Viktor Zoltán Jónás

Mr. Viktor Zoltán Jónás

Image Analysis Department, 3DHISTECH Ltd., Budapest, Hungary
+1
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2011 in Diagnostic Pathology
Verified
Journal Article
Open access
PDF file
LKLászló Krecsák
László Krecsák
TMTamás Micsik
Tamás Micsik
GKGábor Kiszler
Gábor Kiszler
Tibor KrenacsTibor Krenacs
Tibor Krenacs
DSDániel Szabó
Dániel Szabó
BMBéla Molnár
Béla Molnár
Background: The immunohistochemical detection of estrogen (ER) and progesterone (PR) receptors in breast cancer is routinely used for prognostic and predictive testing. Whole slide digitalization supported by dedicated software tools allows quantization of the image objects (e.g. cell membrane, nuclei) and an unbiased analysis of immunostaining results. Validation studies of image analysis applications for the detection of ER and PR in breast cancer specimens provided strong concordance between the pathologist's manual assessment of slides and scoring performed using different software applications. Methods: The effectiveness of two connected semi-automated image analysis software (NuclearQuant v. 1.13 application for Pannoramic™ Viewer v. 1.14) for determination of ER and PR status in formalin-fixed paraffin embedded breast cancer specimens immunostained with the automated Leica Bond Max system was studied. First the detection algorithm was calibrated to the scores provided an independent assessors (pathologist), using selected areas from 38 small digital slides (created from 16 cases) containing a mean number of 195 cells. Each cell was manually marked and scored according to the Allred-system combining frequency and intensity scores. The performance of the calibrated algorithm was tested on 16 cases (14 invasive ductal carcinoma, 2 invasive lobular carcinoma) against the pathologist's manual scoring of digital slides. Results: The detection was calibrated to 87 percent object detection agreement and almost perfect Total Score agreement (Cohen's kappa 0.859, quadratic weighted kappa 0.986) from slight or moderate agreement at the start of the study, using the un-calibrated algorithm. The performance of the application was tested against the pathologist's manual scoring of digital slides on 53 regions of interest of 16 ER and PR slides covering all positivity ranges, and the quadratic weighted kappa provided almost perfect agreement (κ = 0.981) among the two scoring schemes. Conclusions: NuclearQuant v. 1.13 application for Pannoramic™ Viewer v. 1.14 software application proved to be a reliable image analysis tool for pathologists testing ER and PR status in breast cancer.

14 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
VJViktor Zoltán Jónás
Viktor Zoltán Jónás
Róbert PaulikRóbert Paulik
Róbert Paulik
MKMiklos Kozlovszky
Miklos Kozlovszky
BMBéla Molnár
Béla Molnár
Ploidy analysis is the fundamental method of measuring DNA content. For decades, the principal way of conducting ploidy analysis was through flow cytometry. A flow cytometer is a specialized tool for analyzing cells in a solution. This is convenient in laboratory environments, but prohibits measurement reproducibility and the complete detachment of sample preparation from data acquisition and analysis, which seems to have become paramount with the constant decrease in the number of pathologists per capita all over the globe. As more open computer-aided systems emerge in medicine, the demand for overcoming these shortcomings, and opening access to even more (and more flexible) options, has also emerged. Image-based analysis systems can provide an alternative to these types of workloads, placing the abovementioned problems in a different light. Flow cytometry data can be used as a reference for calibrating an image-based system. This article aims to show an approach to constructing an image-based solution for ploidy analysis, take measurements for a basic comparison of the data produced by the two methods, and produce a workflow with the ultimate goal of calibrating the image-based system.

17 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
DKDániel Küttel
Dániel Küttel
LKLászló Kovács
László Kovács
ÁSÁkos Szölgyén
Ákos Szölgyén
Róbert PaulikRóbert Paulik
Róbert Paulik
VJViktor Zoltán Jónás
Viktor Zoltán Jónás
BMBéla Molnár
Béla Molnár
As the field of routine pathology transitions into the digital realm, there is a surging demand for the full automation of microscope scanners, aiming to expedite the process of digitizing tissue samples, and consequently, enhancing the efficiency of case diagnoses. The key to achieving seamless automatic imaging lies in the precise detection and segmentation of tissue sample regions on the glass slides. State-of-the-art approaches for this task lean heavily on deep learning techniques, particularly U-Net convolutional neural networks. However, since samples can be highly diverse and prepared in various ways, it is almost impossible to be fully prepared for and cover every scenario with training data. We propose a data augmentation step that allows artificially modifying the training data by extending some artifact features of the available data to the rest of the dataset. This procedure can be used to generate images that can be considered synthetic. These artifacts could include felt pen markings, speckles of dirt, residual bubbles in covering glue, or stains. The proposed approach achieved a 1–6% improvement for these samples according to the F1 Score metric.

28 March 2015
Verified
Book Chapter
Open access
PDF file
VJViktor Zoltán Jónás
Viktor Zoltán Jónás
MKMiklos Kozlovszky
Miklos Kozlovszky
BMBéla Molnár
Béla Molnár
Cancer research and diagnostics is an important frontier to apply the power of computers. Researchers use image processing techniques for a few years now, but diagnostics only start to explore its possibilities. Pathologists specialized in this area usually diagnose by visual inspection, typically through a microscope, or more recently on a computer screen. They examine at tissue specimen or a sample consisting of a population cells extracted from it. The latter area is the area of cytometry that researchers started to support by creating image processing algorithms. The validation of an image processing approach like that is an expensive task both financially and time-wise. This paper aims to show a semi-automatized method to simplify this task, by reducing the amount of human interaction necessary.

26 September 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VJViktor Zoltán Jónás
Viktor Zoltán Jónás
Róbert PaulikRóbert Paulik
Róbert Paulik
BMBéla Molnár
Béla Molnár
MKMiklos Kozlovszky
Miklos Kozlovszky
Digitization in pathology and cytology labs is now widespread, a significant shift from a decade ago when few doctors used image processing tools. Despite unchanged scanning times due to excitation in fluorescent imaging, advancements in computing power and software have enabled more complex algorithms, yielding better-quality results. This study evaluates three nucleus segmentation algorithms for ploidy analysis using propidium iodide-stained digital WSI slides. Our goal was to improve segmentation accuracy to more closely match DNA histograms obtained via flow cytometry, with the ultimate aim of enhancing the calibration method we proposed in a previous study, which seeks to align image cytometry results with those from flow cytometry. We assessed these algorithms based on raw segmentation performance and DNA histogram similarity, using confusion-matrix-based metrics. Results indicate that modern algorithms perform better, with F1 scores exceeding 0.845, compared to our earlier solution’s 0.807, and produce DNA histograms that more closely resemble those from the reference FCM method.

8 November 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VJViktor Zoltán Jónás
Viktor Zoltán Jónás
DKDániel Küttel
Dániel Küttel
BMBéla Molnár
Béla Molnár
MKMiklos Kozlovszky
Miklos Kozlovszky
Reliable evaluation of image segmentation algorithms in digital pathology depends on high-quality annotation datasets. Landmark-type annotations, essential for cell-counting analyses, are often limited in quality or quantity for segmentation benchmarking, particularly in rare assays where annotation is scarce and costly. In this study, we investigate whether ensemble-inspired refinement of landmark annotations can improve the robustness of segmentation evaluation. Using 15 fluorescently imaged blood samples with more than 20,000 manually placed annotations, we compared three segmentation algorithms—a threshold-based method with clump splitting, a difference-of-Gaussians (DoG) approach, and a convolutional neural network (StarDist)—and used their combined outputs to generate an ensemble-derived ground truth. Confusion matrices and standard metrics (F1 score, precision, and sensitivity) were computed against both manual and ensemble-derived ground truths. Statistical comparisons showed that ensemble-refined annotations reduced noise and decreased mean offsets between annotations and detected objects, yielding more stable evaluation metrics. Our results demonstrate that ensemble-based ground truth generation can guide targeted revision of manual markers, provide a quality measure for annotation reliability, and generate new annotations where no human-generated landmarks exist. This methodology offers a generalizable strategy to strengthen annotation datasets in image cytometry, enabling robust algorithm evaluation in DNA ploidy analysis and potentially in other low-frequency assays.