Tero Koivisto

Dr. Tero Koivisto


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2019 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
MKMatti Kaisti
Matti Kaisti
TPTuukka Panula
Tuukka Panula
JLJoni Leppänen
Joni Leppänen
RPRisto Punkkinen
Risto Punkkinen
MJMojtaba Jafaritadi
Mojtaba Jafaritadi
MPMikko Pänkäälä
Mikko Pänkäälä
There is an unmet clinical need for a low cost and easy to use wearable devices for continuous cardiovascular health monitoring. A flexible and wearable wristband, based on microelectromechanical sensor (MEMS) elements array was developed to support this need. The performance of the device in cardiovascular monitoring was investigated by (i) comparing the arterial pressure waveform recordings to the gold standard, invasive catheter recording (n = 18), (ii) analyzing the ability to detect irregularities of the rhythm (n = 7), and (iii) measuring the heartrate monitoring accuracy (n = 31). Arterial waveforms carry important physiological information and the comparison study revealed that the recordings made with the wearable device and with the gold standard device resulted in almost identical (r = 0.9–0.99) pulse waveforms. The device can measure the heart rhythm and possible irregularities in it. A clustering analysis demonstrates a perfect classification accuracy between atrial fibrillation (AF) and sinus rhythm. The heartrate monitoring study showed near perfect beat-to-beat accuracy (sensitivity = 99.1%, precision = 100%) on healthy subjects. In contrast, beat-to-beat detection from coronary artery disease patients was challenging, but the averaged heartrate was extracted successfully (95% CI: −1.2 to 1.1 bpm). In conclusion, the results indicate that the device could be useful in remote monitoring of cardiovascular diseases and personalized medicine.

1 January 2014 in International Journal of Biomedical Imaging
Verified
Journal Article
Open access
PDF file
MJMojtaba Jafaritadi
Mojtaba Jafaritadi
TKTero Koivisto
Tero Koivisto
MPMikko Pänkäälä
Mikko Pänkäälä
APAri Paasio
Ari Paasio
Both respiratory and cardiac motions reduce the quality and consistency of medical imaging specifically in nuclear medicine imaging. Motion artifacts can be eliminated by gating the image acquisition based on the respiratory phase and cardiac contractions throughout the medical imaging procedure. Electrocardiography (ECG), 3-axis accelerometer, and respiration belt data were processed and analyzed from ten healthy volunteers. Seismocardiography (SCG) is a noninvasive accelerometer-based method that measures accelerations caused by respiration and myocardial movements. This study was conducted to investigate the feasibility of the accelerometer-based method in dual gating technique. The SCG provides accelerometer-derived respiratory (ADR) data and accurate information about quiescent phases within the cardiac cycle. The correct information about the status of ventricles and atria helps us to create an improved estimate for quiescent phases within a cardiac cycle. The correlation of ADR signals with the reference respiration belt was investigated using Pearson correlation. High linear correlation was observed between accelerometer-based measurement and reference measurement methods (ECG and Respiration belt). Above all, due to the simplicity of the proposed method, the technique has high potential to be applied in dual gating in clinical cardiac positron emission tomography (PET) to obtain motion-free images in the future.

26 November 2018 in IEEE Sensors Journal
Verified
Journal Article
Open access
MJMojtaba Jafaritadi
Mojtaba Jafaritadi
SMSaeed Mehrang
Saeed Mehrang
MKMatti Kaisti
Matti Kaisti
OLOlli Lahdenoja
Olli Lahdenoja
THTero Hurnanen
Tero Hurnanen
MPMikko Pankaala
Mikko Pankaala
Atrial fibrillation (AFib) is the most common sustained heart arrhythmia and is characterized by irregular and excessively frequent ventricular contractions. Early diagnosis of AFib is a key step in the prevention of stroke and heart failure. In this study, we present a comprehensive time-frequency pattern analysis approach for automated detection of AFib from smartphone-derived seismocardiography (SCG) and gyrocardiography (GCG) signals. We sought to assess the diagnostic performance of a smartphone mechanocardiogram (MCG) by considering joint SCG-GCG recordings from 435 subjects including 190 AFib and 245 sinus rhythm (SR) cases. A fully automated AFib detection algorithm consisting of various signal processing and multidisciplinary feature engineering techniques was developed and evaluated through a large set of cross-validation (CV) data including 300 (AFib=150) cardiac patients. The trained model was further tested on an unseen set of recordings including 135 (AFib=40) subjects considered as cross-database (CD). The experimental results showed accuracy, sensitivity, and specificity of approximately 97%, 99%, and 95% for the CV study and up to 95%, 93%, and 97% for the CD test, respectively. The F1 scores were 97% and 96% for the CV and CD, respectively. A positive predictive value of approximately 95% and 92% was obtained respectively for the validation and test sets suggesting high reproducibility and repeatability for mobile AFib detection. Moreover, the kappa coefficient of the method was 0.94 indicating a near-perfect agreement in rhythm classification between the smartphone algorithm and visual interpretation of telemetry recordings. The results support the feasibility of self-monitoring via easy-to-use and accessible MCGs.

17 March 2020 in IEEE Sensors Journal
Verified
Journal Article
Open access
SMSaeed Mehrang
Saeed Mehrang
OLOlli Lahdenoja
Olli Lahdenoja
MKMatti Kaisti
Matti Kaisti
MJMojtaba Jafaritadi
Mojtaba Jafaritadi
THTero Hurnanen
Tero Hurnanen
MPMikko Pankaala
Mikko Pankaala
Timely diagnosis of cardiovascular diseases (CVD) is crucial to prevent morbidity and mortality. Atrial fibrillation (AFib) and heart failure (HF) are two prevalent cardiac disorders that are associated with a high risk of morbidity and mortality, especially if they are concurrently present. Current approaches fail to screen many at-risk individuals who would benefit from preventive treatment; while others receive unnecessary interventions. An effective approach to the detection of CVDs is mechanocardiography (MCG) by which translational and rotational precordial chest movements are monitored. In this study, we collected MCG data from a study sample of 300 hospitalized cardiac patients using multidimensional built-in inertial sensors of a smartphone. Our main objective was to detect concurrent AFib and acute decompensated HF (ADHF) using smartphone MCG (or sMCG). To this end, we adopted a supervised machine learning classification using multi-label and hierarchical classification. Logistic regression, random forest, and extreme gradient boosting were used as candidate classifiers. The results of the analysis showed the area under the receiver operating characteristic curve values of 0.98 and 0.85 for AFib and ADHF, respectively. The highest percentages of positive and negative predictive values for AFib were 91.9 and 100; while for ADHF, they were 56.9 and 88.4 for the multi-label classification and 69.9 and 68.8 for the hierarchical classification, respectively. We conclude that using a single sMCG measurement, AFib can be detected accurately whereas ADHF can be detected with moderate certainty.

9 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
TKTero Koivisto
Tero Koivisto
OLOlli Lahdenoja
Olli Lahdenoja
THTero Hurnanen
Tero Hurnanen
TVTuija Vasankari
Tuija Vasankari
SJSamuli Jaakkola
Samuli Jaakkola
JAJuhani Airaksinen
Juhani Airaksinen
Novel means to minimize treatment delays in patients with ST elevation myocardial infarction (STEMI) are needed. Using an accelerometer and gyroscope on the chest yield mechanocardiographic (MCG) data. We investigated whether STEMI causes changes in MCG signals which could help to detect STEMI. The study group consisted of 41 STEMI patients and 49 control patients referred for elective coronary angiography and having normal left ventricular function and no valvular heart disease or arrhythmia. MCG signals were recorded on the upper sternum in supine position upon arrival to the catheterization laboratory. In this study, we used a dedicated wearable sensor equipped with 3-axis accelerometer, 3-axis gyroscope and 1-lead ECG in order to facilitate the detection of STEMI in a clinically meaningful way. A supervised machine learning approach was used. Stability of beat morphology, signal strength, maximum amplitude and its timing were calculated in six axes from each window with varying band-pass filters in 2–90 Hz range. In total, 613 features were investigated. Using logistic regression classifier and leave-one-person-out cross validation we obtained a sensitivity of 73.9%, specificity of 85.7% and AUC of 0.857 (SD = 0.005) using 150 best features. As a result, mechanical signals recorded on the upper chest wall with the accelerometers and gyroscopes differ significantly between STEMI patients and stable patients with normal left ventricular function. Future research will show whether MCG can be used for the early screening of STEMI.

13 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
TKTero Koivisto
Tero Koivisto
OLOlli Lahdenoja
Olli Lahdenoja
THTero Hurnanen
Tero Hurnanen
JKJuho Koskinen
Juho Koskinen
KJKamal Jafarian
Kamal Jafarian
JAJuhani Airaksinen
Juhani Airaksinen
Heart failure (HF) is a disease related to impaired performance of the heart and is a significant cause of mortality and treatment costs in the world. During its progression, HF causes worsening (decompensation) periods which generally require hospital care. In order to reduce the suffering of the patients and the treatment cost, avoiding unnecessary hospital visits is essential, as hospitalization can be prevented by medication. We have developed a data-collection device that includes a high-quality 3-axis accelerometer and 3-axis gyroscope and a single-lead ECG. This allows gathering ECG synchronized data utilizing seismo- and gyrocardiography (SCG, GCG, jointly mechanocardiography, MCG) and comparing the signals of HF patients in acute decompensation state (hospital admission) and compensated condition (hospital discharge). In the MECHANO-HF study, we gathered data from 20 patients, who each had admission and discharge measurements. In order to avoid overfitting, we used only features developed beforehand and selected features that were not outliers. As a result, we found three important signs indicating the worsening of the disease: an increase in signal RMS (root-mean-square) strength (across SCG and GCG), an increase in the strength of the third heart sound (S3), and a decrease in signal stability around the first heart sound (S1). The best individual feature (S3) alone was able to separate the recordings, giving 85.0% accuracy and 90.9% accuracy regarding all signals and signals with sinus rhythm only, respectively. These observations pave the way to implement solutions for patient self-screening of the HF using serial measurements.