSK. Furthermore, relevant enzyme activities for osteoblasts (ALP) and osteoclasts (TRAP, CTSK, CAII) were detected. Osteoclasts in triple culture showed downregulated TRAP (ACP5) and CAII expression and decreased TRAP activity. ALP and BSPII expression of osteoblasts in triple culture were upregulated. The expression of the osteocyte marker E11 (PDPN) was unchanged; however, osteocalcin (BGLAP) expression was considerably downregulated both in osteoblasts and osteocytes in triple cultures compared to the respective single cultures.

Verified
Journal Article
Open access
PDF file
DKDavid Kilian
David Kilian
MWMax von Witzleben
Max von Witzleben
MLMatthew Lanaro
Matthew Lanaro
CWCynthia S. Wong
Cynthia S. Wong
CVCorina Vater
Corina Vater
Michael GelinskyMichael Gelinsky
Michael Gelinsky
The fabrication of patient-specific scaffolds for bone substitutes is possible through extrusion-based 3D printing of calcium phosphate cements (CPC) which allows the generation of structures with a high degree of customization and interconnected porosity. Given the brittleness of this clinically approved material, the stability of open-porous scaffolds cannot always be secured. Herein, a multi-technological approach allowed the simultaneous combination of CPC printing with melt electrowriting (MEW) of polycaprolactone (PCL) microfibers in an alternating, tunable design in one automated fabrication process. The hybrid CPC+PCL scaffolds with varying CPC strand distance (800–2000 µm) and integrated PCL fibers featured a strong CPC to PCL interface. While no adverse effect on mechanical stiffness was detected by the PCL-supported scaffold design; the microfiber integration led to an improved integrity. The pore distance between CPC strands was gradually increased to identify at which critical CPC porosity the microfibers would have a significant impact on pore bridging behavior and growth of seeded cells. At a CPC strand distance of 1600 µm, after 2 weeks of cultivation, the incorporation of PCL fibers led to pore coverage by a human mesenchymal stem cell line and an elevated proliferation level of murine pre-osteoblasts. The integrated fabrication approach allows versatile design adjustments on different levels.

9 September 2023 in Acta Biomaterialia
Verified
Journal Article
Open access
MWMax von Witzleben
Max von Witzleben
TSThomas Stoppe
Thomas Stoppe
AZAlina Zeinalova
Alina Zeinalova
ZCZhaoyu Chen
Zhaoyu Chen
TATilman Ahlfeld
Tilman Ahlfeld
Michael GelinskyMichael Gelinsky
Michael Gelinsky
The three additive manufacturing techniques fused deposition modeling, gel plotting and melt electrowriting were combined to develop a mimicry of the tympanic membrane (TM) to tackle large TM perforations caused by chronic otitis media. The mimicry of the collagen fiber orientation of the TM was accompanied by a study of multiple funnel-shaped mimics of the TM morphology, resulting in mechanical and acoustic properties similar to those of the eardrum. For the different 3D printing techniques used, the process parameters were optimized to allow reasonable microfiber arrangements within the melt electrowriting setup. Interestingly, the fiber pattern was less important for the acousto-mechanical properties than the overall morphology. Furthermore, the behavior of keratinocytes and fibroblasts is crucial for the repair of the TM, and an in vitro study showed a high biocompatibility of both primary cell types while mimicking the respective cell layers of the TM. A simulation of the in vivo ingrowth of both cell types resulted in a cell growth orientation similar to the original collagen fiber orientation of the TM. Overall, the combined approach showed all the necessary parameters to support the growth of a neo-epithelial layer with a similar structure and morphology to the original membrane. It therefore offers a suitable alternative to autologous materials for the treatment of chronic otitis media. STATEMENT OF SIGNIFICANCE: Millions of people worldwide suffer from chronic middle ear infections. Although the tympanic membrane (TM) can be reconstructed with autologous materials, the grafts used for this purpose require extensive manual preparation during surgery. This affects not only the hearing ability but also the stability of the reconstructed TM, especially in the case of full TM reconstruction. The synthetic alternative presented here mimicked not only the fibrous structure of the TM but also its morphology, resulting in similar acousto-mechanical properties. Furthermore, its high biocompatibility supported the migration of keratinocytes and fibroblasts to form a neo-epithelial layer. Overall, this completely new TM replacement was achieved by combining three different additive manufacturing processes.

7 August 2025 in Advanced Healthcare Materials
Verified
Journal Article
Open access
MWMax von Witzleben
Max von Witzleben
AGAkvilė Gasiūnaitė
Akvilė Gasiūnaitė
MIMarlene Ihle
Marlene Ihle
AAAshwini Rahul Akkineni
Ashwini Rahul Akkineni
KSKathleen Schütz
Kathleen Schütz
SDSarah Duin
Sarah Duin
The development of mechanically robust, cell‐instructive, and seweable small‐diameter (≤ Ø 6 mm) tubular scaffolds remain a major challenge in vascular tissue engineering. Here, a hybrid biofabrication strategy is presented that combines 4D printing of alginate‐methylcellulose (AlgMC) hydrogels with melt electrowritten (MEW) poly(ε‐caprolactone) (PCL) reinforcement to produce tubular constructs with programmable shape‐morphing capacity. The MEW fiber meshes significantly improve mechanical integrity, enabling suturing and perfusion, while preserving the anisotropic swelling behavior required for morphogenesis. Scaffold functionalization using human blood‐derived protein coatings — such as fresh frozen plasma, platelet lysate, and fibrinogen — markedly enhances cellular adhesion and fibroblast proliferation without compromising structural transformation. Biological evaluation using mono and co‐cultures of fibroblasts, endothelial cells (HUVEC), and vascular smooth muscle cells (vSMC) reveals the formation of organized bi‐layers and phenotype‐specific cell morphologies on AlgMC/PCL composites. Notably, a confluent endothelial layer promotes contractile marker expression in vSMC, while vSMC support endothelial coverage in the absence of a growth‐arrested fibroblast feeder layer, indicating reciprocal stabilization. While further optimization is needed to meet the demands of small‐diameter vascular grafts fully, the presented system offers a versatile and promising platform for engineering soft tissue constructs that benefit from topographical guidance, spatially controlled adhesion, and adaptive geometry.

13 May 2025 in Materials Today Bio
Verified
Journal Article
Open access
MWMax von Witzleben
Max von Witzleben
SLSuihong Liu
Suihong Liu
PSPhilipp Sembdner
Philipp Sembdner
SHStefan Holtzhausen
Stefan Holtzhausen
SBSophia Freya Ulrike Blum
Sophia Freya Ulrike Blum
HBHenriette Bretschneider
Henriette Bretschneider
Ideally, the combination of clinical imaging techniques with additive manufacturing processes enables the fabrication of patient-specific regenerative implants that precisely fit into the defect site, promoting native tissue restoration while gradually degrading. Osteochondral defects, affecting both cartilage and subchondral bone in joints are best visualized using magnetic resonance imaging (MRI). In this study, a workflow for computer-aided manufacturing of patient-specific osteochondral implants based on geometrical data obtained from MRI scans was evaluated in a clinically relevant setting. Artificial osteochondral defects were created in femoral condyles of human body donors and scanned with MRI. ‘Computer-Aided Design’ (CAD) models for bone and cartilage components served as basis for designing defect-specific trizonal implants consisting of (i) a bone, (ii) an interlocking, and (iii) a cartilage zone. These implants were fabricated using multi-channel 3D extrusion printing, using a calcium phosphate cement as a bone substitute and an alginate-based hydrogel as a cartilage substitute material - with both materials alternately printed in the interlocking zone. After fabrication, the constructs were implanted into the corresponding defects, and assessed for fit accuracy via clinical imaging. The entire process chain was successfully conducted under near-clinical conditions by an interdisciplinary team of engineers, radiologist and surgeons, during which critical points were identified. Due to the inherent resolution limitations of clinical MRI and extrusion-based 3D printing, inaccuracies in implant fitting occurred; strategies to address these challenges were identified by integrating design tolerances and applying minor intraoperative adjustments.

1 January 2026 in Bioactive Materials
Verified
Journal Article
Open access
YLYakui Liu
Yakui Liu
MWMax von Witzleben
Max von Witzleben
SDSarah Duin
Sarah Duin
Anne BernhardtAnne Bernhardt
Anne Bernhardt
Michael GelinskyMichael Gelinsky
Michael Gelinsky
Abdominal wall patches are clinically essential for treating abdominal defects or hernias, with mechanical strength representing a critical requirement. Therefore, rational scaffold design and fabrication methods are crucial for achieving optimal performance. This study introduces an innovative approach to the design of scaffolds for abdominal wall repair, using topology optimization and melt electrowriting (MEW). Through topology optimization, we provided a systematic, data-driven basis for scaffold design. We further refined the scaffold structure to enhance print efficiency and continuity, and successfully implemented MEW as fabrication technology, marking its first application in abdominal repair. Mechanical testing revealed that the topology-optimized scaffold achieved abdominal tensile strength of 1.85 ± 0.02 N/cm, 39 % superior to conventional designs. Subsequent biological assessments – including fibroblast proliferation and alignment analyses – showed that collagen coating significantly enhanced cell attachment and proliferation, especially in multi-layer (300 layers) scaffolds, maintaining diameters of 11.34 ± 0.67 μm throughout the depth. Finally, ex vivo porcine abdominal wall tests confirmed clinical mechanical suitability. This work offers a promising direction for future advancements in tissue engineering, particularly in optimizing scaffold structures for biological and mechanical performance.