We investigated low-latitude ionospheric scintillation in Indonesia using two GPS receivers installed at Bandung (107.6° E, 6.9° S; magnetic latitude 17.5° S) and Pontianak (109.3° E, 0.02° S; magnetic latitude 8.9° S). This study aimed to characterise climatological and directional ionospheric scintillation occurrences, which are useful not only for the physics of ionospheric irregularities but also for practical use in GNSS (global navigation satellite system)-based navigation. We used the deployed instrument's amplitude scintillation (S4 index) data from 2009, 2010, and 2011; the yearly SSN (sunspot-smoothed numbers) were 3.1, 16.5, and 55.9, respectively. In summary, (1) scintillation occurrences in the post-sunset period (18:00–01:00 LT) during equinox months (plasma bubble season) at the two sites can be ascribed to the plasma bubble; (2) using directional analyses of the two sites, we found that the distribution of scintillation occurrences is generally concentrated between the two sites, indicating the average location of the EIA (equatorial ionisation anomaly) crest; (3) scintillation occurrence enhancements for the two sites in field-aligned directions are herein reported for the first time by ground-based observation in a low-latitude region; (4) distribution of scintillation occurrences at Pontianak are concentrated in the southern sky, especially in the southwest direction, which is very likely associated with the plasma bubble tilted westward with increasing latitude; and (5) scintillation occurrence in the post-midnight period in the non-plasma-bubble season is the most intriguing variable occurring between the two sites (i.e. post-midnight scintillations are observed more at Bandung than Pontianak). Most of the post-midnight scintillations observed at Bandung are concentrated in the northern sky, with low elevation angles. This might be due to the amplitude of irregularities in certain directions, which may be effectively enhanced by background density enhancement by the EIA and because satellite–receiver paths are longer in the EIA crest region and in a field-aligned direction.
Limboto Lake—Pentadio area is located in the province of Gorontalo on the northern arm of Sulawesi Island, Indonesia, which experienced a tectonic process from the Sula Platform collision in the mid-Miocene. This tectonic process led to the westward subduction of the early Miocene and post-collision rifting and uplifting of the arc and subduction along the North Sulawesi Trench during the Late Miocene to the Quaternary periods. The rifting process of the North Sulawesi arc resulted in the formation of the Gorontalo graben zone in the W–E direction. There are geothermal surface manifestations near Limboto Lake, such as hot spring complexes, with temperatures ranging from 74.8 °C to 78.5 °C. To understand the geological structure and prospective geothermal characteristics beneath the investigated area, we performed integrated magnetotelluric and gravity surveys. The preferred 3D resistivity model confirmed the presence of a fault system and a graben system that was filled with conductive bodies (~1–15 Ωm) corresponding to alluvium deposits. This result was in accordance with the 2D density model inferred from the gravity data, where a low-density value indicates the presence of a graben zone. The conceptual model of Limboto Lake—Pentadio was constructed using the information from the MT and gravity results, and from the geological study. The conceptual model illustrates the geothermal system in Limboto Lake—Pentadio, which is controlled by the fault system and the Gorontalo graben system.
Studies pertaining to heat flow density distribution in Indonesian tertiary sedimentary basins have been conducted intermittently throughout more than two decades. Even so, all of these studies have always concentrated on the basic compilations of thermal gradient, thermal conductivity, and terrestrial heat flow datasets or the study of basin thermal history rather than on the investigations into their present thermal regime. In addition, syntheses on the possible causes to the observed heat flow density distribution in these basins have been largely determined only on the basis of its correlation with geological and geophysical evidences. One basin experiencing this particular problem is the onshore Northwest Java Basin, where knowledge of the present-day subsurface temperature structure is virtually absent and interpretation of heat flow distribution has been mainly qualitative. For these reasons, in this study we have attempted to quantitatively characterize the present subsurface temperature distribution and surface heat flow density of the onshore Northwest Java Basin using a simple numerical thermal modeling approach, based on the most recent heat flow datasets. Taking into account a conductive heat transfer process, the modeling exercise is aimed at deriving a 3-D subsurface temperature distribution. The temperature distribution is translated into the predicted surface heat flow distribution. The modeled temperature field reveals its dependence on the geometrical aspects of the basin’s basement. Comparison between the computed and the observed heat flow densities, taking into account the uncertainties of both, suggests that advective heat transport by groundwater flow may be present, in addition to conduction. The modeling results are thus capable of demonstrating the importance of a quantitative approach in studying the present thermal state of a sedimentary basin.