Background - COVID-19 has led to over 1 million deaths worldwide and has been associated with cardiac complications including cardiac arrhythmias. The incidence and pathophysiology of these manifestations remain elusive. In this worldwide survey of patients hospitalized with COVID-19 who developed cardiac arrhythmias, we describe clinical characteristics associated with various arrhythmias, as well as global differences in modulations of routine electrophysiology practice during the pandemic. Methods - We conducted a retrospective analysis of patients hospitalized with COVID-19 infection worldwide with and without incident cardiac arrhythmias. Patients with documented atrial fibrillation (AF), atrial flutter (AFL), supraventricular tachycardia (SVT), non-sustained or sustained ventricular tachycardia (VT), ventricular fibrillation (VF), atrioventricular block (AVB), or marked sinus bradycardia (HR<40bpm) were classified as having arrhythmia. De-identified data was provided by each institution and analyzed. Results - Data was collected for 4,526 patients across 4 continents and 12 countries, 827 of whom had an arrhythmia. Cardiac comorbidities were common in patients with arrhythmia: 69% had hypertension, 42% diabetes mellitus, 30% had heart failure and 24% coronary artery disease. Most had no prior history of arrhythmia. Of those who did develop an arrhythmia, the majority (81.8%) developed atrial arrhythmias, 20.7% developed ventricular arrhythmias, and 22.6% had bradyarrhythmia. Regional differences suggested a lower incidence of AF in Asia compared to other continents (34% vs. 63%). Most patients in in North America and Europe received hydroxychloroquine, though the frequency of hydroxychloroquine therapy was constant across arrhythmia types. Forty-three percent of patients who developed arrhythmia were mechanically ventilated and 51% survived to hospital discharge. Many institutions reported drastic decreases in electrophysiology procedures performed. Conclusions - Cardiac arrhythmias are common and associated with high morbidity and mortality among patients hospitalized with COVID-19 infection. There were significant regional variations in the types of arrhythmias and treatment approaches.
21 September 2021 in Journal of the American Heart Association
Criteria for diagnosis of arrhythmogenic cardiomyopathy (ACM) were first proposed in 1994 and revised in 2010 by a Task Force. Although the Task Force criteria demonstrated a good accuracy for diagnosis of the original right ventricular phenotype (arrhythmogenic right ventricular cardiomyopathy), they lacked sensitivity for identification of the expanding phenotypic spectrum of ACM, which includes left‐sided variants and did not incorporate late‐gadolinium enhancement findings by cardiac magnetic resonance. The 2020 International criteria (“Padua criteria”) have been developed by International experts with the aim to improve the diagnosis of ACM by providing new criteria for the diagnosis of left ventricular phenotypic features. The key upgrade was the incorporation of tissue characterization findings by cardiac magnetic resonance for noninvasive detection of late‐gadolinium enhancement/myocardial fibrosis that are determinants for characterization of arrhythmogenic biventricular and left ventricular cardiomyopathy. The 2020 International criteria are heavily dependent on cardiac magnetic resonance, which has become mandatory to characterize the ACM phenotype and to exclude other diagnoses. New criteria regarding left ventricular depolarization and repolarization ECG abnormalities and ventricular arrhythmias of left ventricular origin were also provided. This article reviews the evolving approach to diagnosis of ACM, going back to the 1994 and 2010 International Task Force criteria and then grapple with the modern 2020 International criteria.
29 July 2014 in Pacing and Clinical Electrophysiology
Background: The traditional technique for subcutaneous implantable cardioverter defibrillator (S‐ICD) implantation, which involves three incisions and a subcutaneous pocket, is associated with possible complications, including inappropriate interventions. The aim of this prospective multicenter study was to evaluate the efficacy and safety of an alternative intermuscular two‐incision technique for S‐ICD implantation.Methods: The study population included 36 consecutive patients (75% male, mean age 44 ± 12 years [range 20–69]) who underwent S‐ICD implantation using the intermuscular two‐incision technique. This technique avoids the superior parasternal incision for the lead placement and consists of creating an intermuscular pocket between the anterior surface of the serratus anterior and the posterior surface of the latissimus dorsi muscles instead of a subcutaneous pocket.Results: All patients were successfully implanted in the absence of any procedure‐related complications with a successful 65‐J standard polarity defibrillation threshold testing, except in one, who received a second successful shock after pocket revision. During a mean follow‐up of 10 months (range 3–30), no complications requiring surgical revision were observed. At device interrogation, stable sensing without interferences was observed in all patients. Two patients (5.5%) experienced appropriate and successful shock on ventricular fibrillation and in four patients (11%), a total of seven nonsustained self‐terminated ventricular tachycardias were correctly detected. No inappropriate interventions were observed.Conclusions: Our experience suggests that the two‐incision intermuscular technique is a safe and efficacious alternative to the current technique for S‐ICD implantation that may help reducing complications including inappropriate interventions and offer a better cosmetic outcome, especially in thin individuals.
The aim of this prospective multicentre study is to evaluate safety and efficacy of the new bidirectional rotational mechanical lead extraction (LE) sheath (Evolution RL, Cook Medical, USA) in chronically implanted leads (>1-year-old leads). Between September 2013 and June 2016, a total of 238 leads in 124 consecutive patients were removed by using the new Evolution RL rotational mechanical sheath. Indications for LE were cardiac device infection in 63 (50.8%) cases, lead malfunction in 41 (33.1%), upgrade in 1 (0.8%) case and for other reasons in the remaining 19 cases (15.3%). Ninety-one leads (38.2%) were implantable cardioverter defibrillator leads (81 dual coil vs. 10 single coil), 38 (16%) right ventricular leads, 86 (36.1%) right atrial leads, and 23 (9.7%) coronary sinus leads. The mean implant duration was 92.2 ± 52.9 months (range 12–336). 91.6% of the leads (218/238) were extracted completely with the Evolution RL alone, with the complete success rate rising to 98.7% (235/238 leads) with combined use of a snare. Overall clinical success rate was 100%. No Evolution sheath-related complications were noted. There were no deaths or major complications. Five minor complications (4%) were encountered. In cases of companion leads no wrapping or lead damage were observed. On the basis of our prospective multicentre study, the new hand-powered bidirectional rotational mechanical LE sheath is an effective and safe tool for the extraction of chronically implanted leads without major complications and lead wrapping or lead damage.